View larger
1SVR730884R4300 ABB CM-MPS.43S Three-phase monitoring relay 2c/o, 0,0.1-30s, L1-L2-L3 3x300-500VAC
1SVR730884R4300
730884
ABB
1 Pcs.
Automation > Phase monitoring relay
Monitoring
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
Three-phase monitoring relay model 1SVR730884R4300 from Abb protects industrial electrical networks by continuously checking for phase failures, incorrect phase sequences, and voltage fluctuations. These protective devices are widely installed in control panels to prevent motor damage and operational downtime caused by unstable power supplies. Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- EAN: 4016779851879
- Minimum Order Quantity: 1 piece
- Customs Tariff Number: 85364900
- Data Sheet, Technical Information: 2CDC112204D0201
- Instructions and Manuals: 1SVC730730M1000
- CAD Dimensional Drawing: 2CDC001079B0201
- EPLAN Data: 9AAC132608_EPLAN
- Product Net Width: 22.5 mm
- Product Net Height: 85.6 mm
- Product Net Depth / Length: 103.7 mm
- Product Net Weight: 0.148 kg
- Function: Automatic phase sequence correction
- Measuring Range: (L-L) 300 ... 500 V AC
- Time Range: Tripping Delay (ON or OFF) 0 second [unit of time]
- Rated Control Supply Voltage (U s ): (L-L) 300 ... 500 V AC
- Rated Frequency (f): Supply Circuit 50/60/400 Hz
More info
▲| Ordering | |
|---|---|
| EAN | 4016779851879 |
| Minimum Order Quantity | 1 piece |
| Customs Tariff Number | 85364900 |
| Popular Downloads | |
| Data Sheet, Technical Information | 2CDC112204D0201 |
| Instructions and Manuals | 1SVC730730M1000 |
| 1SVC730730M0000 | |
| CAD Dimensional Drawing | 2CDC001079B0201 |
| EPLAN Data | 9AAC132608_EPLAN |
| Dimensions | |
| Product Net Width | 22.5 mm |
| Product Net Height | 85.6 mm |
| Product Net Depth / Length | 103.7 mm |
| Product Net Weight | 0.148 kg |
| Technical | |
| Function | Automatic phase sequence correction |
| Over- and undervoltage monitoring | |
| Phase failure detection | |
| Phase unbalance detection | |
| Phase sequence monitoring | |
| Measuring Range | (L-L) 300 ... 500 V AC |
| Time Range | Tripping Delay (ON or OFF) 0 second [unit of time] |
| Rated Control Supply Voltage (Us) | (L-L) 300 ... 500 V AC |
| Rated Frequency (f) | Supply Circuit 50/60/400 Hz |
| Output | 2 x 1 c/o or 1 x 2 c/o contacts, configurable |
| Terminal Type | Screw Terminals |
| Rated Operational Current AC-12 (Ie) | (230 V) 4 A |
| Rated Operational Current AC-15 (Ie) | (230 V) 3 A |
| Rated Operational Current DC-12 (Ie) | (24 V) 4 A |
| Rated Operational Current DC-13 (Ie) | (24 V) 2 A |
| Minimum Switching Capacity | 24 V |
| 10 mA | |
| Rated Impulse Withstand Voltage (Uimp) | Input Circuit 6 kV |
| Output Circuit 4 kV | |
| Rated Insulation Voltage (Ui) | Input Circuit / Output Circuit 600 V |
| Output Circuit 1 / Output Circuit 2 300 V | |
| Degree of Protection | Housing IP50 |
| Terminals IP20 | |
| Overvoltage Category | III |
| Pollution Degree | 3 |
| Short-Circuit Protective Devices | Output Circuit NC - F Type Fuses 6 A |
| Output Circuit NO - F Type Fuses 10 A | |
| Electrical Durability | AC-12 100000 cycle |
| Mechanical Durability | Nr. Operations 30000000 cycle |
| Connecting Capacity | Flexible with Ferrule 1x 0.5 ... 2.5 mm² |
| Flexible with Ferrule 2x 0.5 ... 1.5 mm² | |
| Flexible with Insulated Ferrule 1x 0.5 ... 2.5 mm² | |
| Flexible with Insulated Ferrule 2x 0.5 ... 1.5 mm² | |
| Flexible 1x 0.5 ... 2.5 mm² | |
| Flexible 2x 0.5 ... 1.5 mm² | |
| Rigid 1x 0.5 ... 4 mm² | |
| Rigid 2x 0.5 ... 2.5 mm² | |
| Tightening Torque | 0.6 ... 0.8 N·m |
| Wire Stripping Length | 8 mm |
| Recommended Screw Driver | 4.5 |
| 0.8 x 4 | |
| Pozidriv 1 | |
| Mounting Position | 1 ... 6 |
| Mounting on DIN Rail | TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715 |
| TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715 | |
| Standards | CAN/CSA C22.2 No.14 |
| IEC/EN 63000 | |
| IEC/EN 60255-27 | |
| IEC/EN 61000-6-2 | |
| IEC/EN 61000-6-3 | |
| UL 508 | |
| Technical UL/CSA | |
| Maximum Operating Voltage UL/CSA | Output Circuit 300 V AC |
| Contact Rating UL/CSA | B300 |
| Connecting Capacity UL/CSA | Flexible 1x 18-14 AWG |
| Flexible 2x 18-16 AWG | |
| Rigid 2x 20-14 AWG | |
| Rigid 1x 20-12 AWG | |
| Tightening Torque UL/CSA | 7.08 in·lb |
| Pilot Duty UL/CSA | B300 |
| Flammability According to UL94 | V-0 |
| Environmental | |
| Ambient Air Temperature | Operation -25 ... +60 °C |
| Storage -40 ... +85 °C | |
| Maximum Operating Altitude Permissible | Without Derating 2000 m |
| Material Compliance | |
| Conflict Minerals Reporting Template (CMRT) | 9AKK108467A5658 |
| REACH Declaration | 1SVD981001-4501 |
| RoHS Declaration | 1SVD981001-4401 |
| SCIP | 391855d7-8ab2-465b-9ea5-5a35944ee08f Germany |
| Simplified SCIP | c1c761b3-5f86-448f-b377-45056579c341 Poland |
| f89f541e-788b-4239-8077-9a0bc10cf30f France | |
| 4bc1d327-7221-49a3-a39a-3b156bb1ef93 Poland | |
| c124575b-33c3-4270-a2a3-561c03fe13ac Denmark | |
| cefb8c06-c2b0-41cd-a042-c5a8041b0edf Finland | |
| 4c577ce9-ed2e-4b00-b62d-c98c4747c820 Norway | |
| 717173b8-84e8-4700-9369-383644542d41 Germany | |
| 69d1d222-265d-46d1-bc55-2c3ef58371cd Belgium | |
| 0e89fa15-ea58-4893-b5bc-c9cd4c3d7f3e Czech Republic | |
| ad7a15bf-7b12-4b1e-9f95-dc7528ec87ce Germany | |
| 43ce8a04-1c7e-41da-ad5b-57494a7de522 Germany | |
| e38e4351-361d-48ef-b776-f25982476bbd Italy | |
| 1da160d6-732b-4299-bf32-5d70eca222ff Croatia | |
| ef3b9a54-a24e-42b7-b34f-a9666ae873e7 Estonia | |
| 11c45022-6809-4495-a367-cec2c2d34afa Poland | |
| 7966180f-cbe4-4093-bfd3-5cb17027ec95 Hungary | |
| 341a71a2-2d38-4747-b7cb-cadfbbd42467 Spain | |
| 5534844a-6443-48e5-aede-18a61a56e558 Hungary | |
| d149c9a3-922b-49de-ba47-8ed0c5297e3a Netherlands | |
| 83f1ede6-6608-4681-93d9-98a444b63153 Greece | |
| dceb739f-178a-411e-94da-5e18e1aa079f Portugal | |
| b6107680-3b40-4cea-a2ba-136c7964c1b0 France | |
| aa0f75dc-18a1-40a5-ab0b-57e07525ff56 Belgium | |
| cb2c3612-9cbb-4827-9a2b-af9213284b43 Germany | |
| d671dcdd-8146-46d3-a13f-967c4c0f3630 Bulgaria | |
| 0b95707a-e3a9-44aa-a9cf-2f3866f5d745 Sweden | |
| cc26bc6e-de09-475c-881a-417544e09994 Sweden | |
| Toxic Substances Control Act - TSCA | 2CMT2023-006536 |
| ABB EcoSolutions | |
| ABB EcoSolutions | Yes |
| Environmental Product Declaration - EPD | 1SAC200438H0001 |
| Certificates and Declarations | |
| CB Certificate | CB_DK-27947-UL |
| CQC Certificate | CQC2009010303326655 |
| cULus Certificate | cULus508_20120829-E140448 |
| Declaration of Conformity - CCC | 2020980303000197 |
| Declaration of Conformity - CE | 1SVD981014-00 |
| Declaration of Conformity - UKCA | 1SVD981014-10 |
| DNV GL Certificate | DNV_GL_TAA000017D |
| Container Information | |
| Package Level 1 Units | box 1 piece |
| Package Level 1 Width | 97 mm |
| Package Level 1 Depth / Length | 30 mm |
| Package Level 1 Height | 109 mm |
| Package Level 1 Gross Weight | 0.173 kg |
| Package Level 1 EAN | 4016779851879 |
| External Classifications and Standards | |
| Object Classification Code | B |
| ETIM 7 | EC001441 - Phase monitoring relay |
| ETIM 8 | EC001441 - Phase monitoring relay |
| ETIM 9 | EC001441 - Phase monitoring relay |
| eClass | V11.0 : 27371803 |
| UNSPSC | 39122332 |
| E-Number (Finland) | 2712280 |
| E-Number (Norway) | 4188140 |
| E-Number (Sweden) | 3860588 |