ABB 1SVR740784R2300 1SVR740784R2300 ABB CM-PSS.31P Three-phase monitoring relay 2c/o, 0,0.1-30s, L1-L2-L3 3x380VAC View larger
Images are for illustrative purposes only. Please refer to data sheet for details

1SVR740784R2300 ABB CM-PSS.31P Three-phase monitoring relay 2c/o, 0,0.1-30s, L1-L2-L3 3x380VAC

1SVR740784R2300

740784

ABB

1 Pcs.

CM-PSS.31P Three-phase monitoring relay 2c/o, 0,0.1-30s, L1-L2-L3=3x380VAC CM-PSS.31P RELe CTRL THREE-PHASE 2 C/C RES

Automation > Phase monitoring relay
Monitoring

Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.

Request a Quote

Pricing and availability are confirmed for each enquiry. Add your required quantity to begin.

No account, online checkout or payment is required.

More info

Ordering
EAN4016779851992
Minimum Order Quantity1 piece
Customs Tariff Number85364900
Popular Downloads
Data Sheet, Technical Information2CDC112178D0201
Instructions and Manuals1SVC730730M1000
1SVC730730M0000
CAD Dimensional Drawing2CDC001079B0201
EPLAN Data9AAC132605_EPLAN
Dimensions
Product Net Width22.5 mm
Product Net Height85.6 mm
Product Net Depth / Length103.7 mm
Product Net Weight0.123 kg
Technical
FunctionPhase failure detection
Phase sequence monitoring
Over- and undervoltage monitoring
Measuring Range(L-L) 342 ... 418 V AC
Time RangeTripping Delay (ON or OFF) 0 second [unit of time]
Rated Control Supply Voltage (Us)(L-L) 380 V AC
Rated Frequency (f)Supply Circuit 50/60 Hz
Output2 c/o (SPDT) contacts
Terminal TypeScrewless Terminals
Rated Operational Current AC-12 (Ie)(230 V) 4 A
Rated Operational Current AC-15 (Ie)(230 V) 3 A
Rated Operational Current DC-12 (Ie)(24 V) 4 A
Rated Operational Current DC-13 (Ie)(24 V) 2 A
Minimum Switching Capacity24 V
10 mA
Rated Impulse Withstand Voltage (Uimp)Input Circuit 6 kV
Output Circuit 4 kV
Rated Insulation Voltage (Ui)Input Circuit / Output Circuit 600 V
Output Circuit 1 / Output Circuit 2 300 V
Degree of ProtectionHousing IP50
Terminals IP20
Overvoltage CategoryIII
Pollution Degree3
Short-Circuit Protective DevicesOutput Circuit NC - F Type Fuses 6 A
Output Circuit NO - F Type Fuses 10 A
Electrical DurabilityAC-12 100000 cycle
Mechanical DurabilityNr. Operations 30000000 cycle
Connecting CapacityFlexible with Ferrule 2x 0.5 ... 1.5 mm²
Flexible with Insulated Ferrule 2x 0.5 ... 1.5 mm²
Flexible 2x 0.5 ... 1.5 mm²
Rigid 2x 0.5 ... 1.5 mm²
Wire Stripping Length8 mm
Mounting Position1 ... 6
Mounting on DIN RailTH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715
TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
StandardsCAN/CSA C22.2 No.14
IEC/EN 63000
IEC/EN 60255-27
IEC/EN 61000-6-2
IEC/EN 61000-6-3
UL 508
Technical UL/CSA
Maximum Operating Voltage UL/CSAOutput Circuit 300 V AC
Contact Rating UL/CSAB300
Connecting Capacity UL/CSAFlexible 2x 18-16 AWG
Rigid 2x 20-16 AWG
Pilot Duty UL/CSAB300
Flammability According to UL94V-0
Environmental
Ambient Air TemperatureOperation -25 ... +60 °C
Storage -40 ... +85 °C
Maximum Operating Altitude PermissibleWithout Derating 2000 m
Material Compliance
Conflict Minerals Reporting Template (CMRT)9AKK108467A5658
REACH Declaration1SVD981001-4501
RoHS Declaration1SVD981001-4401
SCIP417b58f1-42cc-4ac0-a0fe-47ef4807546f Germany
Simplified SCIPc485f6ef-d728-4998-a4e6-a3e6a9ac63dc Belgium
a5d2d6fe-10de-4619-b95d-fe4b5321d0ab Hungary
9fc6983e-c651-4925-a1d7-e450b153a22c Spain
6e6b045c-b231-4bc0-be5b-0549fca1783a Bulgaria
1b6a28f3-2b9b-4b44-bddb-c25efdd68252 Germany
abd6b23d-0e4a-491a-ad4b-affafe979aef Sweden
c926a01f-cc09-4ac9-b074-6388f48796f3 Poland
c7581e5f-b005-4b71-ab5d-9b6e29c5ddbe Sweden
4cf58197-f8a7-451f-bf07-d8081615be54 France
a265079a-b50e-48c5-90ac-8dc16175aca2 France
d32865cf-41a9-47f2-8d3b-f6b3c0c9da4e Greece
c32368d9-779f-4148-b829-f9562f26b0a8 Hungary
ff5fe14f-a240-408a-be8b-4a49aba938d9 Portugal
651b5b0d-a1ad-4125-86b6-a788fc887c40 Germany
c993e6ca-aa64-456a-98fd-672db4e5b588 Germany
13291f8f-5c5e-44ea-b9a4-d3f85914734c Czech Republic
2e0b5eb0-744d-439f-8294-bc110e893a1d Croatia
00af81e0-ae03-444f-8d32-cc344b138297 Estonia
8ea3dcfc-1bdc-474c-8079-56fd07dfc39d Poland
434933b2-cb0c-4428-9ba5-a1b199ba5982 Netherlands
08478363-483c-4e04-9114-554e479befc0 Denmark
89133ab9-26a6-4e83-b5f0-df967d4a89b3 Poland
4359fc03-d467-4ae9-b320-833196d0c8cb Belgium
c3913901-592f-42aa-b327-55e622134927 Germany
a6f55f71-e2d7-4464-a107-e849dcad12c7 Finland
4c15d769-bd88-416a-8529-a601bebd6394 Norway
f6fa44a9-d4d8-49f6-b396-34be8a4a16bc Italy
Toxic Substances Control Act - TSCA2CMT2023-006536
ABB EcoSolutions
Environmental Product Declaration - EPD1SAC200438H0001
Certificates and Declarations
CQC CertificateCQC2009010303326655
cULus CertificatecULus508_20120829-E140448
Declaration of Conformity - CCC2020980303000197
Declaration of Conformity - CE1SVD981014-00
Declaration of Conformity - UKCA1SVD981014-10
DNV GL CertificateDNV_GL_TAA000017D
Container Information
Package Level 1 Unitsbox 1 piece
Package Level 1 Width97 mm
Package Level 1 Depth / Length30 mm
Package Level 1 Height109 mm
Package Level 1 Gross Weight0.148 kg
Package Level 1 EAN4016779851992
External Classifications and Standards
Object Classification CodeB
ETIM 7EC001441 - Phase monitoring relay
ETIM 8EC001441 - Phase monitoring relay
ETIM 9EC001441 - Phase monitoring relay
eClassV11.0 : 27371803
UNSPSC39122332
E-Number (Finland)2712287
E-Number (Norway)4188097
E-Number (Sweden)3860600

Product Datasheet

Electrica Online Product Datasheet Prepared from the current product description, catalog data and structured technical attributes.