View larger
1SVR730722R1400
730722
ABB
1 Pcs.
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
| Ordering | |
|---|---|
| EAN | 4013614496622 |
| Minimum Order Quantity | 1 piece |
| Customs Tariff Number | 85364900 |
| Popular Downloads | |
| Data Sheet, Technical Information | 2CDC112218D0201 |
| Instructions and Manuals | 1SVC730700M1000 |
| 1SVC730700M0000 | |
| Ex Operating Instructions | 1SVC730640M9000 |
| CAD Dimensional Drawing | 2CDC001079B0201 |
| EPLAN Data | 9AAC132589_EPLAN |
| Dimensions | |
| Product Net Width | 22.5 mm |
| Product Net Height | 85.6 mm |
| Product Net Depth / Length | 103.7 mm |
| Product Net Weight | 0.126 kg |
| Technical | |
| Function | 1 sensor circuit |
| Short-circuit detection | |
| Auto reset | |
| ATEX approved | |
| Dynamic interrupted wire detection | |
| Non-volatile fault storage | |
| Rated Control Supply Voltage (Us) | 24 ... 240 V AC/DC |
| Rated Operational Voltage | Auxiliary Circuit 250 V AC |
| Rated Frequency (f) | Supply Circuit 15 ... 400 Hz |
| Output | 1 N/O, 1 N/C Contact |
| Terminal Type | Screw Terminals |
| Rated Operational Current AC-12 (Ie) | (230 V) 4 A |
| Rated Operational Current AC-15 (Ie) | (230 V) 3 A |
| Rated Operational Current DC-12 (Ie) | (24 V) 4 A |
| Rated Operational Current DC-13 (Ie) | (24 V) 2 A |
| Minimum Switching Capacity | 24 V |
| 10 mA | |
| Rated Impulse Withstand Voltage (Uimp) | Output Circuit 1 / Output Circuit 2 4 kV |
| Output Circuit 4 kV | |
| Rated Insulation Voltage (Ui) | Measuring Circuit / Output Circuit 300 V |
| Output Circuit 1 / Output Circuit 2 300 V | |
| Supply Circuit / Measuring Circuit 300 V | |
| Supply Circuit / Output Circuit 300 V | |
| Degree of Protection | Housing IP50 |
| Terminals IP20 | |
| Overvoltage Category | III |
| Pollution Degree | 3 |
| Short-Circuit Protective Devices | Output Circuit NC - F Type Fuses 10 A |
| Output Circuit NO - F Type Fuses 10 A | |
| Electrical Durability | AC-12 100000 cycle |
| Mechanical Durability | Nr. Operations 30000000 cycle |
| Connecting Capacity | Flexible 1x 0.5 ... 2.5 mm² |
| Flexible 2x 0.5 ... 1.5 mm² | |
| Rigid 1x 0.5 ... 4 mm² | |
| Rigid 2x 0.5 ... 2.5 mm² | |
| Tightening Torque | 0.6 ... 0.8 N·m |
| Wire Stripping Length | 8 mm |
| Recommended Screw Driver | 4.5 |
| 0.8 x 4 | |
| Pozidriv 1 | |
| Mounting Position | 1 ... 6 |
| Mounting on DIN Rail | TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715 |
| TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715 | |
| Standards | CAN/CSA C22.2 No.14 |
| EN 50495 | |
| IEC/EN 63000 | |
| IEC/EN 60079-7 | |
| IEC/EN 60947-5-1 | |
| IEC/EN 60947-8 | |
| UL 508 | |
| Technical UL/CSA | |
| Maximum Operating Voltage UL/CSA | Output Circuit 300 V AC |
| Contact Rating UL/CSA | B300 |
| Connecting Capacity UL/CSA | Flexible 1x 18-14 AWG |
| Flexible 2x 18-16 AWG | |
| Rigid 2x 20-14 AWG | |
| Rigid 1x 20-12 AWG | |
| Tightening Torque UL/CSA | 7.08 in·lb |
| Pilot Duty UL/CSA | B300 |
| Flammability According to UL94 | V-0 |
| Environmental | |
| Ambient Air Temperature | Operation -25 ... +60 °C |
| Storage -40 ... +85 °C | |
| Maximum Operating Altitude Permissible | Without Derating 2000 m |
| Material Compliance | |
| Conflict Minerals Reporting Template (CMRT) | 9AKK108467A5658 |
| REACH Declaration | 1SVD981001-4501 |
| RoHS Declaration | 1SVD981001-4401 |
| Simplified SCIP | 0c4addbb-9ba9-4814-953e-ae9af6b12914 Sweden |
| 0e87a012-1ca0-45cd-972e-75921cd7d098 Germany | |
| 161b985f-0553-4057-b018-fefa48dc724b Denmark | |
| 436a4aa7-35cc-4f8e-977d-4245db4d730b Portugal | |
| 4e84945e-c3f1-4fa5-9a99-29aae9df0dd2 Czech Republic | |
| 6041161d-7e59-44f4-b0db-dbca463f3e98 Croatia | |
| 7aa39188-e15b-4e08-a340-acb8d151f7a3 Estonia | |
| 894afd0b-31d0-4c5c-bf37-e16e372cab4d Norway | |
| 97d90a47-ca29-4071-9e8c-2e650d0b0e35 Netherlands | |
| 9aedb86b-3497-4a09-9898-36e4eee3e302 Belgium | |
| afbbb6e7-1a7b-4f16-a6a3-87aeb55e194d Poland | |
| c3f4aee4-4fd0-475d-b931-baf08ddefdd1 Bulgaria | |
| d0e7a6eb-4a58-42c7-b04a-c5c207014809 Hungary | |
| d4059696-930e-4070-ab56-2f6c13275ffe Spain | |
| d93c5d3d-805c-4540-9e1a-4d15769f7982 Italy | |
| e3655b77-45d6-45b4-8775-3853d17dcd27 France | |
| eaa459e9-9fb9-4bfe-864f-fc110e192084 Greece | |
| f5b2b1dd-aad6-419a-b1a1-a9744e64d2df Finland | |
| Toxic Substances Control Act - TSCA | 2CMT2023-006536 |
| ABB EcoSolutions | |
| ABB EcoSolutions | Yes |
| Environmental Product Declaration - EPD | 1SAC200438H0001 |
| Certificates and Declarations | |
| ATEX Certificate | EU Type Examination Certificate_TPS_18_ATEX_044254_0018_X |
| CB Certificate | CB_DK-40837-UL |
| CCC Certificate | CCC_2005010303165479 |
| CQC Certificate | CQC2005010303165479 |
| cULus Certificate | cULus508_20140912-E140448 |
| Declaration of Conformity - CCC | 2020980303000194 |
| Declaration of Conformity - CE | 1SVD981007 |
| Declaration of Conformity - UKCA | 1SVD981007-10 |
| DNV GL Certificate | DNVGL_TAE00003W4 |
| Container Information | |
| Package Level 1 Units | box 1 piece |
| Package Level 1 Width | 97 mm |
| Package Level 1 Depth / Length | 30 mm |
| Package Level 1 Height | 109 mm |
| Package Level 1 Gross Weight | 0.153 kg |
| Package Level 1 EAN | 4013614496622 |
| External Classifications and Standards | |
| Object Classification Code | B |
| ETIM 7 | EC002568 - Relay for thermistor protection (PTC) |
| ETIM 8 | EC002568 - Relay for thermistor protection (PTC) |
| ETIM 9 | EC002568 - Relay for thermistor protection (PTC) |
| eClass | V11.0 : 27371503 |
| UNSPSC | 39122331 |
| E-Number (Finland) | 2712399 |
| E-Number (Norway) | 4187716 |
| E-Number (Sweden) | 3860722 |