View larger
1SVR740884R1300
740884
ABB
1 Pcs.
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
| Ordering | |
|---|---|
| EAN | 4016779852036 |
| Minimum Order Quantity | 1 piece |
| Customs Tariff Number | 85364900 |
| Popular Downloads | |
| Data Sheet, Technical Information | 2CDC112205D0201 |
| Instructions and Manuals | 1SVC730730M1000 |
| 1SVC730730M0000 | |
| CAD Dimensional Drawing | 2CDC001079B0201 |
| EPLAN Data | 9AAC132608_EPLAN |
| Dimensions | |
| Product Net Width | 22.5 mm |
| Product Net Height | 85.6 mm |
| Product Net Depth / Length | 103.7 mm |
| Product Net Weight | 0.133 kg |
| Technical | |
| Function | Phase failure detection |
| Phase sequence monitoring | |
| Over- and undervoltage monitoring | |
| Phase unbalance detection | |
| Measuring Range | (L-L) 160 ... 300 V AC |
| Time Range | Tripping Delay (ON or OFF) 0 second [unit of time] |
| Rated Control Supply Voltage (Us) | (L-L) 160 ... 300 V AC |
| Rated Frequency (f) | Supply Circuit 50/60 Hz |
| Output | 2 C/O Contacts |
| Terminal Type | Screwless Terminals |
| Rated Operational Current AC-12 (Ie) | (230 V) 4 A |
| Rated Operational Current AC-15 (Ie) | (230 V) 3 A |
| Rated Operational Current DC-12 (Ie) | (24 V) 4 A |
| Rated Operational Current DC-13 (Ie) | (24 V) 2 A |
| Minimum Switching Capacity | 24 V |
| 10 mA | |
| Rated Impulse Withstand Voltage (Uimp) | Input Circuit 6 kV |
| Output Circuit 4 kV | |
| Rated Insulation Voltage (Ui) | Input Circuit / Output Circuit 600 V |
| Output Circuit 1 / Output Circuit 2 300 V | |
| Degree of Protection | Housing IP50 |
| Terminals IP20 | |
| Overvoltage Category | III |
| Pollution Degree | 3 |
| Short-Circuit Protective Devices | Output Circuit NC - F Type Fuses 6 A |
| Output Circuit NO - F Type Fuses 10 A | |
| Electrical Durability | AC-12 100000 cycle |
| Mechanical Durability | Nr. Operations 30000000 cycle |
| Connecting Capacity | Flexible with Ferrule 2x 0.5 ... 1.5 mm² |
| Flexible with Insulated Ferrule 2x 0.5 ... 1.5 mm² | |
| Flexible 2x 0.5 ... 1.5 mm² | |
| Rigid 2x 0.5 ... 1.5 mm² | |
| Wire Stripping Length | 8 mm |
| Mounting Position | 1 ... 6 |
| Mounting on DIN Rail | TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715 |
| TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715 | |
| Standards | CAN/CSA C22.2 No.14 |
| IEC/EN 63000 | |
| IEC/EN 60255-27 | |
| IEC/EN 61000-6-2 | |
| IEC/EN 61000-6-3 | |
| UL 508 | |
| Technical UL/CSA | |
| Maximum Operating Voltage UL/CSA | Output Circuit 300 V AC |
| Contact Rating UL/CSA | B300 |
| Connecting Capacity UL/CSA | Flexible 2x 18-16 AWG |
| Rigid 2x 20-16 AWG | |
| Pilot Duty UL/CSA | B300 |
| Flammability According to UL94 | V-0 |
| Environmental | |
| Ambient Air Temperature | Operation -25 ... +60 °C |
| Storage -40 ... +85 °C | |
| Maximum Operating Altitude Permissible | Without Derating 2000 m |
| Material Compliance | |
| Conflict Minerals Reporting Template (CMRT) | 9AKK108467A5658 |
| REACH Declaration | 1SVD981001-4501 |
| RoHS Declaration | 1SVD981001-4401 |
| SCIP | 1f59cba5-6298-4837-87f2-83af802d2bcc Germany |
| Simplified SCIP | f6a0ed88-c6ae-4122-80d8-5fb357c381a8 Italy |
| 8bb22373-0e7e-45b5-af23-e12d4f809a5b Czech Republic | |
| c91dee8b-65ac-486c-bb42-79430203e693 Denmark | |
| a6f551ab-c84d-4024-921e-99cc150899dd Poland | |
| cd445d0f-fb42-4acd-b76a-874e8a75b0c8 Estonia | |
| 71bfab3a-a84c-43b8-bdaf-9c383328b62d Germany | |
| 7d4f1329-6c88-4c16-97e9-114c7c952c15 Croatia | |
| 4715cfea-3d8d-4200-98a6-6820204e9037 Spain | |
| d59fcbd3-d730-4db9-bc64-10462a8eb831 Germany | |
| 4a319246-ad40-4a45-aa93-f30c2a6a2aa4 Portugal | |
| 09f634ff-a0da-4c9b-a8d0-303b90ade5f9 Hungary | |
| 492e28d3-c0d6-4cf8-89cc-2f8eed77c052 Belgium | |
| e62af6c1-1c30-41c5-a12d-43ca8def832e France | |
| 1b020476-c79f-4f3f-82d4-960094506493 France | |
| 0e27bf70-8a6d-4870-b1d9-af93b3168c69 Poland | |
| e9c64ccb-ac9f-4b57-965a-c1876564a9c9 Sweden | |
| 46f25327-7b4b-4ad2-81f3-42efd20e831f Sweden | |
| 209b32b0-d407-4499-bace-65a45344a105 Germany | |
| 4e4ee35b-af46-4606-aff7-c2a0a35443bc Bulgaria | |
| a8259c7b-0f32-4adf-a642-eab2838ef88d Greece | |
| 8f2fc0d9-8d52-4a42-93fe-119f373e9afa Hungary | |
| c56cd66f-033c-495a-b029-228e1e5be7aa Netherlands | |
| fb8c3ef2-d788-46ec-8154-642bed2fc28b Poland | |
| 9ef257e6-9f1c-4154-979e-b5cf719ace83 Germany | |
| 8fa6c35c-2291-46af-8030-0021dc57c7fd Belgium | |
| 30ae89e9-a6a3-43f3-8c97-2511e875ad86 Finland | |
| d0caeca2-6579-4e28-a328-3c0f620a1209 Norway | |
| Toxic Substances Control Act - TSCA | 2CMT2023-006536 |
| ABB EcoSolutions | |
| Environmental Product Declaration - EPD | 1SAC200438H0001 |
| Certificates and Declarations | |
| CB Certificate | CB_DK-27947-UL |
| CQC Certificate | CQC2009010303326655 |
| cULus Certificate | cULus508_20120829-E140448 |
| Declaration of Conformity - CCC | 2020980303000197 |
| Declaration of Conformity - CE | 1SVD981014-00 |
| Declaration of Conformity - UKCA | 1SVD981014-10 |
| DNV GL Certificate | DNV_GL_TAA000017D |
| Container Information | |
| Package Level 1 Units | box 1 piece |
| Package Level 1 Width | 97 mm |
| Package Level 1 Depth / Length | 30 mm |
| Package Level 1 Height | 109 mm |
| Package Level 1 Gross Weight | 0.158 kg |
| Package Level 1 EAN | 4016779852036 |
| External Classifications and Standards | |
| Object Classification Code | B |
| ETIM 7 | EC001441 - Phase monitoring relay |
| ETIM 8 | EC001441 - Phase monitoring relay |
| ETIM 9 | EC001441 - Phase monitoring relay |
| eClass | V11.0 : 27371803 |
| UNSPSC | 39122332 |
| E-Number (Finland) | 2712275 |
| E-Number (Norway) | 4188135 |
| E-Number (Sweden) | 3860605 |