ABB 1SVR730784R3300 1SVR730784R3300 ABB CM-PSS.41S Three-phase monitoring relay 2c/o, 0,0.1-30s, L1-L2-L3 3x400VAC View larger
Images are for illustrative purposes only. Please refer to data sheet for details

1SVR730784R3300 ABB CM-PSS.41S Three-phase monitoring relay 2c/o, 0,0.1-30s, L1-L2-L3 3x400VAC

1SVR730784R3300

730784

ABB

1 Pcs.

CM-PSS.41S Three-phase monitoring relay 2c/o, 0,0.1-30s, L1-L2-L3=3x400VAC CM-PSS.41S RELe CTRL THREE-PHASE 2 C/C TOR

Automation > Phase monitoring relay
Monitoring

Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.

Request a Quote

Pricing and availability are confirmed for each enquiry. Add your required quantity to begin.

No account, online checkout or payment is required.

More info

Ordering
EAN4016779851824
Minimum Order Quantity1 piece
Customs Tariff Number85364900
Popular Downloads
Data Sheet, Technical Information2CDC112178D0201
Instructions and Manuals1SVC730730M1000
1SVC730730M0000
CAD Dimensional Drawing2CDC001079B0201
EPLAN Data9AAC132605_EPLAN
Dimensions
Product Net Width22.5 mm
Product Net Height85.6 mm
Product Net Depth / Length103.7 mm
Product Net Weight0.132 kg
Technical
FunctionPhase failure detection
Phase sequence monitoring
Over- and undervoltage monitoring
Measuring Range(L-L) 360 ... 440 V AC
Time RangeTripping Delay (ON or OFF) 0 second [unit of time]
Rated Control Supply Voltage (Us)(L-L) 400 V AC
Rated Frequency (f)Supply Circuit 50/60 Hz
Output2 C/O Contacts
Terminal TypeScrew Terminals
Rated Operational Current AC-12 (Ie)(230 V) 4 A
Rated Operational Current AC-15 (Ie)(230 V) 3 A
Rated Operational Current DC-12 (Ie)(24 V) 4 A
Rated Operational Current DC-13 (Ie)(24 V) 2 A
Minimum Switching Capacity24 V
10 mA
Rated Impulse Withstand Voltage (Uimp)Input Circuit 6 kV
Output Circuit 4 kV
Rated Insulation Voltage (Ui)Input Circuit / Output Circuit 600 V
Output Circuit 1 / Output Circuit 2 300 V
Degree of ProtectionHousing IP50
Terminals IP20
Overvoltage CategoryIII
Pollution Degree3
Short-Circuit Protective DevicesOutput Circuit NC - F Type Fuses 6 A
Output Circuit NO - F Type Fuses 10 A
Electrical DurabilityAC-12 100000 cycle
Mechanical DurabilityNr. Operations 30000000 cycle
Connecting CapacityFlexible with Ferrule 1x 0.5 ... 2.5 mm²
Flexible with Ferrule 2x 0.5 ... 1.5 mm²
Flexible with Insulated Ferrule 1x 0.5 ... 2.5 mm²
Flexible with Insulated Ferrule 2x 0.5 ... 1.5 mm²
Flexible 1x 0.5 ... 2.5 mm²
Flexible 2x 0.5 ... 1.5 mm²
Rigid 1x 0.5 ... 4 mm²
Rigid 2x 0.5 ... 2.5 mm²
Tightening Torque0.6 ... 0.8 N·m
Wire Stripping Length8 mm
Recommended Screw Driver0.8 x 4
4.5
Pozidriv 1
Mounting Position1 ... 6
Mounting on DIN RailTH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715
TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
StandardsCAN/CSA C22.2 No.14
IEC/EN 63000
IEC/EN 60255-27
IEC/EN 61000-6-2
IEC/EN 61000-6-3
UL 508
Technical UL/CSA
Maximum Operating Voltage UL/CSAOutput Circuit 300 V AC
Contact Rating UL/CSAB300
Connecting Capacity UL/CSAFlexible 1x 18-14 AWG
Flexible 2x 18-16 AWG
Rigid 1x 20-12 AWG
Rigid 2x 20-14 AWG
Tightening Torque UL/CSA7.08 in·lb
Pilot Duty UL/CSAB300
Flammability According to UL94V-0
Environmental
Ambient Air TemperatureOperation -25 ... +60 °C
Storage -40 ... +85 °C
Maximum Operating Altitude PermissibleWithout Derating 2000 m
Material Compliance
Conflict Minerals Reporting Template (CMRT)9AKK108467A5658
REACH Declaration1SVD981001-4501
RoHS Declaration1SVD981001-4401
SCIP16cf4964-d532-4d33-a427-3af5401bea65 Germany
Simplified SCIP4d9c9cff-cfd4-47ef-ab30-107415f4cc21 Poland
4db92145-9835-4a7c-8f4d-3406f7cf3b95 Norway
5cf081b3-440b-4001-a5d9-92e9516c72bb Finland
817605ad-4c3e-4ddd-b7bf-599bd5ffe4ef Denmark
6d91f2e6-1499-4ed9-8874-117f42936779 Belgium
c6721df0-d1a1-4819-90f8-4d3784e5c3e2 Germany
2a9e9aac-f274-44f0-a1a6-d68fe55621d1 Italy
d8f1f984-068d-4add-b14b-b5db9a5c7acb Germany
07cf0c1a-3acc-45a6-91e2-492b1dc09a97 Czech Republic
3393b968-1836-4797-99ef-bf29213ad8ef Germany
a56091c8-bc42-4d92-82f6-e895d7d4819e Estonia
4c63c5e5-7883-4875-ace6-abcff4e9bf40 Croatia
3a608af4-7c0e-450a-9e50-a19030cfd8e4 Greece
3d9266af-aaf8-49e3-8d76-e4df6431de7c Portugal
c303a13a-5b20-404e-8a89-258d2d536fb5 France
62d501b1-fc12-4716-a147-238958121ee8 France
65cc58e1-f97a-4cfb-8414-51f1ced689fa Poland
3c0caff1-e718-4b3d-bbeb-d11076f00ebb Sweden
c01ed0aa-1f2c-4c8a-9926-5d99eb83e21b Germany
017cf210-c8e6-4fd6-b247-c46aa8f7e03e Sweden
e29c8a14-4a2c-4ea2-992c-bbb3538ec4fc Bulgaria
e4fe664f-4774-4471-a54d-a84edc623de4 Hungary
41687907-7884-472e-8de6-81486b5200aa Netherlands
84fca779-100f-4235-a8c9-f8f2a1665fdc Poland
55eb9fe2-b47a-4e0c-b381-1ab39797a28d Spain
18002afa-8084-460b-a190-63d942f6e79e Hungary
338258a5-7afc-4193-b5d4-b5a6b2a603cf Belgium
Toxic Substances Control Act - TSCA2CMT2023-006536
ABB EcoSolutions
ABB EcoSolutionsYes
Environmental Product Declaration - EPD1SAC200438H0001
Certificates and Declarations
CQC CertificateCQC2009010303326655
cULus CertificatecULus508_20120829-E140448
Declaration of Conformity - CCC2020980303000197
Declaration of Conformity - CE1SVD981014-00
Declaration of Conformity - UKCA1SVD981014-10
DNV GL CertificateDNV_GL_TAA000017D
Container Information
Package Level 1 Unitsbox 1 piece
Package Level 1 Width97 mm
Package Level 1 Depth / Length30 mm
Package Level 1 Height109 mm
Package Level 1 Gross Weight0.157 kg
Package Level 1 EAN4016779851824
External Classifications and Standards
Object Classification CodeB
ETIM 7EC001441 - Phase monitoring relay
ETIM 8EC001441 - Phase monitoring relay
ETIM 9EC001441 - Phase monitoring relay
eClassV11.0 : 27371803
UNSPSC39122332
E-Number (Finland)2712290
E-Number (Norway)4188098
E-Number (Sweden)3860582

Product Datasheet

Electrica Online Product Datasheet Prepared from the current product description, catalog data and structured technical attributes.