1SVR740700R2100 ABB CM-MSS.13P Therm. motor protec. relay 1c/o, 110-130VAC/220-240VAC
1SVR740700R2100
740700
ABB
1 Pcs.
Automation > Relay for thermistor protection (PTC)
Monitoring
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
This ABB 1SVR740700R2100 CM-MSS.13P thermistor motor protection relay provides critical thermal monitoring for industrial drives and rotating equipment. Standard relays in this category protect against thermal overload by tripping motor contactors when sensor resistance indicates excessive heat buildup. Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- EAN: 4013614496592
- Minimum Order Quantity: 1 piece
- Customs Tariff Number: 85364900
- Data Sheet, Technical Information: 2CDC112219D0201
- Instructions and Manuals: 1SVC730700M1000
- CAD Dimensional Drawing: 2CDC001079B0201
- EPLAN Data: 9AAC132589_EPLAN
- Product Net Width: 22.5 mm
- Product Net Height: 85.6 mm
- Product Net Depth / Length: 103.7 mm
- Product Net Weight: 0.147 kg
- Function: 1 sensor circuit
- Rated Control Supply Voltage (U s ): 110 ... 130 V AC
- Rated Operational Voltage: Auxiliary Circuit 250 V AC
- Rated Frequency (f): Supply Circuit 50/60 Hz
- Output: 1 C/O (SPDT) Contact
More info
▲| Ordering | |
|---|---|
| EAN | 4013614496592 |
| Minimum Order Quantity | 1 piece |
| Customs Tariff Number | 85364900 |
| Popular Downloads | |
| Data Sheet, Technical Information | 2CDC112219D0201 |
| Instructions and Manuals | 1SVC730700M1000 |
| 1SVC730700M0000 | |
| CAD Dimensional Drawing | 2CDC001079B0201 |
| EPLAN Data | 9AAC132589_EPLAN |
| Dimensions | |
| Product Net Width | 22.5 mm |
| Product Net Height | 85.6 mm |
| Product Net Depth / Length | 103.7 mm |
| Product Net Weight | 0.147 kg |
| Technical | |
| Function | 1 sensor circuit |
| Auto reset | |
| Rated Control Supply Voltage (Us) | 110 ... 130 V AC |
| 220 ... 240 V AC | |
| Rated Operational Voltage | Auxiliary Circuit 250 V AC |
| Rated Frequency (f) | Supply Circuit 50/60 Hz |
| Output | 1 C/O (SPDT) Contact |
| Terminal Type | Screwless Terminals |
| Rated Operational Current AC-12 (Ie) | (230 V) 4 A |
| Rated Operational Current AC-15 (Ie) | (230 V) 3 A |
| Rated Operational Current DC-12 (Ie) | (24 V) 4 A |
| Rated Operational Current DC-13 (Ie) | (24 V) 2 A |
| Minimum Switching Capacity | 24 V |
| 10 mA | |
| Rated Impulse Withstand Voltage (Uimp) | Output Circuit 1 / Output Circuit 2 4 kV |
| Output Circuit 4 kV | |
| Rated Insulation Voltage (Ui) | Measuring Circuit / Output Circuit 300 V |
| Output Circuit 1 / Output Circuit 2 300 V | |
| Supply Circuit / Measuring Circuit 300 V | |
| Supply Circuit / Output Circuit 300 V | |
| Degree of Protection | Housing IP50 |
| Terminals IP20 | |
| Overvoltage Category | III |
| Pollution Degree | 3 |
| Short-Circuit Protective Devices | Output Circuit NC - F Type Fuses 6 A |
| Output Circuit NO - F Type Fuses 10 A | |
| Electrical Durability | AC-12 100000 cycle |
| Mechanical Durability | Nr. Operations 30000000 cycle |
| Connecting Capacity | Flexible 2x 0.5 ... 1.5 mm² |
| Rigid 2x 0.5 ... 1.5 mm² | |
| Tightening Torque | Auxiliary Circuit 1 ... 1.2 N·m |
| Main Circuit 2.5 ... 2.7 N·m | |
| Wire Stripping Length | 8 mm |
| Auxiliary Circuit 9 mm | |
| Main Circuit 12 mm | |
| Mounting Position | 1 ... 6 |
| Mounting on DIN Rail | TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715 |
| TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715 | |
| Standards | CAN/CSA C22.2 No.14 |
| IEC/EN 63000 | |
| IEC/EN 60947-5-1 | |
| IEC/EN 60947-8 | |
| UL 508 | |
| Technical UL/CSA | |
| Maximum Operating Voltage UL/CSA | Output Circuit 300 V AC |
| Contact Rating UL/CSA | (NC:) Q600 |
| (NO:) Q600 | |
| (NC:) B600 | |
| (NO:) D300 | |
| B300 | |
| Connecting Capacity UL/CSA | Flexible 2x 18-16 AWG |
| Rigid 2x 20-16 AWG | |
| Connecting Capacity Main Circuit UL/CSA | Flexible 1/2x 18-10 AWG |
| Connecting Capacity Auxiliary Circuit UL/CSA | Flexible 1/2x 18-12 AWG |
| Pilot Duty UL/CSA | B300 |
| NC B600 | |
| NC Q600 | |
| NO D300 | |
| NO Q600 | |
| Flammability According to UL94 | V-0 |
| Environmental | |
| Ambient Air Temperature | Operation -25 ... +60 °C |
| Storage -40 ... +85 °C | |
| Maximum Operating Altitude Permissible | Without Derating 2000 m |
| Material Compliance | |
| Conflict Minerals Reporting Template (CMRT) | 9AKK108467A5658 |
| REACH Declaration | 1SVD981001-4501 |
| RoHS Declaration | 1SVD981001-4401 |
| SCIP | 38f8a198-1a14-4779-b53a-df33c8088756 Germany |
| Simplified SCIP | 9bfab677-4ed6-43a0-ab35-b006116ac8f0 Poland |
| 6316a0b2-d106-4194-aa9d-bfd99b2e57c5 Italy | |
| 4b518675-566d-4928-950a-5671480ff608 Germany | |
| 64ba0bff-cabb-45fc-9382-09ad1a965592 Netherlands | |
| 1816ec0f-e136-4665-8504-bc0bf78a7e32 Croatia | |
| 80ce10f6-f681-46c4-b542-0af66d564814 Greece | |
| 38e86b46-5463-4659-8e28-4a5cde8ade3d Norway | |
| 99854c0f-0b01-4fc8-ba34-9d1e333decb8 Portugal | |
| b6e0919e-43e9-4dfd-950b-ec2a97b91b0a France | |
| d0923066-f426-4914-8e7b-4822fb48478c Sweden | |
| 876fbccb-e3dd-4a10-92bf-729ae60471ef Hungary | |
| f8fca71a-ef39-4ebf-bc67-6f8d1fc2d1f2 Belgium | |
| 171c5c64-2b8b-4f07-88f3-56b686cc6f77 Estonia | |
| d924a6d2-7b74-4bc1-aced-067158bd82e9 Sweden | |
| 584b69c8-481f-4310-a17b-907f8d2e1381 Hungary | |
| c252d4fe-a174-4880-9aad-1a55224d15a7 Spain | |
| d31a3c39-eaae-4bf5-bc11-f1366db633d4 Bulgaria | |
| 3d136e20-e230-41f0-bab0-75b546a8203e Belgium | |
| eff3db09-2a4d-4a06-bbf8-c3bfad4b2d88 Germany | |
| 95db3e5d-dd12-4e00-96d5-093fa3e0058a France | |
| e1df7cdb-079c-48bb-8ca7-8343cff89aa4 Poland | |
| 2100883d-5881-43bf-9481-d56ce1910017 Czech Republic | |
| a122c546-4844-44a8-8630-44ae0ca7b638 Germany | |
| 7839ba58-22ca-4230-9ac5-d8bc4f618b7b Denmark | |
| 2f0cee45-4c56-4767-8d0d-2d14ecf04268 Poland | |
| e6e84213-8b7c-43e1-bf32-250dbbad466b Finland | |
| b778d9a9-4c8e-4f39-9f74-7014c5a43975 Germany | |
| Toxic Substances Control Act - TSCA | 2CMT2023-006536 |
| ABB EcoSolutions | |
| Environmental Product Declaration - EPD | 1SAC200438H0001 |
| Certificates and Declarations | |
| CB Certificate | CB_DK-40837-UL |
| CCC Certificate | CCC_2005010303165479 |
| CQC Certificate | CQC2005010303165479 |
| cULus Certificate | cULus508_20140912-E140448 |
| Declaration of Conformity - CCC | 2020980303000194 |
| Declaration of Conformity - CE | 1SVD981006 |
| Declaration of Conformity - UKCA | 1SVD981006-10 |
| DNV GL Certificate | DNVGL_TAE00003W4 |
| Container Information | |
| Package Level 1 Units | box 1 piece |
| Package Level 1 Width | 97 mm |
| Package Level 1 Depth / Length | 30 mm |
| Package Level 1 Height | 109 mm |
| Package Level 1 Gross Weight | 0.171 kg |
| Package Level 1 EAN | 4013614496592 |
| External Classifications and Standards | |
| Object Classification Code | B |
| ETIM 7 | EC002568 - Relay for thermistor protection (PTC) |
| ETIM 8 | EC002568 - Relay for thermistor protection (PTC) |
| ETIM 9 | EC002568 - Relay for thermistor protection (PTC) |
| eClass | V11.0 : 27371503 |
| UNSPSC | 39122331 |
| E-Number (Finland) | 2712396 |
| E-Number (Norway) | 4188165 |
| E-Number (Sweden) | 3860715 |