ABB 1SVR740884R4300 1SVR740884R4300 ABB CM-MPS.43P Three-phase monitoring relay 2c/o, 0,0.1-30s, L1-L2-L3 3x300-500VAC View larger
Images are for illustrative purposes only. Please refer to data sheet for details

1SVR740884R4300 ABB CM-MPS.43P Three-phase monitoring relay 2c/o, 0,0.1-30s, L1-L2-L3 3x300-500VAC

1SVR740884R4300

740884

ABB

1 Pcs.

CM-MPS.43P Three-phase monitoring relay 2c/o, 0,0.1-30s, L1-L2-L3=3x300-500VAC CM-MPS.43P RELe CTRL TRIFaSICO 2 C/C RES

Automation > Phase monitoring relay
Monitoring

Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.

Request a Quote

Pricing and availability are confirmed for each enquiry. Add your required quantity to begin.

No account, online checkout or payment is required.

More info

Ordering
EAN4016779852050
Minimum Order Quantity1 piece
Customs Tariff Number85364900
Popular Downloads
Data Sheet, Technical Information2CDC112204D0201
Instructions and Manuals1SVC730730M1000
1SVC730730M0000
CAD Dimensional Drawing2CDC001079B0201
EPLAN Data9AAC132608_EPLAN
Dimensions
Product Net Width22.5 mm
Product Net Height85.6 mm
Product Net Depth / Length103.7 mm
Product Net Weight0.137 kg
Technical
FunctionAutomatic phase sequence correction
Over- and undervoltage monitoring
Phase failure detection
Phase unbalance detection
Phase sequence monitoring
Measuring Range(L-L) 300 ... 500 V AC
Time RangeTripping Delay (ON or OFF) 0 second [unit of time]
Rated Control Supply Voltage (Us)(L-L) 300 ... 500 V AC
Rated Frequency (f)Supply Circuit 50/60/400 Hz
Output2x 1 C/O or 1x 2 C/O Contact, Configurable
Terminal TypeScrewless Terminals
Rated Operational Current AC-12 (Ie)(230 V) 4 A
Rated Operational Current AC-15 (Ie)(230 V) 3 A
Rated Operational Current DC-12 (Ie)(24 V) 4 A
Rated Operational Current DC-13 (Ie)(24 V) 2 A
Minimum Switching Capacity24 V
10 mA
Rated Impulse Withstand Voltage (Uimp)Input Circuit 6 kV
Output Circuit 4 kV
Rated Insulation Voltage (Ui)Input Circuit / Output Circuit 600 V
Output Circuit 1 / Output Circuit 2 300 V
Degree of ProtectionHousing IP50
Terminals IP20
Overvoltage CategoryIII
Pollution Degree3
Short-Circuit Protective DevicesOutput Circuit NC - F Type Fuses 6 A
Output Circuit NO - F Type Fuses 10 A
Electrical DurabilityAC-12 100000 cycle
Mechanical DurabilityNr. Operations 30000000 cycle
Connecting CapacityFlexible with Ferrule 2x 0.5 ... 1.5 mm²
Flexible with Insulated Ferrule 2x 0.5 ... 1.5 mm²
Flexible 2x 0.5 ... 1.5 mm²
Rigid 2x 0.5 ... 1.5 mm²
Wire Stripping Length8 mm
Mounting Position1 ... 6
Mounting on DIN RailTH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715
StandardsCAN/CSA C22.2 No.14
IEC/EN 63000
IEC/EN 60255-27
IEC/EN 61000-6-2
IEC/EN 61000-6-3
UL 508
Technical UL/CSA
Maximum Operating Voltage UL/CSAOutput Circuit 300 V AC
Contact Rating UL/CSAB300
Connecting Capacity UL/CSAFlexible 2x 18-16 AWG
Rigid 2x 20-16 AWG
Pilot Duty UL/CSAB300
Flammability According to UL94V-0
Environmental
Ambient Air TemperatureOperation -25 ... +60 °C
Storage -40 ... +85 °C
Maximum Operating Altitude PermissibleWithout Derating 2000 m
Material Compliance
Conflict Minerals Reporting Template (CMRT)9AKK108467A5658
REACH Declaration1SVD981001-4501
RoHS Declaration1SVD981001-4401
SCIP276dca46-4db5-437f-a6cb-d33bc9424b5a Germany
Simplified SCIPd2e852d6-b5a8-462a-9c5c-9e0d32c7957c Sweden
e13d0845-dc9c-4483-8b13-927cdd859d9f Italy
f2038fc2-c6f4-43e2-9871-6a39af691341 Germany
a38b1e73-41de-4399-b6e5-efe6ee611b41 Denmark
4c9ea4aa-6d75-422f-9472-32c00db3f1af Germany
0497a200-00e3-4404-9559-b13c22696d35 Croatia
d10acb24-4ce3-48c6-8811-c4cda7c46621 Czech Republic
15d783fd-853a-4377-a9da-fd0e5d74978c Poland
2031c9e7-c740-40c5-ae9e-e24a3ed70fad Netherlands
d8d1ede9-dbbf-419e-bc5c-f1bb9e77e18a Hungary
e2f5193b-be3a-43ff-b318-17ae587daaff Greece
ba61da1c-aab3-4128-a6e6-6583a72f59f6 Portugal
61019568-bc52-4187-8c31-690f2dd73ea6 Belgium
84fb0b82-f866-4e01-9e9d-fc554ee00d9f Bulgaria
dc8a3c3b-8e0e-4961-8a08-bec697adf961 Sweden
b6afcab7-a646-4b48-b4ce-b0bf9cc1cb6f Poland
3eaf3792-929e-4e3a-908a-2ceb51cde5a3 France
4861121c-9cdb-4bf8-b0fd-95c8f511144d Germany
936d7cef-f637-4666-ab59-9bf7f81fb4a7 France
f5c6b191-4608-457a-ab60-f86fa17d239d Hungary
6781e037-c4be-4e4e-b679-97bf13ffb0f5 Spain
1cae1024-63ab-46a2-9eb3-f9bb05cad52d Belgium
7afb33c6-9094-433b-af94-298b7a9ad1fe Norway
97d8e4c4-15ed-418a-8501-eb9352ddfb72 Finland
130116c5-620e-4b5f-9be4-8e21bf445604 Germany
d328d06f-8b08-4d49-9aa7-58f487482bf1 Poland
6843d8e0-3357-4f98-b21e-2ed0ae517731 Estonia
Toxic Substances Control Act - TSCA2CMT2023-006536
ABB EcoSolutions
Environmental Product Declaration - EPD1SAC200438H0001
Certificates and Declarations
CB CertificateCB_DK-27947-UL
CQC CertificateCQC2009010303326655
cULus CertificatecULus508_20120829-E140448
Declaration of Conformity - CCC2020980303000197
Declaration of Conformity - CE1SVD981014-00
Declaration of Conformity - UKCA1SVD981014-10
DNV GL CertificateDNV_GL_TAA000017D
Container Information
Package Level 1 Unitsbox 1 piece
Package Level 1 Width97 mm
Package Level 1 Depth / Length30 mm
Package Level 1 Height109 mm
Package Level 1 Gross Weight0.162 kg
Package Level 1 EAN4016779852050
External Classifications and Standards
Object Classification CodeB
ETIM 7EC001441 - Phase monitoring relay
ETIM 8EC001441 - Phase monitoring relay
ETIM 9EC001441 - Phase monitoring relay
eClassV11.0 : 27371803
UNSPSC39122332
E-Number (Finland)2712279
E-Number (Norway)4188141
E-Number (Sweden)3860607

Product Datasheet

Electrica Online Product Datasheet Prepared from the current product description, catalog data and structured technical attributes.