View larger
1SVR740712R1400
740712
ABB
1 Pcs.
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
| Ordering | |
|---|---|
| EAN | 4013614496547 |
| Minimum Order Quantity | 1 piece |
| Customs Tariff Number | 85364900 |
| Popular Downloads | |
| Data Sheet, Technical Information | 2CDC112217D0201 |
| Instructions and Manuals | 1SVC730700M1000 |
| 1SVC730700M0000 | |
| Ex Operating Instructions | 1SVC730640M9000 |
| CAD Dimensional Drawing | 2CDC001079B0201 |
| EPLAN Data | 9AAC132589_EPLAN |
| Dimensions | |
| Product Net Width | 22.5 mm |
| Product Net Height | 85.6 mm |
| Product Net Depth / Length | 103.7 mm |
| Product Net Weight | 0.12 kg |
| Technical | |
| Function | 1 sensor circuit |
| Auto, manual or remote reset | |
| Short-circuit detection | |
| ATEX approved | |
| Dynamic interrupted wire detection | |
| Non-volatile fault storage | |
| Rated Control Supply Voltage (Us) | 24 ... 240 V AC/DC |
| Rated Operational Voltage | Auxiliary Circuit 250 V AC |
| Rated Frequency (f) | Supply Circuit 15 ... 400 Hz |
| Output | 1 N/O, 1 N/C Contact |
| Terminal Type | Screwless Terminals |
| Rated Operational Current AC-12 (Ie) | (230 V) 4 A |
| Rated Operational Current AC-15 (Ie) | (230 V) 3 A |
| Rated Operational Current DC-12 (Ie) | (24 V) 4 A |
| Rated Operational Current DC-13 (Ie) | (24 V) 2 A |
| Minimum Switching Capacity | 24 V |
| 10 mA | |
| Rated Impulse Withstand Voltage (Uimp) | Output Circuit 1 / Output Circuit 2 4 kV |
| Output Circuit 4 kV | |
| Rated Insulation Voltage (Ui) | Measuring Circuit / Output Circuit 300 V |
| Output Circuit 1 / Output Circuit 2 300 V | |
| Supply Circuit / Measuring Circuit 300 V | |
| Supply Circuit / Output Circuit 300 V | |
| Degree of Protection | Housing IP50 |
| Terminals IP20 | |
| Overvoltage Category | III |
| Pollution Degree | 3 |
| Short-Circuit Protective Devices | Output Circuit NC - F Type Fuses 10 A |
| Output Circuit NO - F Type Fuses 10 A | |
| Electrical Durability | AC-12 100000 cycle |
| Mechanical Durability | Nr. Operations 30000000 cycle |
| Connecting Capacity | Flexible 2x 0.5 ... 1.5 mm² |
| Rigid 2x 0.5 ... 1.5 mm² | |
| Wire Stripping Length | 8 mm |
| Mounting Position | 1 ... 6 |
| Mounting on DIN Rail | TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715 |
| TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715 | |
| Standards | CAN/CSA C22.2 No.14 |
| EN 50495 | |
| IEC/EN 63000 | |
| IEC/EN 60079-7 | |
| IEC/EN 60947-5-1 | |
| IEC/EN 60947-8 | |
| UL 508 | |
| Technical UL/CSA | |
| Maximum Operating Voltage UL/CSA | Output Circuit 300 V AC |
| Contact Rating UL/CSA | B300 |
| Connecting Capacity UL/CSA | Flexible 2x 18-16 AWG |
| Rigid 2x 20-16 AWG | |
| Pilot Duty UL/CSA | B300 |
| Flammability According to UL94 | V-0 |
| Environmental | |
| Ambient Air Temperature | Operation -25 ... +60 °C |
| Storage -40 ... +85 °C | |
| Maximum Operating Altitude Permissible | Without Derating 2000 m |
| Material Compliance | |
| Conflict Minerals Reporting Template (CMRT) | 9AKK108467A5658 |
| REACH Declaration | 1SVD981001-4501 |
| RoHS Declaration | 1SVD981001-4401 |
| SCIP | 9a81bc75-ccaf-4044-968a-81357ee63324 Germany |
| Simplified SCIP | 1e438b34-fa67-4ea3-be46-b0853a618b0e Germany |
| 367ea5d7-8e41-4bdf-85cd-e046e2f4f259 Germany | |
| 3edf5420-7b76-4ecf-9f3d-430e4bc6d3e9 Belgium | |
| 401aa8cf-58db-40da-a35c-791dd5e41b00 Hungary | |
| 41626885-36a2-4fe9-98fd-d1c611006633 Sweden | |
| 4c00e90c-d330-45be-869a-a7884b658132 Sweden | |
| 584d6f31-e73a-41b1-9aae-29819a39b276 Estonia | |
| 5c60c4f6-93a9-44b5-a341-99cc443a4a13 France | |
| 7835d22d-a72c-4c84-a92d-2194f176c30c Bulgaria | |
| 858acf32-73dd-44b4-acb6-fbbf46e088eb Denmark | |
| 915c0569-fa5c-48ee-b263-0f2a776e4d0f Norway | |
| 95db8337-b9c9-47ea-bcc0-1194ba57fcbb France | |
| 99fc9dce-c528-4f5c-b239-9de2f9df20d3 Finland | |
| 9df14a3a-a979-49f6-9a0f-768c1949e984 Germany | |
| a0f9b5b7-a521-4b8e-8de5-40486fb8b7b2 Belgium | |
| a21fb683-0681-4bbe-968e-7952f081251a Poland | |
| a75e85bc-f9c3-46d3-b408-0800161614b0 Germany | |
| b4ed5746-c570-41db-820f-76744a40a2dd Poland | |
| bd7d036c-fab9-4407-bded-b8468beeb880 Greece | |
| c5e3934a-57fa-4068-b08a-e044d222fd8f Netherlands | |
| c907814b-8c54-4f16-91cc-da8627cd36ea Hungary | |
| dad40399-ed6e-4bd9-b573-bf46f947e42f Poland | |
| e0f23534-6691-42ed-a266-00618b475841 Spain | |
| e3faad24-827d-47f0-ae44-9f39c9b244fd Portugal | |
| e544d888-ebe6-4e91-983a-ce39c0243e41 Croatia | |
| f2567045-bcf8-49ba-b8bb-c73bb15180e2 Italy | |
| fdf77cec-0372-4d1f-944f-ecca86e8fb7d Czech Republic | |
| Toxic Substances Control Act - TSCA | 2CMT2023-006536 |
| ABB EcoSolutions | |
| Environmental Product Declaration - EPD | 1SAC200438H0001 |
| Certificates and Declarations | |
| ATEX Certificate | EU Type Examination Certificate_TPS_18_ATEX_044254_0018_X |
| CB Certificate | CB_DK-40837-UL |
| CCC Certificate | CCC_2005010303165479 |
| CQC Certificate | CQC2005010303165479 |
| cULus Certificate | cULus508_20140912-E140448 |
| Declaration of Conformity - CCC | 2020980303000194 |
| Declaration of Conformity - CE | 1SVD981007 |
| Declaration of Conformity - UKCA | 1SVD981007-10 |
| DNV GL Certificate | DNVGL_TAE00003W4 |
| Container Information | |
| Package Level 1 Units | box 1 piece |
| Package Level 1 Width | 97 mm |
| Package Level 1 Depth / Length | 30 mm |
| Package Level 1 Height | 109 mm |
| Package Level 1 Gross Weight | 0.146 kg |
| Package Level 1 EAN | 4013614496547 |
| External Classifications and Standards | |
| Object Classification Code | B |
| ETIM 7 | EC002568 - Relay for thermistor protection (PTC) |
| ETIM 8 | EC002568 - Relay for thermistor protection (PTC) |
| ETIM 9 | EC002568 - Relay for thermistor protection (PTC) |
| eClass | V11.0 : 27371503 |
| UNSPSC | 39122331 |
| E-Number (Finland) | 2712505 |
| E-Number (Norway) | 4188182 |
| E-Number (Sweden) | 3860727 |