View larger
1SVR740712R2200
740712
ABB
1 Pcs.
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
| Ordering | |
|---|---|
| EAN | 4013614496530 |
| Minimum Order Quantity | 1 piece |
| Customs Tariff Number | 85364900 |
| Popular Downloads | |
| Data Sheet, Technical Information | 2CDC112221D0201 |
| Instructions and Manuals | 1SVC730700M1000 |
| 1SVC730700M0000 | |
| Ex Operating Instructions | 1SVC730640M9000 |
| CAD Dimensional Drawing | 2CDC001079B0201 |
| EPLAN Data | 9AAC132589_EPLAN |
| Dimensions | |
| Product Net Width | 22.5 mm |
| Product Net Height | 85.6 mm |
| Product Net Depth / Length | 103.7 mm |
| Product Net Weight | 0.162 kg |
| Technical | |
| Function | 1 sensor circuit |
| Short-circuit detection | |
| Dynamic interrupted wire detection | |
| Auto | |
| manual or remote reset | |
| ATEX approved | |
| Rated Control Supply Voltage (Us) | 110 ... 130 V AC |
| 220 ... 240 V AC | |
| Rated Operational Voltage | Auxiliary Circuit 250 V AC |
| Rated Frequency (f) | Supply Circuit 50/60 Hz |
| Output | 2 C/O Contacts |
| Terminal Type | Screwless Terminals |
| Rated Operational Current AC-12 (Ie) | (230 V) 4 A |
| Rated Operational Current AC-15 (Ie) | (230 V) 3 A |
| Rated Operational Current DC-12 (Ie) | (24 V) 4 A |
| Rated Operational Current DC-13 (Ie) | (24 V) 2 A |
| Minimum Switching Capacity | 24 V |
| 10 mA | |
| Rated Impulse Withstand Voltage (Uimp) | Output Circuit 1 / Output Circuit 2 4 kV |
| Output Circuit 4 kV | |
| Rated Insulation Voltage (Ui) | Measuring Circuit / Output Circuit 300 V |
| Output Circuit 1 / Output Circuit 2 300 V | |
| Supply Circuit / Measuring Circuit 300 V | |
| Supply Circuit / Output Circuit 300 V | |
| Degree of Protection | Housing IP50 |
| Terminals IP20 | |
| Overvoltage Category | III |
| Pollution Degree | 3 |
| Short-Circuit Protective Devices | Output Circuit NC - F Type Fuses 10 A |
| Output Circuit NO - F Type Fuses 10 A | |
| Electrical Durability | AC-12 100000 cycle |
| Mechanical Durability | Nr. Operations 30000000 cycle |
| Connecting Capacity | Flexible 2x 0.5 ... 1.5 mm² |
| Rigid 2x 0.5 ... 1.5 mm² | |
| Wire Stripping Length | 8 mm |
| Mounting Position | 1 ... 6 |
| Mounting on DIN Rail | TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715 |
| TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715 | |
| Standards | CAN/CSA C22.2 No.14 |
| EN 50495 | |
| IEC/EN 63000 | |
| IEC/EN 60079-7 | |
| IEC/EN 60947-5-1 | |
| IEC/EN 60947-8 | |
| UL 508 | |
| Technical UL/CSA | |
| Maximum Operating Voltage UL/CSA | Output Circuit 300 V AC |
| Contact Rating UL/CSA | B300 |
| Connecting Capacity UL/CSA | Flexible 2x 18-16 AWG |
| Rigid 2x 20-16 AWG | |
| Pilot Duty UL/CSA | B300 |
| Flammability According to UL94 | V-0 |
| Environmental | |
| Ambient Air Temperature | Operation -25 ... +60 °C |
| Storage -40 ... +85 °C | |
| Maximum Operating Altitude Permissible | Without Derating 2000 m |
| Material Compliance | |
| Conflict Minerals Reporting Template (CMRT) | 9AKK108467A5658 |
| REACH Declaration | 1SVD981001-4501 |
| RoHS Declaration | 1SVD981001-4401 |
| SCIP | b275c9ae-19d0-44ea-959b-d81110b146f0 Germany |
| Simplified SCIP | 0a94a71a-0ba2-423e-b5f2-47bea6d63748 Bulgaria |
| 1e815819-304a-434b-a1c5-8950c3ab29b3 Germany | |
| 2b96fd87-4ff7-4fff-955e-f0bde04b4899 Belgium | |
| 3fb546ed-533f-445d-ab00-0422c61b34dd Hungary | |
| 44b1fe30-43dd-493e-ba71-2d6c34a2cad9 Sweden | |
| 4b393ff9-2b06-4a5a-a326-d77d662f5253 Sweden | |
| 4c759303-679b-46d3-8a50-7abc53ccef10 Germany | |
| 53f78cba-101e-4425-a1bb-704b83acfcb2 France | |
| 65dcdb4a-4f55-4473-9ff4-e37729a47b79 Estonia | |
| 678cf6bb-acc7-4bb0-a929-e1bc3908e775 Hungary | |
| 69197f28-18bf-4cbc-ad12-550e77070572 Portugal | |
| 7e6f246a-0b95-4e99-a68d-0cd300f1a442 France | |
| 8d9bfb72-bb69-433f-bec9-4c9282e85652 Spain | |
| 94d86c79-5275-48c6-8f69-48d8f7c5747e Denmark | |
| 9682ee49-0100-4d23-870a-e21864da565f Norway | |
| a752e950-3a48-4b7d-858e-deb0287007c7 Croatia | |
| a88d9b4d-c5db-4a9a-bec5-f3e6b80e5baf Poland | |
| ac8d58f1-980b-4387-9b2d-358acbce42f2 Italy | |
| b8990ec1-2777-4f62-b07b-08291ba1edcb Greece | |
| bb6772d5-f03c-4664-945c-3e8ea443000d Germany | |
| bb8f49f6-d6b3-4497-8865-f715fe26c1e1 Belgium | |
| bfaba63a-c9df-4ac6-be48-c34e1b9a23b4 Germany | |
| c50af463-a9c9-4c08-9f4e-694a9031a923 Poland | |
| c757c905-db46-4bda-8ccb-566234d26089 Finland | |
| d744fdcd-2071-4fc5-8e76-06fb120cf0cd Czech Republic | |
| df75a101-424c-4322-974b-f97997e7b6e4 Poland | |
| fbd2b15b-7902-44fa-b9d3-b2f856460f51 Netherlands | |
| Toxic Substances Control Act - TSCA | 2CMT2023-006536 |
| ABB EcoSolutions | |
| Environmental Product Declaration - EPD | 1SAC200438H0001 |
| Certificates and Declarations | |
| ATEX Certificate | EU Type Examination Certificate_TPS_18_ATEX_044254_0018_X |
| CB Certificate | CB_DK-40837-UL |
| CCC Certificate | CCC_2005010303165479 |
| CQC Certificate | CQC2005010303165479 |
| cULus Certificate | cULus508_20140912-E140448 |
| Declaration of Conformity - CCC | 2020980303000194 |
| Declaration of Conformity - CE | 1SVD981007 |
| Declaration of Conformity - UKCA | 1SVD981007-10 |
| DNV GL Certificate | DNVGL_TAE00003W4 |
| Container Information | |
| Package Level 1 Units | box 1 piece |
| Package Level 1 Width | 97 mm |
| Package Level 1 Depth / Length | 30 mm |
| Package Level 1 Height | 109 mm |
| Package Level 1 Gross Weight | 0.188 kg |
| Package Level 1 EAN | 4013614496530 |
| External Classifications and Standards | |
| Object Classification Code | B |
| ETIM 7 | EC002568 - Relay for thermistor protection (PTC) |
| ETIM 8 | EC002568 - Relay for thermistor protection (PTC) |
| ETIM 9 | EC002568 - Relay for thermistor protection (PTC) |
| eClass | V11.0 : 27371503 |
| UNSPSC | 39122331 |
| E-Number (Finland) | 2712509 |
| E-Number (Norway) | 4188183 |
| E-Number (Sweden) | 3860735 |