ABB 1SVR740712R2200 1SVR740712R2200 ABB CM-MSS.33P Therm. motor protec. relay 2c/o, 110-130VAC/220-240VAC View larger
Images are for illustrative purposes only. Please refer to data sheet for details

1SVR740712R2200 ABB CM-MSS.33P Therm. motor protec. relay 2c/o, 110-130VAC/220-240VAC

1SVR740712R2200

740712

ABB

1 Pcs.

CM-MSS.33P Therm. motor protec. relay 2c/o, 110-130VAC/220-240VAC CM-MSS.33P MOTOR CONTROL RELAY x PTC

Automation > Relay for thermistor protection (PTC)
Monitoring

Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.

Request a Quote

Pricing and availability are confirmed for each enquiry. Add your required quantity to begin.

No account, online checkout or payment is required.

More info

Ordering
EAN4013614496530
Minimum Order Quantity1 piece
Customs Tariff Number85364900
Popular Downloads
Data Sheet, Technical Information2CDC112221D0201
Instructions and Manuals1SVC730700M1000
1SVC730700M0000
Ex Operating Instructions1SVC730640M9000
CAD Dimensional Drawing2CDC001079B0201
EPLAN Data9AAC132589_EPLAN
Dimensions
Product Net Width22.5 mm
Product Net Height85.6 mm
Product Net Depth / Length103.7 mm
Product Net Weight0.162 kg
Technical
Function1 sensor circuit
Short-circuit detection
Dynamic interrupted wire detection
Auto
manual or remote reset
ATEX approved
Rated Control Supply Voltage (Us)110 ... 130 V AC
220 ... 240 V AC
Rated Operational VoltageAuxiliary Circuit 250 V AC
Rated Frequency (f)Supply Circuit 50/60 Hz
Output2 C/O Contacts
Terminal TypeScrewless Terminals
Rated Operational Current AC-12 (Ie)(230 V) 4 A
Rated Operational Current AC-15 (Ie)(230 V) 3 A
Rated Operational Current DC-12 (Ie)(24 V) 4 A
Rated Operational Current DC-13 (Ie)(24 V) 2 A
Minimum Switching Capacity24 V
10 mA
Rated Impulse Withstand Voltage (Uimp)Output Circuit 1 / Output Circuit 2 4 kV
Output Circuit 4 kV
Rated Insulation Voltage (Ui)Measuring Circuit / Output Circuit 300 V
Output Circuit 1 / Output Circuit 2 300 V
Supply Circuit / Measuring Circuit 300 V
Supply Circuit / Output Circuit 300 V
Degree of ProtectionHousing IP50
Terminals IP20
Overvoltage CategoryIII
Pollution Degree3
Short-Circuit Protective DevicesOutput Circuit NC - F Type Fuses 10 A
Output Circuit NO - F Type Fuses 10 A
Electrical DurabilityAC-12 100000 cycle
Mechanical DurabilityNr. Operations 30000000 cycle
Connecting CapacityFlexible 2x 0.5 ... 1.5 mm²
Rigid 2x 0.5 ... 1.5 mm²
Wire Stripping Length8 mm
Mounting Position1 ... 6
Mounting on DIN RailTH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715
TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
StandardsCAN/CSA C22.2 No.14
EN 50495
IEC/EN 63000
IEC/EN 60079-7
IEC/EN 60947-5-1
IEC/EN 60947-8
UL 508
Technical UL/CSA
Maximum Operating Voltage UL/CSAOutput Circuit 300 V AC
Contact Rating UL/CSAB300
Connecting Capacity UL/CSAFlexible 2x 18-16 AWG
Rigid 2x 20-16 AWG
Pilot Duty UL/CSAB300
Flammability According to UL94V-0
Environmental
Ambient Air TemperatureOperation -25 ... +60 °C
Storage -40 ... +85 °C
Maximum Operating Altitude PermissibleWithout Derating 2000 m
Material Compliance
Conflict Minerals Reporting Template (CMRT)9AKK108467A5658
REACH Declaration1SVD981001-4501
RoHS Declaration1SVD981001-4401
SCIPb275c9ae-19d0-44ea-959b-d81110b146f0 Germany
Simplified SCIP0a94a71a-0ba2-423e-b5f2-47bea6d63748 Bulgaria
1e815819-304a-434b-a1c5-8950c3ab29b3 Germany
2b96fd87-4ff7-4fff-955e-f0bde04b4899 Belgium
3fb546ed-533f-445d-ab00-0422c61b34dd Hungary
44b1fe30-43dd-493e-ba71-2d6c34a2cad9 Sweden
4b393ff9-2b06-4a5a-a326-d77d662f5253 Sweden
4c759303-679b-46d3-8a50-7abc53ccef10 Germany
53f78cba-101e-4425-a1bb-704b83acfcb2 France
65dcdb4a-4f55-4473-9ff4-e37729a47b79 Estonia
678cf6bb-acc7-4bb0-a929-e1bc3908e775 Hungary
69197f28-18bf-4cbc-ad12-550e77070572 Portugal
7e6f246a-0b95-4e99-a68d-0cd300f1a442 France
8d9bfb72-bb69-433f-bec9-4c9282e85652 Spain
94d86c79-5275-48c6-8f69-48d8f7c5747e Denmark
9682ee49-0100-4d23-870a-e21864da565f Norway
a752e950-3a48-4b7d-858e-deb0287007c7 Croatia
a88d9b4d-c5db-4a9a-bec5-f3e6b80e5baf Poland
ac8d58f1-980b-4387-9b2d-358acbce42f2 Italy
b8990ec1-2777-4f62-b07b-08291ba1edcb Greece
bb6772d5-f03c-4664-945c-3e8ea443000d Germany
bb8f49f6-d6b3-4497-8865-f715fe26c1e1 Belgium
bfaba63a-c9df-4ac6-be48-c34e1b9a23b4 Germany
c50af463-a9c9-4c08-9f4e-694a9031a923 Poland
c757c905-db46-4bda-8ccb-566234d26089 Finland
d744fdcd-2071-4fc5-8e76-06fb120cf0cd Czech Republic
df75a101-424c-4322-974b-f97997e7b6e4 Poland
fbd2b15b-7902-44fa-b9d3-b2f856460f51 Netherlands
Toxic Substances Control Act - TSCA2CMT2023-006536
ABB EcoSolutions
Environmental Product Declaration - EPD1SAC200438H0001
Certificates and Declarations
ATEX CertificateEU Type Examination Certificate_TPS_18_ATEX_044254_0018_X
CB CertificateCB_DK-40837-UL
CCC CertificateCCC_2005010303165479
CQC CertificateCQC2005010303165479
cULus CertificatecULus508_20140912-E140448
Declaration of Conformity - CCC2020980303000194
Declaration of Conformity - CE1SVD981007
Declaration of Conformity - UKCA1SVD981007-10
DNV GL CertificateDNVGL_TAE00003W4
Container Information
Package Level 1 Unitsbox 1 piece
Package Level 1 Width97 mm
Package Level 1 Depth / Length30 mm
Package Level 1 Height109 mm
Package Level 1 Gross Weight0.188 kg
Package Level 1 EAN4013614496530
External Classifications and Standards
Object Classification CodeB
ETIM 7EC002568 - Relay for thermistor protection (PTC)
ETIM 8EC002568 - Relay for thermistor protection (PTC)
ETIM 9EC002568 - Relay for thermistor protection (PTC)
eClassV11.0 : 27371503
UNSPSC39122331
E-Number (Finland)2712509
E-Number (Norway)4188183
E-Number (Sweden)3860735

Product Datasheet

Electrica Online Product Datasheet Prepared from the current product description, catalog data and structured technical attributes.