View larger
1SVR740720R1400 ABB CM-MSS.11P Therm. motor protec. relay 1n/o+1n/c, 24-240VAC/DC
1SVR740720R1400
740720
ABB
1 Pcs.
Automation > Relay for thermistor protection (PTC)
Monitoring
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
Continuous thermal surveillance of industrial drives is managed efficiently by an Abb CM-MSS.11P therm. motor protec. relay 1n/o+1n/c, 24-240VAC/DC. These protective relays disconnect control circuits upon detecting excessive heat, preventing premature motor failure across automated manufacturing systems.
Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- EAN: 4013614496523
- Minimum Order Quantity: 1 piece
- Customs Tariff Number: 85364900
- Data Sheet, Technical Information: 2CDC112215D0201
- Instructions and Manuals: 1SVC730700M1000
- Ex Operating Instructions: 1SVC730640M9000
- CAD Dimensional Drawing: 2CDC001079B0201
- EPLAN Data: 9AAC132589_EPLAN
- Product Net Width: 22.5 mm
- Product Net Height: 85.6 mm
- Product Net Depth / Length: 103.7 mm
- Product Net Weight: 0.119 kg
- Function: 1 sensor circuit
- Rated Control Supply Voltage (U s ): 24 ... 240 V AC/DC
- Rated Operational Voltage: Auxiliary Circuit 250 V AC
- Rated Frequency (f): Supply Circuit 15 ... 400 Hz
More info
▲| Ordering | |
|---|---|
| EAN | 4013614496523 |
| Minimum Order Quantity | 1 piece |
| Customs Tariff Number | 85364900 |
| Popular Downloads | |
| Data Sheet, Technical Information | 2CDC112215D0201 |
| Instructions and Manuals | 1SVC730700M1000 |
| 1SVC730700M0000 | |
| Ex Operating Instructions | 1SVC730640M9000 |
| CAD Dimensional Drawing | 2CDC001079B0201 |
| EPLAN Data | 9AAC132589_EPLAN |
| Dimensions | |
| Product Net Width | 22.5 mm |
| Product Net Height | 85.6 mm |
| Product Net Depth / Length | 103.7 mm |
| Product Net Weight | 0.119 kg |
| Technical | |
| Function | 1 sensor circuit |
| Non-volatile fault storage | |
| Dynamic interrupted wire detection | |
| Auto reset | |
| ATEX approved | |
| Rated Control Supply Voltage (Us) | 24 ... 240 V AC/DC |
| Rated Operational Voltage | Auxiliary Circuit 250 V AC |
| Rated Frequency (f) | Supply Circuit 15 ... 400 Hz |
| Output | 1 N/O, 1 N/C Contact |
| Terminal Type | Screwless Terminals |
| Rated Operational Current AC-12 (Ie) | (230 V) 4 A |
| Rated Operational Current AC-15 (Ie) | (230 V) 3 A |
| Rated Operational Current DC-12 (Ie) | (24 V) 4 A |
| Rated Operational Current DC-13 (Ie) | (24 V) 2 A |
| Minimum Switching Capacity | 24 V |
| 10 mA | |
| Rated Impulse Withstand Voltage (Uimp) | Output Circuit 1 / Output Circuit 2 4 kV |
| Output Circuit 4 kV | |
| Rated Insulation Voltage (Ui) | Measuring Circuit / Output Circuit 300 V |
| Output Circuit 1 / Output Circuit 2 300 V | |
| Supply Circuit / Measuring Circuit 300 V | |
| Supply Circuit / Output Circuit 300 V | |
| Degree of Protection | Housing IP50 |
| Terminals IP20 | |
| Overvoltage Category | III |
| Pollution Degree | 3 |
| Short-Circuit Protective Devices | Output Circuit NC - F Type Fuses 10 A |
| Output Circuit NO - F Type Fuses 10 A | |
| Electrical Durability | AC-12 100000 cycle |
| Mechanical Durability | Nr. Operations 30000000 cycle |
| Connecting Capacity | Flexible 2x 0.5 ... 1.5 mm² |
| Rigid 2x 0.5 ... 1.5 mm² | |
| Tightening Torque | Auxiliary Circuit 1 ... 1.2 N·m |
| Main Circuit 2.5 ... 2.7 N·m | |
| Wire Stripping Length | 8 mm |
| Auxiliary Circuit 9 mm | |
| Main Circuit 12 mm | |
| Mounting Position | 1 ... 6 |
| Mounting on DIN Rail | TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715 |
| TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715 | |
| Standards | CAN/CSA C22.2 No.14 |
| EN 50495 | |
| IEC/EN 63000 | |
| IEC/EN 60079-7 | |
| IEC/EN 60947-5-1 | |
| IEC/EN 60947-8 | |
| UL 508 | |
| Technical UL/CSA | |
| Maximum Operating Voltage UL/CSA | Output Circuit 300 V AC |
| Contact Rating UL/CSA | (NC:) Q600 |
| (NO:) Q600 | |
| (NC:) B600 | |
| (NO:) D300 | |
| B300 | |
| Connecting Capacity UL/CSA | Flexible 2x 18-16 AWG |
| Rigid 2x 20-16 AWG | |
| Connecting Capacity Main Circuit UL/CSA | Flexible 1/2x 14-6 AWG |
| Connecting Capacity Auxiliary Circuit UL/CSA | Flexible 1/2x 18-12 AWG |
| Pilot Duty UL/CSA | B300 |
| NC B600 | |
| NC Q600 | |
| NO D300 | |
| NO Q600 | |
| Flammability According to UL94 | V-0 |
| Environmental | |
| Ambient Air Temperature | Operation -25 ... +60 °C |
| Storage -40 ... +85 °C | |
| Maximum Operating Altitude Permissible | Without Derating 2000 m |
| Material Compliance | |
| Conflict Minerals Reporting Template (CMRT) | 9AKK108467A5658 |
| REACH Declaration | 1SVD981001-4501 |
| RoHS Declaration | 1SVD981001-4401 |
| SCIP | bc71a421-14b0-40eb-9b12-f5d916f2bcef Germany |
| Simplified SCIP | 06a223d3-0be0-4448-98bf-dda2fb200cac Norway |
| 0c8a3fbf-a51f-45e4-b0e4-0cf9fc767384 Estonia | |
| 111bc2d2-3190-4861-90d8-292a99151327 Finland | |
| 18fd6bb7-07d2-46af-8ef6-6b9e63539dd7 Sweden | |
| 191555c3-aaa1-4939-90a2-73822945dd9b Portugal | |
| 1f48e209-9122-40e3-96bc-a43e9032b472 Italy | |
| 28b046cc-a28b-4db8-acd0-8e40da8828d2 Belgium | |
| 2e781c79-8f42-4e23-bd15-e24af75a7a96 Spain | |
| 2f01e3a3-59dd-4ef8-913f-6fac998231ce Germany | |
| 447d53d1-eeb0-4394-be6c-4f1d5e1a47a5 France | |
| 5e46db6b-98c0-4151-a4d5-279458ec96eb Belgium | |
| 626bb25f-1a2f-4ef5-9d11-610859e5c5d4 Germany | |
| 8291d2e5-feff-4c7f-b995-357518671d11 Germany | |
| 907a73c2-6233-4df6-8ce9-073ddcb8137d Denmark | |
| 91b16b3e-c372-4517-80fa-c5ac39a25337 Czech Republic | |
| 979e7b37-28ee-4b8d-968e-2c6eb8479f3f Germany | |
| 9b7c39c3-456f-4bfe-b981-99c2dc6d830d Netherlands | |
| b0b9d70f-c97a-4638-9753-a1cb7bde32d1 Sweden | |
| b88b5a38-5ef7-4432-98d6-eaa7504a1c02 Poland | |
| cb11a210-2ce8-457d-aa2f-53e56fda6d7a Bulgaria | |
| d2031e16-aab4-4b47-bd4d-e12baf752b3f France | |
| d9b6411a-737e-44ca-9ff4-383b5a8ec40d Greece | |
| da521cd9-823f-4167-8b49-b7db9ec74426 Hungary | |
| df81d6a2-35b0-4188-9b1b-dfefc699f4d4 Hungary | |
| e4f60d18-4cb5-42a6-a754-e67d8505dabf Poland | |
| f6f090af-a8af-4eb8-8bc2-ee225d78c352 Poland | |
| ff8a9a0c-0535-48c6-9645-2974280550ff Croatia | |
| Toxic Substances Control Act - TSCA | 2CMT2023-006536 |
| ABB EcoSolutions | |
| Environmental Product Declaration - EPD | 1SAC200438H0001 |
| Certificates and Declarations | |
| ATEX Certificate | EU Type Examination Certificate_TPS_18_ATEX_044254_0018_X |
| CB Certificate | CB_DK-40837-UL |
| CCC Certificate | CCC_2005010303165479 |
| CQC Certificate | CQC2005010303165479 |
| cULus Certificate | cULus508_20140912-E140448 |
| Declaration of Conformity - CCC | 2020980303000194 |
| Declaration of Conformity - CE | 1SVD981007 |
| Declaration of Conformity - UKCA | 1SVD981007-10 |
| DNV GL Certificate | DNVGL_TAE00003W4 |
| Container Information | |
| Package Level 1 Units | box 1 piece |
| Package Level 1 Width | 97 mm |
| Package Level 1 Depth / Length | 30 mm |
| Package Level 1 Height | 109 mm |
| Package Level 1 Gross Weight | 0.146 kg |
| Package Level 1 EAN | 4013614496523 |
| External Classifications and Standards | |
| Object Classification Code | B |
| ETIM 7 | EC002568 - Relay for thermistor protection (PTC) |
| ETIM 8 | EC002568 - Relay for thermistor protection (PTC) |
| ETIM 9 | EC002568 - Relay for thermistor protection (PTC) |
| eClass | V11.0 : 27371503 |
| UNSPSC | 39122331 |
| E-Number (Finland) | 2712393 |
| E-Number (Norway) | 4188184 |
| E-Number (Sweden) | 3860711 |