ABB 1SVR740885R1300 1SVR740885R1300 ABB CM-MPS.11P Three-phase monitoring relay 2c/o, 0,0.1-30s, L1-L2-L3-N 3x90-170VAC View larger
Images are for illustrative purposes only. Please refer to data sheet for details

1SVR740885R1300 ABB CM-MPS.11P Three-phase monitoring relay 2c/o, 0,0.1-30s, L1-L2-L3-N 3x90-170VAC

1SVR740885R1300

740885

ABB

1 Pcs.

CM-MPS.11P Three-phase monitoring relay 2c/o, 0,0.1-30s, L1-L2-L3-N=3x90-170VAC CM-MPS.11P RELe CTRL TRIFaSICO 2 C/C RES

Automation > Phase monitoring relay
Monitoring

Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.

Request a Quote

Pricing and availability are confirmed for each enquiry. Add your required quantity to begin.

No account, online checkout or payment is required.

More info

Ordering
EAN4016779852067
Minimum Order Quantity1 piece
Customs Tariff Number85364900
Popular Downloads
Data Sheet, Technical Information2CDC112205D0201
Instructions and Manuals1SVC730730M1000
1SVC730730M0000
CAD Dimensional Drawing2CDC001079B0201
EPLAN Data9AAC132608_EPLAN
Dimensions
Product Net Width22.5 mm
Product Net Height85.6 mm
Product Net Depth / Length103.7 mm
Product Net Weight0.137 kg
Technical
FunctionOver- and undervoltage monitoring
Phase failure detection
Phase unbalance detection
Phase sequence monitoring
Interrupted neutral monitoring
Measuring Range(L-N) 90 ... 170 V AC
Time RangeTripping Delay (ON or OFF) 0 second [unit of time]
Rated Control Supply Voltage (Us)(L-N) 90 ... 170 V AC
Rated Frequency (f)Supply Circuit 50/60 Hz
Output2 C/O Contacts
Terminal TypeScrewless Terminals
Rated Operational Current AC-12 (Ie)(230 V) 4 A
Rated Operational Current AC-15 (Ie)(230 V) 3 A
Rated Operational Current DC-12 (Ie)(24 V) 4 A
Rated Operational Current DC-13 (Ie)(24 V) 2 A
Minimum Switching Capacity24 V
10 mA
Rated Impulse Withstand Voltage (Uimp)Input Circuit 6 kV
Output Circuit 4 kV
Rated Insulation Voltage (Ui)Input Circuit / Output Circuit 600 V
Output Circuit 1 / Output Circuit 2 300 V
Degree of ProtectionHousing IP50
Terminals IP20
Overvoltage CategoryIII
Pollution Degree3
Short-Circuit Protective DevicesOutput Circuit NC - F Type Fuses 6 A
Output Circuit NO - F Type Fuses 10 A
Electrical DurabilityAC-12 100000 cycle
Mechanical DurabilityNr. Operations 30000000 cycle
Connecting CapacityFlexible with Ferrule 2x 0.5 ... 1.5 mm²
Flexible with Insulated Ferrule 2x 0.5 ... 1.5 mm²
Flexible 2x 0.5 ... 1.5 mm²
Rigid 2x 0.5 ... 1.5 mm²
Wire Stripping Length8 mm
Mounting Position1 ... 6
Mounting on DIN RailTH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715
StandardsCAN/CSA C22.2 No.14
IEC/EN 63000
IEC/EN 60255-27
IEC/EN 61000-6-2
IEC/EN 61000-6-3
UL 508
Technical UL/CSA
Maximum Operating Voltage UL/CSAOutput Circuit 300 V AC
Contact Rating UL/CSAB300
Connecting Capacity UL/CSAFlexible 2x 18-16 AWG
Rigid 2x 20-16 AWG
Pilot Duty UL/CSAB300
Flammability According to UL94V-0
Environmental
Ambient Air TemperatureOperation -25 ... +60 °C
Storage -40 ... +85 °C
Maximum Operating Altitude PermissibleWithout Derating 2000 m
Material Compliance
Conflict Minerals Reporting Template (CMRT)9AKK108467A5658
REACH Declaration1SVD981001-4501
RoHS Declaration1SVD981001-4401
SCIP4d1afad1-0abe-4022-bca9-419040c1fa38 Germany
Simplified SCIP6d20e6ef-76c2-4407-b760-46f0cc62c772 Hungary
213270b5-4a24-47d8-a1ea-7ed489cec131 Netherlands
906d6e7b-903f-4e3b-8431-9e43f82267ee Denmark
4977273d-207f-4d91-8054-6c49649b1fe1 Poland
a1fb97cb-780f-4c26-adb8-7df22d8896bb Norway
5f5f869c-1e2e-4616-858c-9b93ec131d35 Estonia
a3e73b03-f4f2-477d-bf5e-7eaa7f7f5b74 Croatia
bc924c40-5a32-4661-97a1-ca98733fb4c5 Germany
ff4fc583-71b8-4da1-8656-d02e64ba3ce7 Czech Republic
6f84e828-e4af-4e6c-89d1-95f6b82cbf47 Italy
d4eb48b9-55ff-468c-a63d-ffc70a4879c6 Spain
c10f071b-c1ba-4709-ad4e-a64f9ef0a677 Poland
3f29626f-c93c-4e7c-8bb8-fcc1d61f1fde Bulgaria
85513ba0-2bfc-4600-81d2-dfd0284d06dd Portugal
4ac946ce-998a-408c-a80e-018b33652627 Greece
5d9f499d-b8c0-4559-a3cd-e103cec5c6a7 Poland
0d1bfd8c-e080-43aa-a032-5a1d17b2e984 Sweden
86442d29-cfb5-44dc-a7d2-3fa199a60505 Germany
528870a8-cb30-495a-ac14-8034dac69817 Sweden
64ee8ea1-868b-49fb-b2b6-be7ed04d2206 France
f1329cec-6cda-4670-9d53-7624bf5e8d19 France
fa2c69cd-a79a-4f23-b14e-b9772b9fa861 Hungary
99577bea-fb54-41c6-aaab-a70efe0918dc Belgium
67c4d37c-a871-46f5-8939-5cf43c909620 Germany
afa8c4fe-838b-40bf-8fc8-46f1b6a43aea Belgium
5caa1559-b3b8-4ea5-a620-85852a254525 Germany
61d00f71-2e61-4eb8-a82c-99aec869d9f6 Finland
Toxic Substances Control Act - TSCA2CMT2023-006536
ABB EcoSolutions
Environmental Product Declaration - EPD1SAC200438H0001
Certificates and Declarations
CB CertificateCB_DK-27947-UL
CQC CertificateCQC2009010303326655
cULus CertificatecULus508_20120829-E140448
Declaration of Conformity - CCC2020980303000197
Declaration of Conformity - CE1SVD981014-00
Declaration of Conformity - UKCA1SVD981014-10
DNV GL CertificateDNV_GL_TAA000017D
Container Information
Package Level 1 Unitsbox 1 piece
Package Level 1 Width97 mm
Package Level 1 Depth / Length30 mm
Package Level 1 Height109 mm
Package Level 1 Gross Weight0.162 kg
Package Level 1 EAN4016779852067
External Classifications and Standards
Object Classification CodeB
ETIM 7EC001441 - Phase monitoring relay
ETIM 8EC001441 - Phase monitoring relay
ETIM 9EC001441 - Phase monitoring relay
eClassV11.0 : 27371803
UNSPSC39122332
E-Number (Finland)2712269
E-Number (Norway)4188131
E-Number (Sweden)3860608

Product Datasheet

Electrica Online Product Datasheet Prepared from the current product description, catalog data and structured technical attributes.