ABB 1SVR740700R2100 1SVR740700R2100 ABB CM-MSS.13P Therm. motor protec. relay 1c/o, 110-130VAC/220-240VAC View larger
Images are for illustrative purposes only. Please refer to data sheet for details

1SVR740700R2100 ABB CM-MSS.13P Therm. motor protec. relay 1c/o, 110-130VAC/220-240VAC

1SVR740700R2100

740700

ABB

1 Pcs.

CM-MSS.13P Therm. motor protec. relay 1c/o, 110-130VAC/220-240VAC CM-MSS.13P MOTOR CONTROL RELAY x PTC

Automation > Relay for thermistor protection (PTC)
Monitoring

Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.

Request a Quote

Pricing and availability are confirmed for each enquiry. Add your required quantity to begin.

No account, online checkout or payment is required.

More info

Ordering
EAN4013614496592
Minimum Order Quantity1 piece
Customs Tariff Number85364900
Popular Downloads
Data Sheet, Technical Information2CDC112219D0201
Instructions and Manuals1SVC730700M1000
1SVC730700M0000
CAD Dimensional Drawing2CDC001079B0201
EPLAN Data9AAC132589_EPLAN
Dimensions
Product Net Width22.5 mm
Product Net Height85.6 mm
Product Net Depth / Length103.7 mm
Product Net Weight0.147 kg
Technical
Function1 sensor circuit
Auto reset
Rated Control Supply Voltage (Us)110 ... 130 V AC
220 ... 240 V AC
Rated Operational VoltageAuxiliary Circuit 250 V AC
Rated Frequency (f)Supply Circuit 50/60 Hz
Output1 C/O (SPDT) Contact
Terminal TypeScrewless Terminals
Rated Operational Current AC-12 (Ie)(230 V) 4 A
Rated Operational Current AC-15 (Ie)(230 V) 3 A
Rated Operational Current DC-12 (Ie)(24 V) 4 A
Rated Operational Current DC-13 (Ie)(24 V) 2 A
Minimum Switching Capacity24 V
10 mA
Rated Impulse Withstand Voltage (Uimp)Output Circuit 1 / Output Circuit 2 4 kV
Output Circuit 4 kV
Rated Insulation Voltage (Ui)Measuring Circuit / Output Circuit 300 V
Output Circuit 1 / Output Circuit 2 300 V
Supply Circuit / Measuring Circuit 300 V
Supply Circuit / Output Circuit 300 V
Degree of ProtectionHousing IP50
Terminals IP20
Overvoltage CategoryIII
Pollution Degree3
Short-Circuit Protective DevicesOutput Circuit NC - F Type Fuses 6 A
Output Circuit NO - F Type Fuses 10 A
Electrical DurabilityAC-12 100000 cycle
Mechanical DurabilityNr. Operations 30000000 cycle
Connecting CapacityFlexible 2x 0.5 ... 1.5 mm²
Rigid 2x 0.5 ... 1.5 mm²
Tightening TorqueAuxiliary Circuit 1 ... 1.2 N·m
Main Circuit 2.5 ... 2.7 N·m
Wire Stripping Length8 mm
Auxiliary Circuit 9 mm
Main Circuit 12 mm
Mounting Position1 ... 6
Mounting on DIN RailTH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715
TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
StandardsCAN/CSA C22.2 No.14
IEC/EN 63000
IEC/EN 60947-5-1
IEC/EN 60947-8
UL 508
Technical UL/CSA
Maximum Operating Voltage UL/CSAOutput Circuit 300 V AC
Contact Rating UL/CSA(NC:) Q600
(NO:) Q600
(NC:) B600
(NO:) D300
B300
Connecting Capacity UL/CSAFlexible 2x 18-16 AWG
Rigid 2x 20-16 AWG
Connecting Capacity Main Circuit UL/CSAFlexible 1/2x 18-10 AWG
Connecting Capacity Auxiliary Circuit UL/CSAFlexible 1/2x 18-12 AWG
Pilot Duty UL/CSAB300
NC B600
NC Q600
NO D300
NO Q600
Flammability According to UL94V-0
Environmental
Ambient Air TemperatureOperation -25 ... +60 °C
Storage -40 ... +85 °C
Maximum Operating Altitude PermissibleWithout Derating 2000 m
Material Compliance
Conflict Minerals Reporting Template (CMRT)9AKK108467A5658
REACH Declaration1SVD981001-4501
RoHS Declaration1SVD981001-4401
SCIP38f8a198-1a14-4779-b53a-df33c8088756 Germany
Simplified SCIP9bfab677-4ed6-43a0-ab35-b006116ac8f0 Poland
6316a0b2-d106-4194-aa9d-bfd99b2e57c5 Italy
4b518675-566d-4928-950a-5671480ff608 Germany
64ba0bff-cabb-45fc-9382-09ad1a965592 Netherlands
1816ec0f-e136-4665-8504-bc0bf78a7e32 Croatia
80ce10f6-f681-46c4-b542-0af66d564814 Greece
38e86b46-5463-4659-8e28-4a5cde8ade3d Norway
99854c0f-0b01-4fc8-ba34-9d1e333decb8 Portugal
b6e0919e-43e9-4dfd-950b-ec2a97b91b0a France
d0923066-f426-4914-8e7b-4822fb48478c Sweden
876fbccb-e3dd-4a10-92bf-729ae60471ef Hungary
f8fca71a-ef39-4ebf-bc67-6f8d1fc2d1f2 Belgium
171c5c64-2b8b-4f07-88f3-56b686cc6f77 Estonia
d924a6d2-7b74-4bc1-aced-067158bd82e9 Sweden
584b69c8-481f-4310-a17b-907f8d2e1381 Hungary
c252d4fe-a174-4880-9aad-1a55224d15a7 Spain
d31a3c39-eaae-4bf5-bc11-f1366db633d4 Bulgaria
3d136e20-e230-41f0-bab0-75b546a8203e Belgium
eff3db09-2a4d-4a06-bbf8-c3bfad4b2d88 Germany
95db3e5d-dd12-4e00-96d5-093fa3e0058a France
e1df7cdb-079c-48bb-8ca7-8343cff89aa4 Poland
2100883d-5881-43bf-9481-d56ce1910017 Czech Republic
a122c546-4844-44a8-8630-44ae0ca7b638 Germany
7839ba58-22ca-4230-9ac5-d8bc4f618b7b Denmark
2f0cee45-4c56-4767-8d0d-2d14ecf04268 Poland
e6e84213-8b7c-43e1-bf32-250dbbad466b Finland
b778d9a9-4c8e-4f39-9f74-7014c5a43975 Germany
Toxic Substances Control Act - TSCA2CMT2023-006536
ABB EcoSolutions
Environmental Product Declaration - EPD1SAC200438H0001
Certificates and Declarations
CB CertificateCB_DK-40837-UL
CCC CertificateCCC_2005010303165479
CQC CertificateCQC2005010303165479
cULus CertificatecULus508_20140912-E140448
Declaration of Conformity - CCC2020980303000194
Declaration of Conformity - CE1SVD981006
Declaration of Conformity - UKCA1SVD981006-10
DNV GL CertificateDNVGL_TAE00003W4
Container Information
Package Level 1 Unitsbox 1 piece
Package Level 1 Width97 mm
Package Level 1 Depth / Length30 mm
Package Level 1 Height109 mm
Package Level 1 Gross Weight0.171 kg
Package Level 1 EAN4013614496592
External Classifications and Standards
Object Classification CodeB
ETIM 7EC002568 - Relay for thermistor protection (PTC)
ETIM 8EC002568 - Relay for thermistor protection (PTC)
ETIM 9EC002568 - Relay for thermistor protection (PTC)
eClassV11.0 : 27371503
UNSPSC39122331
E-Number (Finland)2712396
E-Number (Norway)4188165
E-Number (Sweden)3860715

Product Datasheet

Electrica Online Product Datasheet Prepared from the current product description, catalog data and structured technical attributes.