ABB 1SVR730884R3300 1SVR730884R3300 ABB CM-MPS.41S Three-phase monitoring relay 2c/o, 0,0.1-30s, L1-L2-L3 3x300-500VAC View larger
Images are for illustrative purposes only. Please refer to data sheet for details

1SVR730884R3300 ABB CM-MPS.41S Three-phase monitoring relay 2c/o, 0,0.1-30s, L1-L2-L3 3x300-500VAC

1SVR730884R3300

730884

ABB

1 Pcs.

CM-MPS.41S Three-phase monitoring relay 2c/o, 0,0.1-30s, L1-L2-L3=3x300-500VAC CM-MPS.41S CTRL THREE-PHASE 2 C/C TOR RELAY

Automation > Phase monitoring relay
Monitoring

Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.

Request a Quote

Pricing and availability are confirmed for each enquiry. Add your required quantity to begin.

No account, online checkout or payment is required.

More info

Ordering
EAN4016779851862
Minimum Order Quantity1 piece
Customs Tariff Number85364900
Popular Downloads
Data Sheet, Technical Information2CDC112206D0201
Instructions and Manuals1SVC730730M1000
1SVC730730M0000
CAD Dimensional Drawing2CDC001079B0201
Dimensions
Product Net Width22.5 mm
Product Net Height85.6 mm
Product Net Depth / Length103.7 mm
Product Net Weight0.14 kg
Technical
FunctionPhase failure detection
Phase sequence monitoring
Over- and undervoltage monitoring
Phase unbalance detection
Measuring Range(L-L) 300 ... 500 V AC
Time RangeTripping Delay (ON or OFF) 0 second [unit of time]
Rated Control Supply Voltage (Us)(L-L) 300 ... 500 V AC
Rated Frequency (f)Supply Circuit 50/60 Hz
Output2 C/O Contacts
Terminal TypeScrew Terminals
Rated Operational Current AC-12 (Ie)(230 V) 4 A
Rated Operational Current AC-15 (Ie)(230 V) 3 A
Rated Operational Current DC-12 (Ie)(24 V) 4 A
Rated Operational Current DC-13 (Ie)(24 V) 2 A
Minimum Switching Capacity24 V
10 mA
Rated Impulse Withstand Voltage (Uimp)Input Circuit 6 kV
Output Circuit 4 kV
Rated Insulation Voltage (Ui)Input Circuit / Output Circuit 600 V
Output Circuit 1 / Output Circuit 2 300 V
Degree of ProtectionHousing IP50
Terminals IP20
Overvoltage CategoryIII
Pollution Degree3
Short-Circuit Protective DevicesOutput Circuit NC - F Type Fuses 6 A
Output Circuit NO - F Type Fuses 10 A
Electrical DurabilityAC-12 100000 cycle
Mechanical DurabilityNr. Operations 30000000 cycle
Connecting CapacityFlexible with Ferrule 1x 0.5 ... 2.5 mm²
Flexible with Ferrule 2x 0.5 ... 1.5 mm²
Flexible with Insulated Ferrule 1x 0.5 ... 2.5 mm²
Flexible with Insulated Ferrule 2x 0.5 ... 1.5 mm²
Flexible 1x 0.5 ... 2.5 mm²
Flexible 2x 0.5 ... 1.5 mm²
Rigid 1x 0.5 ... 4 mm²
Rigid 2x 0.5 ... 2.5 mm²
Tightening Torque0.6 ... 0.8 N·m
Wire Stripping Length8 mm
Recommended Screw Driver0.8 x 4
4.5
Pozidriv 1
Mounting Position1 ... 6
Mounting on DIN RailTH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715
TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
StandardsCAN/CSA C22.2 No.14
IEC/EN 63000
IEC/EN 60255-27
IEC/EN 61000-6-2
IEC/EN 61000-6-3
UL 508
Technical UL/CSA
Maximum Operating Voltage UL/CSAOutput Circuit 300 V AC
Contact Rating UL/CSAB300
Connecting Capacity UL/CSAFlexible 1x 18-14 AWG
Flexible 2x 18-16 AWG
Rigid 1x 20-12 AWG
Rigid 2x 20-14 AWG
Tightening Torque UL/CSA7.08 in·lb
Pilot Duty UL/CSAB300
Flammability According to UL94V-0
Environmental
Ambient Air TemperatureOperation -25 ... +60 °C
Storage -40 ... +85 °C
Maximum Operating Altitude PermissibleWithout Derating 2000 m
Material Compliance
Conflict Minerals Reporting Template (CMRT)9AKK108467A5658
REACH Declaration1SVD981001-4501
RoHS Declaration1SVD981001-4401
SCIPdff08fcb-e148-4c63-890c-b8862f1fdf07 Germany
Simplified SCIP07c3b2a7-a357-4c5e-b3a6-f5d953ab698c Finland
a57369f1-8a23-4eb4-821d-c730fe3cc5c8 Germany
33b6e0f5-b11c-481e-b828-0cfe71f0685f Belgium
491c7d74-109d-4946-ab26-4cbce1707d3b Hungary
64d03fe3-9a2a-48dd-b139-b9370fd89e1e Poland
b1e54f61-d37d-4a0e-be10-09c7f9e3312f Denmark
3e9eeda5-4118-4987-a4e7-5d6d15943e62 Germany
0df0a7d1-8e28-4b59-8b92-9b27cef78e31 Czech Republic
92d266cc-80c7-45f7-841e-1473d4b27535 Italy
f6f39749-02d4-4dcf-9591-43af5e9e9583 Germany
4a617c13-9902-4dbf-8c11-7b011f1a5e3c Netherlands
b4c0810d-fbb2-41a3-94f5-c04d41081ea8 Croatia
608b3c32-3059-4bea-9e08-dc60623ecc78 Poland
3ec5e94c-01cb-4d32-9483-ad2af08ce885 Norway
2548762e-991f-470b-9e25-8d8712ac3747 Estonia
b8809dfa-5693-4eae-87cf-7f8f256528c3 Sweden
d6e0b576-1a26-434d-891d-c28ef77141f4 Poland
6d898f99-d342-4deb-89f4-00cc19eafee6 Greece
37a3281e-45af-4397-8a2e-6465a0e4adcb Germany
34432ffb-5036-4202-8f42-db12120ca6bc France
13b6d319-cd48-4abd-84e9-681c5804f43d Belgium
3273c7f8-2e06-4de4-9388-6f16d7f15b5e Hungary
90adfc4f-1803-46a5-800c-ce4953151853 Portugal
3bd28df5-a1be-4406-addb-4c1bcb03a9d3 Spain
93f8a4d6-2ffe-432f-a133-51eb654e438b France
c04ebdff-82c7-4762-b1d4-830bc4d76942 Sweden
f52252ab-bde6-485a-a7aa-4ea9b7bd3dde Bulgaria
Toxic Substances Control Act - TSCA2CMT2023-006536
ABB EcoSolutions
ABB EcoSolutionsYes
Environmental Product Declaration - EPD1SAC200438H0001
Certificates and Declarations
CB CertificateCB_DK-27947-UL
CQC CertificateCQC2009010303326655
cULus CertificatecULus508_20120829-E140448
Declaration of Conformity - CCC2020980303000197
Declaration of Conformity - CE1SVD981014-00
Declaration of Conformity - UKCA1SVD981014-10
DNV GL CertificateDNV_GL_TAA000017D
Container Information
Package Level 1 Unitsbox 1 piece
Package Level 1 Width97 mm
Package Level 1 Depth / Length30 mm
Package Level 1 Height109 mm
Package Level 1 Gross Weight0.165 kg
Package Level 1 EAN4016779851862
External Classifications and Standards
Object Classification CodeB
ETIM 7EC001441 - Phase monitoring relay
ETIM 8EC001441 - Phase monitoring relay
ETIM 9EC001441 - Phase monitoring relay
eClassV11.0 : 27371803
UNSPSC39122332
E-Number (Finland)2712278
E-Number (Norway)4188136
E-Number (Sweden)3860587

Product Datasheet

Electrica Online Product Datasheet Prepared from the current product description, catalog data and structured technical attributes.