ABB 1SVR730700R0200 1SVR730700R0200 ABB CM-MSS.22S Therm. motor protec. relay 2c/o, 24VAC/DC View larger
Images are for illustrative purposes only. Please refer to data sheet for details

1SVR730700R0200 ABB CM-MSS.22S Therm. motor protec. relay 2c/o, 24VAC/DC

1SVR730700R0200

730700

ABB

1 Pcs.

CM-MSS.22S Therm. motor protec. relay 2c/o, 24VAC/DC CM-MSS.22S MOTOR CONTROL RELAY x PTC

Automation > Relay for thermistor protection (PTC)
Monitoring

Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.

Request a Quote

Pricing and availability are confirmed for each enquiry. Add your required quantity to begin.

No account, online checkout or payment is required.

More info

Ordering
EAN4013614496714
Minimum Order Quantity1 piece
Customs Tariff Number85364900
Popular Downloads
Data Sheet, Technical Information2CDC112220D0201
Instructions and Manuals1SVC730700M1000
1SVC730700M0000
CAD Dimensional Drawing2CDC001079B0201
EPLAN Data9AAC132589_EPLAN
Dimensions
Product Net Width22.5 mm
Product Net Height85.6 mm
Product Net Depth / Length103.7 mm
Product Net Weight0.132 kg
Technical
Function1 sensor circuit
Auto
manual or remote reset
Rated Control Supply Voltage (Us)24 V AC/DC
Rated Operational VoltageAuxiliary Circuit 250 V AC
Rated Frequency (f)Supply Circuit 50/60 Hz
Output2 C/O Contacts
Terminal TypeScrew Terminals
Rated Operational Current AC-12 (Ie)(230 V) 4 A
Rated Operational Current AC-15 (Ie)(230 V) 3 A
Rated Operational Current DC-12 (Ie)(24 V) 4 A
Rated Operational Current DC-13 (Ie)(24 V) 2 A
Minimum Switching Capacity24 V
10 mA
Rated Impulse Withstand Voltage (Uimp)Output Circuit 1 / Output Circuit 2 4 kV
Output Circuit 4 kV
Rated Insulation Voltage (Ui)Measuring Circuit / Output Circuit 300 V
Output Circuit 1 / Output Circuit 2 300 V
Supply Circuit / Output Circuit 300 V
Degree of ProtectionHousing IP50
Terminals IP20
Overvoltage CategoryIII
Pollution Degree3
Short-Circuit Protective DevicesOutput Circuit NC - F Type Fuses 10 A
Output Circuit NO - F Type Fuses 10 A
Electrical DurabilityAC-12 100000 cycle
Mechanical DurabilityNr. Operations 30000000 cycle
Connecting CapacityFlexible 1x 0.5 ... 2.5 mm²
Flexible 2x 0.5 ... 1.5 mm²
Rigid 1x 0.5 ... 4 mm²
Rigid 2x 0.5 ... 2.5 mm²
Tightening Torque0.6 ... 0.8 N·m
Wire Stripping Length8 mm
Recommended Screw Driver0.8 x 4
4.5
Pozidriv 1
Mounting Position1 ... 6
Mounting on DIN RailTH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715
TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
StandardsCAN/CSA C22.2 No.14
IEC/EN 63000
IEC/EN 60947-5-1
IEC/EN 60947-8
UL 508
Technical UL/CSA
Maximum Operating Voltage UL/CSAOutput Circuit 300 V AC
Contact Rating UL/CSAB300
Connecting Capacity UL/CSAFlexible 1x 18-14 AWG
Flexible 2x 18-16 AWG
Rigid 1x 20-12 AWG
Rigid 2x 20-14 AWG
Tightening Torque UL/CSA7.08 in·lb
Pilot Duty UL/CSAB300
Flammability According to UL94V-0
Environmental
Ambient Air TemperatureOperation -25 ... +60 °C
Storage -40 ... +85 °C
Maximum Operating Altitude PermissibleWithout Derating 2000 m
Material Compliance
Conflict Minerals Reporting Template (CMRT)9AKK108467A5658
REACH Declaration1SVD981001-4501
RoHS Declaration1SVD981001-4401
SCIP991bb91c-7b72-4a3e-bfe2-06d4dad60102 Germany
Simplified SCIP587edf96-5c9a-4865-b9a0-c7922442eb66 Germany
145c443d-b1bc-46ac-8d02-efa5a45ccdbe France
fd3e6849-7017-4ae8-b70d-8d6488d64373 Hungary
a2c0e89b-8cc1-4ed1-8acb-c9920272a4c4 Belgium
91fbac72-341b-4524-a1b3-2db479df9529 Portugal
3c9ff200-d6e6-4751-83b9-9ab26d7714cd Germany
ac6d8327-ccb6-4e90-9b11-3e63e85863a5 Sweden
72f013c0-c347-42c2-8dd5-44d84797d0b9 France
0e81272b-8adc-40cf-a8e6-b3316ee51f17 Spain
629430e3-e0f8-43fd-95c2-4dcfaf6cb6ca Estonia
dabb2ed6-b9d6-4479-82ce-6212d3b69f6b Sweden
516b31cf-e802-4bb9-9a5e-71a982a3e0f4 Poland
1c617828-a340-4b2b-bd42-c862fdb4d95a Poland
17610ba6-92d5-4ca4-831f-d64bba3e9f96 Norway
f421b743-52ad-40e4-8595-8f96f2abb371 Croatia
14da33f5-72ed-4e04-aefa-82badad7705a Czech Republic
9db619e0-bda7-4a72-82c7-2bfe78f5f0d0 Germany
f4f25c91-ea84-475e-9e0e-64f43c17b911 Poland
c5af4d47-57e8-492e-8f59-dea76a3f20b1 Denmark
c6452b92-76e3-46e5-aecb-2a50bbe65fed Italy
4a99599d-8250-4824-ae58-dbb675fec96f Germany
cf3e49c8-92b6-4676-b70d-f0ba790768ec Netherlands
61282ef0-62a3-4e5c-9e1d-1a9124ea2239 Greece
5eb83f2a-e59f-41c8-a7b9-ca530e26e357 Hungary
7bf31848-ae57-4c8a-a036-392de82e8442 Bulgaria
910d2c09-5244-49f8-8781-f382047ef676 Finland
c6ffeed5-2841-4645-a27f-ebb92c59efd5 Belgium
Toxic Substances Control Act - TSCA2CMT2023-006536
ABB EcoSolutions
ABB EcoSolutionsYes
Environmental Product Declaration - EPD1SAC200438H0001
Certificates and Declarations
CB CertificateCB_DK-40837-UL
CCC CertificateCCC_2005010303165479
CQC CertificateCQC2005010303165479
cULus CertificatecULus508_20140912-E140448
Declaration of Conformity - CCC2020980303000194
Declaration of Conformity - CE1SVD981006
Declaration of Conformity - UKCA1SVD981006-10
DNV GL CertificateDNVGL_TAE00003W4
Container Information
Package Level 1 Unitsbox 1 piece
Package Level 1 Width97 mm
Package Level 1 Depth / Length30 mm
Package Level 1 Height109 mm
Package Level 1 Gross Weight0.155 kg
Package Level 1 EAN4013614496714
External Classifications and Standards
Object Classification CodeB
ETIM 7EC002568 - Relay for thermistor protection (PTC)
ETIM 8EC002568 - Relay for thermistor protection (PTC)
ETIM 9EC002568 - Relay for thermistor protection (PTC)
eClassV11.0 : 27371503
UNSPSC39122331
E-Number (Finland)2712502
E-Number (Norway)4185881
E-Number (Sweden)3860724

Product Datasheet

Electrica Online Product Datasheet Prepared from the current product description, catalog data and structured technical attributes.