ABB 1SVR740784R3300 1SVR740784R3300 ABB CM-PSS.41P Three-phase monitoring relay 2c/o, 0,0.1-30s, L1-L2-L3 3x400VAC View larger
Images are for illustrative purposes only. Please refer to data sheet for details

1SVR740784R3300 ABB CM-PSS.41P Three-phase monitoring relay 2c/o, 0,0.1-30s, L1-L2-L3 3x400VAC

1SVR740784R3300

740784

ABB

1 Pcs.

CM-PSS.41P Three-phase monitoring relay 2c/o, 0,0.1-30s, L1-L2-L3=3x400VAC CM-PSS.41P RELe CTRL THREE-PHASE 2 C/C RES

Automation > Phase monitoring relay
Monitoring

Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.

Request a Quote

Pricing and availability are confirmed for each enquiry. Add your required quantity to begin.

No account, online checkout or payment is required.

More info

Ordering
EAN4016779852005
Minimum Order Quantity1 piece
Customs Tariff Number85364900
Popular Downloads
Data Sheet, Technical Information2CDC112178D0201
Instructions and Manuals1SVC730730M1000
1SVC730730M0000
CAD Dimensional Drawing2CDC001079B0201
EPLAN Data9AAC132605_EPLAN
Dimensions
Product Net Width22.5 mm
Product Net Height85.6 mm
Product Net Depth / Length103.7 mm
Product Net Weight0.123 kg
Technical
FunctionPhase failure detection
Phase sequence monitoring
Over- and undervoltage monitoring
Measuring Range(L-L) 360 ... 440 V AC
Time RangeTripping Delay (ON or OFF) 0 second [unit of time]
Rated Control Supply Voltage (Us)(L-L) 400 V AC
Rated Frequency (f)Supply Circuit 50/60 Hz
Output2 c/o (SPDT) contacts
Terminal TypeScrewless Terminals
Rated Operational Current AC-12 (Ie)(230 V) 4 A
Rated Operational Current AC-15 (Ie)(230 V) 3 A
Rated Operational Current DC-12 (Ie)(24 V) 4 A
Rated Operational Current DC-13 (Ie)(24 V) 2 A
Minimum Switching Capacity24 V
10 mA
Rated Impulse Withstand Voltage (Uimp)Input Circuit 6 kV
Output Circuit 4 kV
Rated Insulation Voltage (Ui)Input Circuit / Output Circuit 600 V
Output Circuit 1 / Output Circuit 2 300 V
Degree of ProtectionHousing IP50
Terminals IP20
Overvoltage CategoryIII
Pollution Degree3
Short-Circuit Protective DevicesOutput Circuit NC - F Type Fuses 6 A
Output Circuit NO - F Type Fuses 10 A
Electrical DurabilityAC-12 100000 cycle
Mechanical DurabilityNr. Operations 30000000 cycle
Connecting CapacityFlexible with Ferrule 2x 0.5 ... 1.5 mm²
Flexible with Insulated Ferrule 2x 0.5 ... 1.5 mm²
Flexible 2x 0.5 ... 1.5 mm²
Rigid 2x 0.5 ... 1.5 mm²
Wire Stripping Length8 mm
Mounting Position1 ... 6
Mounting on DIN RailTH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715
TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
StandardsCAN/CSA C22.2 No.14
IEC/EN 63000
IEC/EN 60255-27
IEC/EN 61000-6-2
IEC/EN 61000-6-3
UL 508
Technical UL/CSA
Maximum Operating Voltage UL/CSAOutput Circuit 300 V AC
Contact Rating UL/CSAB300
Connecting Capacity UL/CSAFlexible 2x 18-16 AWG
Rigid 2x 20-16 AWG
Pilot Duty UL/CSAB300
Flammability According to UL94V-0
Environmental
Ambient Air TemperatureOperation -25 ... +60 °C
Storage -40 ... +85 °C
Maximum Operating Altitude PermissibleWithout Derating 2000 m
Material Compliance
Conflict Minerals Reporting Template (CMRT)9AKK108467A5658
REACH Declaration1SVD981001-4501
RoHS Declaration1SVD981001-4401
SCIP2556ffbb-efd6-45c4-bb68-f86613010803 Germany
Simplified SCIP7056ad77-139d-4eeb-ad52-19a31d3d3ff7 Portugal
01db01b8-0119-4d47-9b7b-f450b599abd6 Bulgaria
d6813bdb-1a3b-420d-be20-177a0d1fa938 Greece
39af5a04-c315-43ab-9b03-2dea1f351abe Norway
4b193b01-98dd-4aa4-a6bd-8a3c90225407 Poland
4e24294a-0649-4abd-8394-7aed1b097d1b Finland
e0d2a806-dfff-4d68-a211-3cbbbb9ce733 Belgium
8efb128f-3743-4da2-a7bd-f1c2cad0e350 Denmark
fa45542f-6ea8-4e08-ae6f-3e6ae7d9244f Germany
ce75bc46-63a0-43a3-8295-54404db0eb4e Italy
df675d46-ca18-4743-b627-09e2d8d55313 Germany
8ef4ab4d-c522-488c-a1ab-6cf1ed52c956 Belgium
e7f5e089-eeba-4f5e-9da9-6e8122d20bac France
6aa77b01-ba67-4bee-8eb6-f0199068c092 France
e7359e03-d580-41ab-96cd-920c9325dd4d Poland
c3a37b83-cad4-4c89-ab50-02110f075fea Germany
e75bd882-98db-4569-a9bd-a5a6ed493c5b Sweden
f72a0770-5f1c-4619-a7ed-b58215b7e222 Sweden
3aad1979-4dc3-4be3-9463-2594cd026ebf Hungary
679dd6a5-dada-4893-8e0c-42285a04a9ba Spain
b5efb95b-bf44-448b-a930-238216a766df Czech Republic
dc87180e-15e3-4673-b3a2-a50f23db5541 Germany
4e474543-f391-46be-a6b2-e9b5de4a36bb Poland
4fd56584-eb84-4a38-83bf-28a10fa54f79 Estonia
7996476d-3a3c-4b10-aff1-fc08ad48b67e Croatia
0159e896-d138-4d84-b396-8b3698f3207f Netherlands
d81139b8-4614-4899-ba8a-a45d0f3f2aa3 Hungary
Toxic Substances Control Act - TSCA2CMT2023-006536
ABB EcoSolutions
Environmental Product Declaration - EPD1SAC200438H0001
Certificates and Declarations
CQC CertificateCQC2009010303326655
cULus CertificatecULus508_20120829-E140448
Declaration of Conformity - CCC2020980303000197
Declaration of Conformity - CE1SVD981014-00
Declaration of Conformity - UKCA1SVD981014-10
DNV GL CertificateDNV_GL_TAA000017D
Container Information
Package Level 1 Unitsbox 1 piece
Package Level 1 Width97 mm
Package Level 1 Depth / Length30 mm
Package Level 1 Height109 mm
Package Level 1 Gross Weight0.148 kg
Package Level 1 EAN4016779852005
External Classifications and Standards
Object Classification CodeB
ETIM 7EC001441 - Phase monitoring relay
ETIM 8EC001441 - Phase monitoring relay
ETIM 9EC001441 - Phase monitoring relay
eClassV11.0 : 27371803
UNSPSC39122332
E-Number (Finland)2712289
E-Number (Norway)4188099
E-Number (Sweden)3860601

Product Datasheet

Electrica Online Product Datasheet Prepared from the current product description, catalog data and structured technical attributes.