View larger
1SVR550824R9100
550824
ABB
1 Pcs.
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
| Ordering | |
|---|---|
| EAN | 4013614348044 |
| Minimum Order Quantity | 1 piece |
| Customs Tariff Number | 85364900 |
| Popular Downloads | |
| Data Sheet, Technical Information | 2CDC112231D0201 |
| Instructions and Manuals | 1SVC550510M0002 |
| CAD Dimensional Drawing | 2CDC001079B0201 |
| Dimensions | |
| Product Net Width | 22.5 mm |
| Product Net Height | 78 mm |
| Product Net Depth / Length | 78.5 mm |
| Product Net Weight | 0.068 kg |
| Technical | |
| Function | Phase failure detection |
| Phase sequence monitoring | |
| Sub-Function | Phase loss |
| Sub-Function 2 | Phase sequence |
| Measuring Range | (L-L) 208 ... 440 V AC |
| Time Range | Tripping Delay (ON or OFF) 500 ms |
| Rated Control Supply Voltage (Us) | (L-L) 208 ... 440 V AC |
| Rated Frequency (f) | Supply Circuit 50/60 Hz |
| Output | 1 C/O (SPDT) Contact |
| Terminal Type | Screw Terminals |
| Rated Operational Current AC-12 (Ie) | (230 V) 4 A |
| Rated Operational Current AC-15 (Ie) | (230 V) 3 A |
| Rated Operational Current DC-12 (Ie) | (24 V) 4 A |
| Rated Operational Current DC-13 (Ie) | (24 V) 2 A |
| Rated Impulse Withstand Voltage (Uimp) | Input Circuit 6 kV |
| Rated Insulation Voltage (Ui) | Input Circuit / Output Circuit 600 V |
| Degree of Protection | Housing IP50 |
| Terminals IP20 | |
| Overvoltage Category | III |
| Pollution Degree | 3 |
| Short-Circuit Protective Devices | Output Circuit NC - F Type Fuses 6 A |
| Output Circuit NO - F Type Fuses 10 A | |
| Connecting Capacity | Flexible with Ferrule 2x 0.75 ... 1.5 mm² |
| Flexible 2x 1 ... 1.5 mm² | |
| Rigid 2x 0.75 ... 1.5 mm² | |
| Tightening Torque | 0.6 ... 0.8 N·m |
| Wire Stripping Length | 10 mm |
| Mounting Position | 1 ... 6 |
| Mounting on DIN Rail | TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715 |
| TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715 | |
| Standards | IEC/EN 63000 |
| IEC/EN 60255-27 | |
| IEC/EN 61000-6-2 | |
| IEC/EN 61000-6-3 | |
| UL 508 | |
| Technical UL/CSA | |
| Maximum Operating Voltage UL/CSA | Output Circuit 250 V AC |
| Contact Rating UL/CSA | B300 |
| Connecting Capacity UL/CSA | Flexible with Ferrule 2x 18-16 AWG |
| Flexible 2x 18-16 AWG | |
| Rigid 2x 18-16 AWG | |
| Tightening Torque UL/CSA | 7.08 in·lb |
| Pilot Duty UL/CSA | B300 |
| Environmental | |
| Ambient Air Temperature | Operation -20 ... +60 °C |
| Storage -40 ... +85 °C | |
| Maximum Operating Altitude Permissible | Without Derating 2000 m |
| Material Compliance | |
| Conflict Minerals Reporting Template (CMRT) | 9AKK108467A5658 |
| REACH Declaration | 1SVD981001-4501 |
| RoHS Declaration | 1SVD981001-4401 |
| SCIP | ba3b764b-e0a9-4840-a948-5a6c36a5fa1b Germany |
| Simplified SCIP | 6e1492a5-bf3a-4236-980f-4fdb2518df43 Belgium |
| 88c45007-a3f0-4e77-bc23-9e40f3d9043e Hungary | |
| f21e45c4-a023-4ee8-aae4-0f491a8c5519 Spain | |
| e5a4b992-f0c8-4838-8f61-4dbf0f342418 Sweden | |
| ba13dafe-4a99-44cc-9148-26abb6ffd876 Germany | |
| 51ac8159-359f-450f-bbf7-96cf8a4fa30f Sweden | |
| 0b82d33c-39b2-41d7-96fd-10051877324e Poland | |
| cc93c32a-4aad-4bdf-a6d6-3a675d84299f France | |
| 782bfe1a-df6a-43e2-8a73-660d4d837575 France | |
| a87e620f-c7c9-4a59-8049-3eec1ee43552 Greece | |
| 8bae1d9b-ff52-4a1e-a3b4-afa6e1df8332 Portugal | |
| f0ce95b9-0a69-4ee0-b481-1a18e18e9781 Bulgaria | |
| 506af2b5-16ad-412c-98ee-7f829d493c4a Poland | |
| 16bf19f4-1ebe-4d27-978f-5a0f7fa72a57 Netherlands | |
| bb6c8254-e7d2-4849-be74-ec9fb1b8e0cc Hungary | |
| 67aebc77-990e-4d36-ba92-efd2b28ffb5a Germany | |
| 10d2bae3-fb24-4173-b0a0-f44dbb8536b0 Croatia | |
| 8ee9a5e4-08dd-402b-8f1a-373a82a1b87a Czech Republic | |
| 12697206-2b6c-48c0-a638-387243fa6cd9 Germany | |
| ebdf3c09-d4a5-4be0-8bca-fb6b978b2af4 Estonia | |
| b289a72f-6a23-4abf-a9a3-fb18d4efae1a Germany | |
| daa202bf-633f-4bb1-b8f1-3577676c7bc5 Belgium | |
| 5d1bc9e0-db85-44f2-8757-0be56302df0c Finland | |
| ceb7ac61-80ab-4af5-a7cf-51868073aa75 Poland | |
| cd7df2da-e083-4660-902d-c4eca9572c47 Norway | |
| ce9836f8-ea91-4c08-be12-fec72e6b796a Denmark | |
| 851de4d2-fe53-451c-b4bd-bd474f9cd6ae Italy | |
| Toxic Substances Control Act - TSCA | 2CMT2023-006536 |
| Certificates and Declarations | |
| CCC Certificate | CCC_2013010303605960 |
| CQC Certificate | CQC2013010303605960 |
| Declaration of Conformity - CCC | 2020980303000202 |
| Declaration of Conformity - CE | 1SVD981026-00 |
| Declaration of Conformity - UKCA | 1SVD981026-10 |
| UL Certificate | UL508_E140448 |
| Container Information | |
| Package Level 1 Units | box 1 piece |
| Package Level 1 Width | 23 mm |
| Package Level 1 Depth / Length | 82 mm |
| Package Level 1 Height | 82 mm |
| Package Level 1 Gross Weight | 0.08 kg |
| Package Level 1 EAN | 4013614348044 |
| Package Level 2 EAN | 4013614580758 |
| External Classifications and Standards | |
| Object Classification Code | B |
| ETIM 7 | EC001441 - Phase monitoring relay |
| ETIM 8 | EC001441 - Phase monitoring relay |
| ETIM 9 | EC001441 - Phase monitoring relay |
| eClass | V11.0 : 27371803 |
| UNSPSC | 39122332 |
| E-Number (Finland) | 2712846 |
| E-Number (Norway) | 4187172 |
| E-Number (Sweden) | 3860173 |