ABB 1SVR730774R3300 1SVR730774R3300 ABB CM-PAS.41S Three-phase monitoring relay 2c/o, 0,0.1-30s, L1-L2-L3 3x300-500VAC View larger
Images are for illustrative purposes only. Please refer to data sheet for details

1SVR730774R3300 ABB CM-PAS.41S Three-phase monitoring relay 2c/o, 0,0.1-30s, L1-L2-L3 3x300-500VAC

1SVR730774R3300

730774

ABB

1 Pcs.

CM-PAS.41S Three-phase monitoring relay 2c/o, 0,0.1-30s, L1-L2-L3=3x300-500VAC CM-PAS.41S RELe CTRL THREE-PHASE 2 C/C TOR

Automation > Phase monitoring relay
Monitoring

Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.

Request a Quote

Pricing and availability are confirmed for each enquiry. Add your required quantity to begin.

No account, online checkout or payment is required.

More info

Ordering
EAN4016779851800
Minimum Order Quantity1 piece
Customs Tariff Number85364900
Popular Downloads
Data Sheet, Technical Information2CDC112180D0201
Instructions and Manuals1SVC730730M1000
1SVC730730M0000
CAD Dimensional Drawing2CDC001079B0201
EPLAN Data9AAC132606_EPLAN
Dimensions
Product Net Width22.5 mm
Product Net Height85.6 mm
Product Net Depth / Length103.7 mm
Product Net Weight0.132 kg
Technical
FunctionPhase failure detection
Phase sequence monitoring
Phase unbalance detection
Measuring Range(L-L) 300 ... 500 V AC
Time RangeTripping Delay (ON) 0 second [unit of time]
Rated Control Supply Voltage (Us)(L-L) 300 ... 500 V AC
Rated Frequency (f)Supply Circuit 50/60 Hz
Output2 c/o (SPDT) contacts
Terminal TypeScrew Terminals
Rated Operational Current AC-12 (Ie)(230 V) 4 A
Rated Operational Current AC-15 (Ie)(230 V) 3 A
Rated Operational Current DC-12 (Ie)(24 V) 4 A
Rated Operational Current DC-13 (Ie)(24 V) 2 A
Minimum Switching Capacity24 V
10 mA
Rated Impulse Withstand Voltage (Uimp)Input Circuit 6 kV
Output Circuit 4 kV
Rated Insulation Voltage (Ui)Input Circuit / Output Circuit 600 V
Output Circuit 1 / Output Circuit 2 300 V
Degree of ProtectionHousing IP50
Terminals IP20
Overvoltage CategoryIII
Pollution Degree3
Short-Circuit Protective DevicesOutput Circuit NC - F Type Fuses 6 A
Output Circuit NO - F Type Fuses 10 A
Electrical DurabilityAC-12 100000 cycle
Mechanical DurabilityNr. Operations 30000000 cycle
Connecting CapacityFlexible with Ferrule 1x 0.5 ... 2.5 mm²
Flexible with Ferrule 2x 0.5 ... 1.5 mm²
Flexible with Insulated Ferrule 1x 0.5 ... 2.5 mm²
Flexible with Insulated Ferrule 2x 0.5 ... 1.5 mm²
Flexible 1x 0.5 ... 2.5 mm²
Flexible 2x 0.5 ... 1.5 mm²
Rigid 1x 0.5 ... 4 mm²
Rigid 2x 0.5 ... 2.5 mm²
Tightening Torque0.6 ... 0.8 N·m
Wire Stripping Length8 mm
Recommended Screw Driver0.8 x 4
4.5
Pozidriv 1
Mounting Position1 ... 6
Mounting on DIN RailTH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715
TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
StandardsCAN/CSA C22.2 No.14
IEC/EN 63000
IEC/EN 60255-27
IEC/EN 61000-6-2
IEC/EN 61000-6-3
UL 508
Technical UL/CSA
Maximum Operating Voltage UL/CSAOutput Circuit 300 V AC
Contact Rating UL/CSAB300
Connecting Capacity UL/CSAFlexible 1x 18-14 AWG
Flexible 2x 18-16 AWG
Rigid 1x 20-12 AWG
Rigid 2x 20-14 AWG
Tightening Torque UL/CSA7.08 in·lb
Pilot Duty UL/CSAB300
Flammability According to UL94V-0
Environmental
Ambient Air TemperatureOperation -25 ... +60 °C
Storage -40 ... +85 °C
Maximum Operating Altitude PermissibleWithout Derating 2000 m
Material Compliance
Conflict Minerals Reporting Template (CMRT)9AKK108467A5658
REACH Declaration1SVD981001-4501
RoHS Declaration1SVD981001-4401
SCIP448bb180-fee1-4ae5-9a53-2026066e7bc4 Germany
Simplified SCIP66cca6ee-c44a-4b7c-bfd2-187e30345218 Belgium
e9456fb1-48ef-4f73-b675-b2870c576dea Germany
78a0b3ab-16f2-46c7-b3f0-ebbf15bc5b89 Norway
f03a6182-65a0-4b4c-a1a3-b2721547b4b3 Finland
c8bf5efe-ca54-4cd0-843c-3a3cf9b2dac7 Denmark
536f1157-45b1-4dfb-a85f-4dbbaeadb690 Poland
6dda6c6f-9aa4-4a73-833e-8c251188c9c1 Italy
cde37705-acf3-4ab7-be4b-a4e195bb7ca7 Estonia
16e7bfbc-9f08-4427-8f42-cebc8aac3fbe Czech Republic
3f62a6ab-cac9-4d10-b7bc-7fb3fde78691 Germany
a03845c8-5b58-4f76-b11c-f28960b5b595 Germany
4939afed-8387-4a24-9daa-61c622903109 Croatia
330faf47-a263-49a4-8134-980aaf2a55e3 Belgium
282ef598-aeef-43fd-8079-8ad4af4ec90f Hungary
1c4d121c-07a1-4916-9703-591f13c35bfc Spain
3a538c0b-1192-4a4b-aa39-a1258de14b74 Greece
f14dfe65-11e2-4353-bd8d-9eff8bd1d549 Portugal
8a21c0f5-57a0-47ed-bc49-74558dcbf206 France
1177fd82-1ccf-4306-acba-c6d78249bb5f France
be5ffde9-e5d1-43e7-b15b-930582ba803b Bulgaria
1ceb74f5-9e3d-4be6-beb7-b594b161bc7d Sweden
6f116b51-003c-4a00-9530-ecd3d67631fe Germany
5ab3840f-e473-4d60-bf7f-ab1a5c60f800 Sweden
83ef4a3e-a3a5-4855-b700-5a65586cd841 Poland
2fbf610a-c9c6-4c79-8771-72338c306fd1 Hungary
e10ce8a4-3d5c-41e3-96be-045dc486d245 Poland
b21eb7dc-a49c-4e5b-9c54-f4db8bb4a4f9 Netherlands
Toxic Substances Control Act - TSCA2CMT2023-006536
ABB EcoSolutions
ABB EcoSolutionsYes
Environmental Product Declaration - EPD1SAC200438H0001
Certificates and Declarations
CQC CertificateCQC2009010303326655
cULus CertificatecULus508_20120829-E140448
Declaration of Conformity - CCC2020980303000197
Declaration of Conformity - CE1SVD981014-00
Declaration of Conformity - UKCA1SVD981014-10
DNV GL CertificateDNV_GL_TAA000017D
Container Information
Package Level 1 Unitsbox 1 piece
Package Level 1 Width97 mm
Package Level 1 Depth / Length30 mm
Package Level 1 Height109 mm
Package Level 1 Gross Weight0.157 kg
Package Level 1 EAN4016779851800
External Classifications and Standards
Object Classification CodeB
ETIM 7EC001441 - Phase monitoring relay
ETIM 8EC001441 - Phase monitoring relay
ETIM 9EC001441 - Phase monitoring relay
eClassV11.0 : 27371803
UNSPSC39122332
E-Number (Finland)2712284
E-Number (Norway)4188161
E-Number (Sweden)3860580

Product Datasheet

Electrica Online Product Datasheet Prepared from the current product description, catalog data and structured technical attributes.