ABB 1SVR730712R1300 1SVR730712R1300 ABB CM-MSS.51S Therm. motor protec. relay 2x1c/o, 24-240VAC/DC View larger
Images are for illustrative purposes only. Please refer to data sheet for details

1SVR730712R1300 ABB CM-MSS.51S Therm. motor protec. relay 2x1c/o, 24-240VAC/DC

1SVR730712R1300

730712

ABB

1 Pcs.

CM-MSS.51S Therm. motor protec. relay 2x1c/o, 24-240VAC/DC CM-MSS.51S MOTOR CONTROL RELAY x PTC

Automation > Relay for thermistor protection (PTC)
Monitoring

Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.

Request a Quote

Pricing and availability are confirmed for each enquiry. Add your required quantity to begin.

No account, online checkout or payment is required.

More info

Ordering
EAN4013614496660
Minimum Order Quantity1 piece
Customs Tariff Number85364900
Popular Downloads
Data Sheet, Technical Information2CDC112214D0201
Instructions and Manuals1SVC730700M1000
1SVC730700M0000
Ex Operating Instructions1SVC730640M9000
CAD Dimensional Drawing2CDC001079B0201
EPLAN Data9AAC132589_EPLAN
Dimensions
Product Net Width22.5 mm
Product Net Height85.6 mm
Product Net Depth / Length103.7 mm
Product Net Weight0.145 kg
Technical
Function2 sensor circuits
Auto, manual or remote reset
ATEX approved
Dynamic interrupted wire detection
Short-circuit detection, configurable
Non-volatile fault storage, configurable
Single or accumulative evalutation, configurable
Rated Control Supply Voltage (Us)24 ... 240 V AC/DC
Rated Operational VoltageAuxiliary Circuit 250 V AC
Rated Frequency (f)Supply Circuit 15 ... 400 Hz
Output2x 1 C/O or 1x 2 C/O Contact, Configurable
Terminal TypeScrew Terminals
Rated Operational Current AC-12 (Ie)(230 V) 4 A
Rated Operational Current AC-15 (Ie)(230 V) 3 A
Rated Operational Current DC-12 (Ie)(24 V) 4 A
Rated Operational Current DC-13 (Ie)(24 V) 2 A
Minimum Switching Capacity24 V
10 mA
Rated Impulse Withstand Voltage (Uimp)Output Circuit 1 / Output Circuit 2 4 kV
Output Circuit 4 kV
Rated Insulation Voltage (Ui)Measuring Circuit / Output Circuit 300 V
Output Circuit 1 / Output Circuit 2 300 V
Supply Circuit / Measuring Circuit 300 V
Supply Circuit / Output Circuit 300 V
Degree of ProtectionHousing IP50
Terminals IP20
Overvoltage CategoryIII
Pollution Degree3
Short-Circuit Protective DevicesOutput Circuit NC - F Type Fuses 6 A
Output Circuit NO - F Type Fuses 10 A
Electrical DurabilityAC-12 100000 cycle
Mechanical DurabilityNr. Operations 30000000 cycle
Connecting CapacityFlexible 1x 0.5 ... 2.5 mm²
Flexible 2x 0.5 ... 1.5 mm²
Rigid 1x 0.5 ... 4 mm²
Rigid 2x 0.5 ... 2.5 mm²
Tightening Torque0.6 ... 0.8 N·m
Wire Stripping Length8 mm
Recommended Screw Driver4.5
0.8 x 4
Pozidriv 1
Mounting Position1 ... 6
Mounting on DIN RailTH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715
StandardsCAN/CSA C22.2 No.14
EN 50495
IEC/EN 63000
IEC/EN 60079-7
IEC/EN 60947-5-1
IEC/EN 60947-8
UL 508
Technical UL/CSA
Maximum Operating Voltage UL/CSAOutput Circuit 300 V AC
Contact Rating UL/CSAB300
Connecting Capacity UL/CSAFlexible 1x 18-14 AWG
Flexible 2x 18-16 AWG
Rigid 2x 20-14 AWG
Rigid 1x 20-12 AWG
Tightening Torque UL/CSA7.08 in·lb
Pilot Duty UL/CSAB300
Flammability According to UL94V-0
Environmental
Ambient Air TemperatureOperation -25 ... +60 °C
Storage -40 ... +85 °C
Maximum Operating Altitude PermissibleWithout Derating 2000 m
Material Compliance
Conflict Minerals Reporting Template (CMRT)9AKK108467A5658
REACH Declaration1SVD981001-4501
RoHS Declaration1SVD981001-4401
SCIP3d345ed3-b7f8-4946-99de-7641bd8cff53 Germany
Simplified SCIP1c1432f7-69ed-4a3f-a6e2-d0cb78e195de Poland
75497ef8-3aec-403d-8f14-b4c3d2eccf91 Netherlands
c400ba75-1fff-438b-a391-666530a1d564 Estonia
1deb9e0b-8666-4121-bbf7-a6677959a24c Greece
7bee2972-fd3c-493a-ab11-6d4dd7c06def Italy
e796b62e-23bd-45af-81fe-c6147610666a Poland
f727fa0e-74e1-4e21-abf8-94eb05c2cbb4 Denmark
e01aba73-15dd-44bd-89ac-1a45f3c732fc Finland
c5abd88d-b92b-4a04-a0c7-30d2161dfcef Norway
81e51103-138d-4218-9be9-74af3d372271 Belgium
ce977453-5eea-478c-a573-e2fcabc67d67 Germany
d1c3f570-32c9-4146-b609-6fb2b005fc1f Germany
7f796499-254f-421d-b262-0169f7d11839 Croatia
759177ad-c955-461a-ad0a-f536c6dc2fe3 Czech Republic
1467679e-0a5a-4d39-8122-67ce4588cf07 Germany
7f7c2c5a-998d-47d0-b82d-a3fe9cfd7da7 Sweden
82843d97-34f2-47c2-bc9f-edb31fffaea0 Portugal
daa28a83-7d3b-4486-8021-716fcb8f727a Germany
7ba4f435-8353-4ba0-ac02-d720e6797a4b Bulgaria
5836d50a-9d5c-4de2-b5b1-191f05b1b697 Sweden
6d502d0f-5224-4ef1-b2ea-6b9a0967fc0d France
fdde98b0-c997-4b5b-a224-81a6b61c1e2a Poland
71cc20bc-38e8-45a8-9bd3-91dd7a5d9d8d France
04ee5fbf-197b-4747-8825-23514f5b8eb0 Hungary
0646f414-63b6-47b1-bb64-cb91288a3d64 Belgium
430507d3-b28e-4527-b7e7-a7902a3f65ba Spain
8e07458f-a937-4f60-a3d9-35de51cf9864 Hungary
Toxic Substances Control Act - TSCA2CMT2023-006536
ABB EcoSolutions
ABB EcoSolutionsYes
Environmental Product Declaration - EPD1SAC200438H0001
Certificates and Declarations
ATEX CertificateEU Type Examination Certificate_TPS_18_ATEX_044254_0018_X
CB CertificateCB_DK-40837-UL
CCC CertificateCCC_2005010303165479
CQC CertificateCQC2005010303165479
cULus CertificatecULus508_20140912-E140448
Declaration of Conformity - CCC2020980303000194
Declaration of Conformity - CE1SVD981007
Declaration of Conformity - UKCA1SVD981007-10
DNV GL CertificateDNVGL_TAE00003W4
Container Information
Package Level 1 Unitsbox 1 piece
Package Level 1 Width97 mm
Package Level 1 Depth / Length30 mm
Package Level 1 Height109 mm
Package Level 1 Gross Weight0.172 kg
Package Level 1 EAN4013614496660
External Classifications and Standards
Object Classification CodeB
ETIM 7EC002568 - Relay for thermistor protection (PTC)
ETIM 8EC002568 - Relay for thermistor protection (PTC)
ETIM 9EC002568 - Relay for thermistor protection (PTC)
eClassV11.0 : 27371503
UNSPSC39122331
E-Number (Finland)2712514
E-Number (Norway)4185874
E-Number (Sweden)3860777

Product Datasheet