View larger
1SVR740884R3300
740884
ABB
1 Pcs.
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
| Ordering | |
|---|---|
| EAN | 4016779852043 |
| Minimum Order Quantity | 1 piece |
| Customs Tariff Number | 85364900 |
| Popular Downloads | |
| Data Sheet, Technical Information | 2CDC112206D0201 |
| Instructions and Manuals | 1SVC730730M1000 |
| 1SVC730730M0000 | |
| CAD Dimensional Drawing | 2CDC001079B0201 |
| EPLAN Data | 9AAC132608_EPLAN |
| Dimensions | |
| Product Net Width | 22.5 mm |
| Product Net Height | 85.6 mm |
| Product Net Depth / Length | 103.7 mm |
| Product Net Weight | 0.132 kg |
| Technical | |
| Function | Phase failure detection |
| Phase sequence monitoring | |
| Over- and undervoltage monitoring | |
| Phase unbalance detection | |
| Measuring Range | (L-L) 300 ... 500 V AC |
| Time Range | Tripping Delay (ON or OFF) 0 second [unit of time] |
| Rated Control Supply Voltage (Us) | (L-L) 300 ... 500 V AC |
| Rated Frequency (f) | Supply Circuit 50/60 Hz |
| Output | 2 C/O Contacts |
| Terminal Type | Screwless Terminals |
| Rated Operational Current AC-12 (Ie) | (230 V) 4 A |
| Rated Operational Current AC-15 (Ie) | (230 V) 3 A |
| Rated Operational Current DC-12 (Ie) | (24 V) 4 A |
| Rated Operational Current DC-13 (Ie) | (24 V) 2 A |
| Minimum Switching Capacity | 24 V |
| 10 mA | |
| Rated Impulse Withstand Voltage (Uimp) | Input Circuit 6 kV |
| Output Circuit 4 kV | |
| Rated Insulation Voltage (Ui) | Input Circuit / Output Circuit 600 V |
| Output Circuit 1 / Output Circuit 2 300 V | |
| Degree of Protection | Housing IP50 |
| Terminals IP20 | |
| Overvoltage Category | III |
| Pollution Degree | 3 |
| Short-Circuit Protective Devices | Output Circuit NC - F Type Fuses 6 A |
| Output Circuit NO - F Type Fuses 10 A | |
| Electrical Durability | AC-12 100000 cycle |
| Mechanical Durability | Nr. Operations 30000000 cycle |
| Connecting Capacity | Flexible with Ferrule 2x 0.5 ... 1.5 mm² |
| Flexible with Insulated Ferrule 2x 0.5 ... 1.5 mm² | |
| Flexible 2x 0.5 ... 1.5 mm² | |
| Rigid 2x 0.5 ... 1.5 mm² | |
| Wire Stripping Length | 8 mm |
| Mounting Position | 1 ... 6 |
| Mounting on DIN Rail | TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715 |
| TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715 | |
| Standards | CAN/CSA C22.2 No.14 |
| IEC/EN 63000 | |
| IEC/EN 60255-27 | |
| IEC/EN 61000-6-2 | |
| IEC/EN 61000-6-3 | |
| UL 508 | |
| Technical UL/CSA | |
| Maximum Operating Voltage UL/CSA | Output Circuit 300 V AC |
| Contact Rating UL/CSA | B300 |
| Connecting Capacity UL/CSA | Flexible 2x 18-16 AWG |
| Rigid 2x 20-16 AWG | |
| Pilot Duty UL/CSA | B300 |
| Flammability According to UL94 | V-0 |
| Environmental | |
| Ambient Air Temperature | Operation -25 ... +60 °C |
| Storage -40 ... +85 °C | |
| Maximum Operating Altitude Permissible | Without Derating 2000 m |
| Material Compliance | |
| Conflict Minerals Reporting Template (CMRT) | 9AKK108467A5658 |
| REACH Declaration | 1SVD981001-4501 |
| RoHS Declaration | 1SVD981001-4401 |
| SCIP | eca0f7be-6d21-4daa-9884-de5aa7a2b438 Germany |
| Simplified SCIP | 04608351-e0a9-4b61-90df-62fd13cb260e Poland |
| 2e9074d5-51d0-410f-93fd-b8820e1f6860 Belgium | |
| 2c6caca4-87c1-42e3-a003-0c0499f99898 Netherlands | |
| 6b843fb9-efc8-4b1d-9f93-dce1c781a4ce Czech Republic | |
| f3e709b7-ac6b-4933-a97d-11ad03d4816c Greece | |
| 98546ade-312f-4e12-8946-8c40ba8f32f7 Norway | |
| 03adec8f-e749-4e54-84cf-a3088c5c69b6 Sweden | |
| fed4608e-917c-45a7-a860-64c17081c6e3 France | |
| aa419d7c-d872-4709-a171-b0c08e500a1c Croatia | |
| 7e5c0290-ea42-45ac-a278-3117a92dd517 Spain | |
| 1ede8f49-58fe-4e4f-926c-a5d9e0ff120f Portugal | |
| 0eed2d95-142e-4be9-885b-7d0184527c52 Hungary | |
| cac09660-516a-424b-af0a-18d76182543f Sweden | |
| 2ea0103e-1677-49d2-9adc-e40b44d49d18 Estonia | |
| 54c9a3ce-0296-4914-9092-b82721ae9643 Poland | |
| 32f013dd-e255-4dc3-afaf-f34104530c25 Germany | |
| e59c9b91-09f9-4ff0-858b-08c0d6e63617 Germany | |
| 7c8d956c-1c79-40f1-8951-082840d6ab76 Poland | |
| 89b071bb-2007-4411-8b9a-83a8f688aca9 Denmark | |
| f4cbc9bf-e750-4101-9326-af5d7f465969 Germany | |
| 354dbca7-9f6b-4d23-8cda-6b29ae8a322e Italy | |
| 9790e411-78de-405e-aae4-0a2a9e9d6250 Belgium | |
| 039897e2-a0f7-43e9-abcd-b539bd91c053 Hungary | |
| 30c21877-d5ea-4bba-8233-e0c544f04198 Bulgaria | |
| c05235dd-b1f8-44d5-86d3-697663dab005 France | |
| b67ee214-de7f-498b-999e-e665bc388be0 Germany | |
| 44c2877e-1eda-4049-881f-77898bb5c6ab Finland | |
| Toxic Substances Control Act - TSCA | 2CMT2023-006536 |
| ABB EcoSolutions | |
| Environmental Product Declaration - EPD | 1SAC200438H0001 |
| Certificates and Declarations | |
| CB Certificate | CB_DK-27947-UL |
| CQC Certificate | CQC2009010303326655 |
| cULus Certificate | cULus508_20120829-E140448 |
| Declaration of Conformity - CCC | 2020980303000197 |
| Declaration of Conformity - CE | 1SVD981014-00 |
| Declaration of Conformity - UKCA | 1SVD981014-10 |
| DNV GL Certificate | DNV_GL_TAA000017D |
| Container Information | |
| Package Level 1 Units | box 1 piece |
| Package Level 1 Width | 97 mm |
| Package Level 1 Depth / Length | 30 mm |
| Package Level 1 Height | 109 mm |
| Package Level 1 Gross Weight | 0.157 kg |
| Package Level 1 EAN | 4016779852043 |
| External Classifications and Standards | |
| Object Classification Code | B |
| ETIM 7 | EC001441 - Phase monitoring relay |
| ETIM 8 | EC001441 - Phase monitoring relay |
| ETIM 9 | EC001441 - Phase monitoring relay |
| eClass | V11.0 : 27371803 |
| UNSPSC | 39122332 |
| E-Number (Finland) | 2712277 |
| E-Number (Norway) | 4188137 |
| E-Number (Sweden) | 3860606 |