View larger
1SVR730784R3300 ABB CM-PSS.41S Three-phase monitoring relay 2c/o, 0,0.1-30s, L1-L2-L3 3x400VAC
1SVR730784R3300
730784
ABB
1 Pcs.
Automation > Phase monitoring relay
Monitoring
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
The 1SVR730784R3300 ABB CM-PSS.41S Three-phase monitoring relay 2c/o, 0,0.1-30s, L1-L2-L3 3x400VAC is a protective device used to monitor three-phase networks for phase loss and ensure proper power quality feeding critical loads. Industrial installations rely on these components to protect motors and power distribution assets from catastrophic phase errors.
Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- EAN: 4016779851824
- Minimum Order Quantity: 1 piece
- Customs Tariff Number: 85364900
- Data Sheet, Technical Information: 2CDC112178D0201
- Instructions and Manuals: 1SVC730730M1000
- CAD Dimensional Drawing: 2CDC001079B0201
- EPLAN Data: 9AAC132605_EPLAN
- Product Net Width: 22.5 mm
- Product Net Height: 85.6 mm
- Product Net Depth / Length: 103.7 mm
- Product Net Weight: 0.132 kg
- Function: Phase failure detection
- Measuring Range: (L-L) 360 ... 440 V AC
- Time Range: Tripping Delay (ON or OFF) 0 second [unit of time]
- Rated Control Supply Voltage (U s ): (L-L) 400 V AC
- Rated Frequency (f): Supply Circuit 50/60 Hz
More info
▲| Ordering | |
|---|---|
| EAN | 4016779851824 |
| Minimum Order Quantity | 1 piece |
| Customs Tariff Number | 85364900 |
| Popular Downloads | |
| Data Sheet, Technical Information | 2CDC112178D0201 |
| Instructions and Manuals | 1SVC730730M1000 |
| 1SVC730730M0000 | |
| CAD Dimensional Drawing | 2CDC001079B0201 |
| EPLAN Data | 9AAC132605_EPLAN |
| Dimensions | |
| Product Net Width | 22.5 mm |
| Product Net Height | 85.6 mm |
| Product Net Depth / Length | 103.7 mm |
| Product Net Weight | 0.132 kg |
| Technical | |
| Function | Phase failure detection |
| Phase sequence monitoring | |
| Over- and undervoltage monitoring | |
| Measuring Range | (L-L) 360 ... 440 V AC |
| Time Range | Tripping Delay (ON or OFF) 0 second [unit of time] |
| Rated Control Supply Voltage (Us) | (L-L) 400 V AC |
| Rated Frequency (f) | Supply Circuit 50/60 Hz |
| Output | 2 C/O Contacts |
| Terminal Type | Screw Terminals |
| Rated Operational Current AC-12 (Ie) | (230 V) 4 A |
| Rated Operational Current AC-15 (Ie) | (230 V) 3 A |
| Rated Operational Current DC-12 (Ie) | (24 V) 4 A |
| Rated Operational Current DC-13 (Ie) | (24 V) 2 A |
| Minimum Switching Capacity | 24 V |
| 10 mA | |
| Rated Impulse Withstand Voltage (Uimp) | Input Circuit 6 kV |
| Output Circuit 4 kV | |
| Rated Insulation Voltage (Ui) | Input Circuit / Output Circuit 600 V |
| Output Circuit 1 / Output Circuit 2 300 V | |
| Degree of Protection | Housing IP50 |
| Terminals IP20 | |
| Overvoltage Category | III |
| Pollution Degree | 3 |
| Short-Circuit Protective Devices | Output Circuit NC - F Type Fuses 6 A |
| Output Circuit NO - F Type Fuses 10 A | |
| Electrical Durability | AC-12 100000 cycle |
| Mechanical Durability | Nr. Operations 30000000 cycle |
| Connecting Capacity | Flexible with Ferrule 1x 0.5 ... 2.5 mm² |
| Flexible with Ferrule 2x 0.5 ... 1.5 mm² | |
| Flexible with Insulated Ferrule 1x 0.5 ... 2.5 mm² | |
| Flexible with Insulated Ferrule 2x 0.5 ... 1.5 mm² | |
| Flexible 1x 0.5 ... 2.5 mm² | |
| Flexible 2x 0.5 ... 1.5 mm² | |
| Rigid 1x 0.5 ... 4 mm² | |
| Rigid 2x 0.5 ... 2.5 mm² | |
| Tightening Torque | 0.6 ... 0.8 N·m |
| Wire Stripping Length | 8 mm |
| Recommended Screw Driver | 0.8 x 4 |
| 4.5 | |
| Pozidriv 1 | |
| Mounting Position | 1 ... 6 |
| Mounting on DIN Rail | TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715 |
| TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715 | |
| Standards | CAN/CSA C22.2 No.14 |
| IEC/EN 63000 | |
| IEC/EN 60255-27 | |
| IEC/EN 61000-6-2 | |
| IEC/EN 61000-6-3 | |
| UL 508 | |
| Technical UL/CSA | |
| Maximum Operating Voltage UL/CSA | Output Circuit 300 V AC |
| Contact Rating UL/CSA | B300 |
| Connecting Capacity UL/CSA | Flexible 1x 18-14 AWG |
| Flexible 2x 18-16 AWG | |
| Rigid 1x 20-12 AWG | |
| Rigid 2x 20-14 AWG | |
| Tightening Torque UL/CSA | 7.08 in·lb |
| Pilot Duty UL/CSA | B300 |
| Flammability According to UL94 | V-0 |
| Environmental | |
| Ambient Air Temperature | Operation -25 ... +60 °C |
| Storage -40 ... +85 °C | |
| Maximum Operating Altitude Permissible | Without Derating 2000 m |
| Material Compliance | |
| Conflict Minerals Reporting Template (CMRT) | 9AKK108467A5658 |
| REACH Declaration | 1SVD981001-4501 |
| RoHS Declaration | 1SVD981001-4401 |
| SCIP | 16cf4964-d532-4d33-a427-3af5401bea65 Germany |
| Simplified SCIP | 4d9c9cff-cfd4-47ef-ab30-107415f4cc21 Poland |
| 4db92145-9835-4a7c-8f4d-3406f7cf3b95 Norway | |
| 5cf081b3-440b-4001-a5d9-92e9516c72bb Finland | |
| 817605ad-4c3e-4ddd-b7bf-599bd5ffe4ef Denmark | |
| 6d91f2e6-1499-4ed9-8874-117f42936779 Belgium | |
| c6721df0-d1a1-4819-90f8-4d3784e5c3e2 Germany | |
| 2a9e9aac-f274-44f0-a1a6-d68fe55621d1 Italy | |
| d8f1f984-068d-4add-b14b-b5db9a5c7acb Germany | |
| 07cf0c1a-3acc-45a6-91e2-492b1dc09a97 Czech Republic | |
| 3393b968-1836-4797-99ef-bf29213ad8ef Germany | |
| a56091c8-bc42-4d92-82f6-e895d7d4819e Estonia | |
| 4c63c5e5-7883-4875-ace6-abcff4e9bf40 Croatia | |
| 3a608af4-7c0e-450a-9e50-a19030cfd8e4 Greece | |
| 3d9266af-aaf8-49e3-8d76-e4df6431de7c Portugal | |
| c303a13a-5b20-404e-8a89-258d2d536fb5 France | |
| 62d501b1-fc12-4716-a147-238958121ee8 France | |
| 65cc58e1-f97a-4cfb-8414-51f1ced689fa Poland | |
| 3c0caff1-e718-4b3d-bbeb-d11076f00ebb Sweden | |
| c01ed0aa-1f2c-4c8a-9926-5d99eb83e21b Germany | |
| 017cf210-c8e6-4fd6-b247-c46aa8f7e03e Sweden | |
| e29c8a14-4a2c-4ea2-992c-bbb3538ec4fc Bulgaria | |
| e4fe664f-4774-4471-a54d-a84edc623de4 Hungary | |
| 41687907-7884-472e-8de6-81486b5200aa Netherlands | |
| 84fca779-100f-4235-a8c9-f8f2a1665fdc Poland | |
| 55eb9fe2-b47a-4e0c-b381-1ab39797a28d Spain | |
| 18002afa-8084-460b-a190-63d942f6e79e Hungary | |
| 338258a5-7afc-4193-b5d4-b5a6b2a603cf Belgium | |
| Toxic Substances Control Act - TSCA | 2CMT2023-006536 |
| ABB EcoSolutions | |
| ABB EcoSolutions | Yes |
| Environmental Product Declaration - EPD | 1SAC200438H0001 |
| Certificates and Declarations | |
| CQC Certificate | CQC2009010303326655 |
| cULus Certificate | cULus508_20120829-E140448 |
| Declaration of Conformity - CCC | 2020980303000197 |
| Declaration of Conformity - CE | 1SVD981014-00 |
| Declaration of Conformity - UKCA | 1SVD981014-10 |
| DNV GL Certificate | DNV_GL_TAA000017D |
| Container Information | |
| Package Level 1 Units | box 1 piece |
| Package Level 1 Width | 97 mm |
| Package Level 1 Depth / Length | 30 mm |
| Package Level 1 Height | 109 mm |
| Package Level 1 Gross Weight | 0.157 kg |
| Package Level 1 EAN | 4016779851824 |
| External Classifications and Standards | |
| Object Classification Code | B |
| ETIM 7 | EC001441 - Phase monitoring relay |
| ETIM 8 | EC001441 - Phase monitoring relay |
| ETIM 9 | EC001441 - Phase monitoring relay |
| eClass | V11.0 : 27371803 |
| UNSPSC | 39122332 |
| E-Number (Finland) | 2712290 |
| E-Number (Norway) | 4188098 |
| E-Number (Sweden) | 3860582 |