ABB 1SVR730774R1300 1SVR730774R1300 ABB CM-PAS.31S Three-phase monitoring relay 2c/o, 0,0.1-30s, L1-L2-L3 3x160-300VAC View larger
Images are for illustrative purposes only. Please refer to data sheet for details

1SVR730774R1300 ABB CM-PAS.31S Three-phase monitoring relay 2c/o, 0,0.1-30s, L1-L2-L3 3x160-300VAC

1SVR730774R1300

730774

ABB

1 Pcs.

CM-PAS.31S Three-phase monitoring relay 2c/o, 0,0.1-30s, L1-L2-L3=3x160-300VAC CM-PAS.31S RELe CTRL THREE-PHASE 2 C/C TOR

Automation > Phase monitoring relay
Monitoring

Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.

Request a Quote

Pricing and availability are confirmed for each enquiry. Add your required quantity to begin.

No account, online checkout or payment is required.

More info

Ordering
EAN4016779851794
Minimum Order Quantity1 piece
Customs Tariff Number85364900
Popular Downloads
Data Sheet, Technical Information2CDC112180D0201
Instructions and Manuals1SVC730730M1000
1SVC730730M0000
CAD Dimensional Drawing2CDC001079B0201
EPLAN Data9AAC132606_EPLAN
Dimensions
Product Net Width22.5 mm
Product Net Height85.6 mm
Product Net Depth / Length103.7 mm
Product Net Weight0.133 kg
Technical
FunctionPhase failure detection
Phase sequence monitoring
Phase unbalance detection
Measuring Range(L-L) 160 ... 300 V AC
Time RangeTripping Delay (ON) 0 second [unit of time]
Rated Control Supply Voltage (Us)(L-L) 160 ... 300 V AC
Rated Frequency (f)Supply Circuit 50/60 Hz
Output2 c/o (SPDT) contacts
Terminal TypeScrew Terminals
Rated Operational Current AC-12 (Ie)(230 V) 4 A
Rated Operational Current AC-15 (Ie)(230 V) 3 A
Rated Operational Current DC-12 (Ie)(24 V) 4 A
Rated Operational Current DC-13 (Ie)(24 V) 2 A
Minimum Switching Capacity24 V
10 mA
Rated Impulse Withstand Voltage (Uimp)Input Circuit 6 kV
Output Circuit 4 kV
Rated Insulation Voltage (Ui)Input Circuit / Output Circuit 600 V
Output Circuit 1 / Output Circuit 2 300 V
Degree of ProtectionHousing IP50
Terminals IP20
Overvoltage CategoryIII
Pollution Degree3
Short-Circuit Protective DevicesOutput Circuit NC - F Type Fuses 6 A
Output Circuit NO - F Type Fuses 10 A
Electrical DurabilityAC-12 100000 cycle
Mechanical DurabilityNr. Operations 30000000 cycle
Connecting CapacityFlexible with Ferrule 1x 0.5 ... 2.5 mm²
Flexible with Ferrule 2x 0.5 ... 1.5 mm²
Flexible with Insulated Ferrule 1x 0.5 ... 2.5 mm²
Flexible with Insulated Ferrule 2x 0.5 ... 1.5 mm²
Flexible 1x 0.5 ... 2.5 mm²
Flexible 2x 0.5 ... 1.5 mm²
Rigid 1x 0.5 ... 4 mm²
Rigid 2x 0.5 ... 2.5 mm²
Tightening Torque0.6 ... 0.8 N·m
Wire Stripping Length8 mm
Recommended Screw Driver0.8 x 4
4.5
Pozidriv 1
Mounting Position1 ... 6
Mounting on DIN RailTH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715
TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
StandardsCAN/CSA C22.2 No.14
IEC/EN 63000
IEC/EN 60255-27
IEC/EN 61000-6-2
IEC/EN 61000-6-3
UL 508
Technical UL/CSA
Maximum Operating Voltage UL/CSAOutput Circuit 300 V AC
Contact Rating UL/CSAB300
Connecting Capacity UL/CSAFlexible 1x 18-14 AWG
Flexible 2x 18-16 AWG
Rigid 1x 20-12 AWG
Rigid 2x 20-14 AWG
Tightening Torque UL/CSA7.08 in·lb
Pilot Duty UL/CSAB300
Flammability According to UL94V-0
Environmental
Ambient Air TemperatureOperation -25 ... +60 °C
Storage -40 ... +85 °C
Maximum Operating Altitude PermissibleWithout Derating 2000 m
Material Compliance
Conflict Minerals Reporting Template (CMRT)9AKK108467A5658
REACH Declaration1SVD981001-4501
RoHS Declaration1SVD981001-4401
SCIPa042ef4e-510e-46ff-9934-8a6fff7d1001 Germany
Simplified SCIP759f1cee-bf06-4581-84d4-f2f2d9917eda France
d0d69e47-8f74-455f-858e-db5fa342742d France
a1fd986b-4afd-40b8-a494-228cf8b05a5d Sweden
d51ab0ca-473e-457d-bb85-ee50b45470d6 Poland
2e2b7ea0-c13f-4ddb-8154-19f9ae551311 Germany
37c62a7f-c3ba-4f15-9440-c836a49eddc5 Sweden
adffa8da-ab26-42af-a7fa-01b1490fb42b Bulgaria
a58186e0-b506-46f7-952e-c442809fc350 Portugal
8e2c9124-8c49-44ae-99ec-f7596a65f063 Germany
2d9aab23-f2e0-4375-8ea4-875ffcfe4e86 Czech Republic
474c29b4-afb2-42dd-a08f-f8e16b4b77c3 Germany
7a06d04c-d459-4556-9147-f4c35b6bd003 Croatia
8b2266a3-2421-423b-afcd-65dce8476251 Hungary
1aff781e-4dde-4985-8512-a6233729d99a Netherlands
b1801f5a-60dd-4ffa-a66a-f054021654b4 Greece
bdecf2ff-0bee-4974-8c59-5aecee31c5b9 Poland
1916e3be-b0b8-4177-b25f-185b3bafce20 Estonia
c60fb120-63f6-4549-8d6f-1ecd313fea46 Belgium
fca056cf-20cf-48c1-8011-3d0386abd65e Hungary
1fadc248-2809-42dc-b4f1-ecf460a0d04b Spain
e75a967b-b786-459b-82d6-378ff85682ae Italy
a5d7b469-a49c-4b76-a5f9-a7f375df3e35 Germany
7a8c5423-8390-4146-bc64-5f338faf95d5 Belgium
81cee965-c3ec-41ce-9ad0-ca414853c1bb Denmark
de40734a-e8a4-4336-92b2-f300b68fafab Poland
525f5f6a-b36f-43c9-86c6-6afcd2465cbb Norway
bef6992c-39f4-48fc-aab4-60b68e112b1a Finland
Toxic Substances Control Act - TSCA2CMT2023-006536
ABB EcoSolutions
ABB EcoSolutionsYes
Environmental Product Declaration - EPD1SAC200438H0001
Certificates and Declarations
CQC CertificateCQC2009010303326655
cULus CertificatecULus508_20120829-E140448
Declaration of Conformity - CCC2020980303000197
Declaration of Conformity - CE1SVD981014-00
Declaration of Conformity - UKCA1SVD981014-10
DNV GL CertificateDNV_GL_TAA000017D
Container Information
Package Level 1 Unitsbox 1 piece
Package Level 1 Width97 mm
Package Level 1 Depth / Length30 mm
Package Level 1 Height109 mm
Package Level 1 Gross Weight0.158 kg
Package Level 1 EAN4016779851794
External Classifications and Standards
Object Classification CodeB
ETIM 7EC001441 - Phase monitoring relay
ETIM 8EC001441 - Phase monitoring relay
ETIM 9EC001441 - Phase monitoring relay
eClassV11.0 : 27371803
UNSPSC39122332
E-Number (Finland)2712282
E-Number (Norway)4188159
E-Number (Sweden)3860579

Product Datasheet

Electrica Online Product Datasheet Prepared from the current product description, catalog data and structured technical attributes.