ABB 1SVR760489R8300 1SVR760489R8300 ABB CM-MPN.72P Three-phase monitoring relay 2c/o, 0,0.1-30s, L1-L2-L3 3x530-820VAC View larger
Images are for illustrative purposes only. Please refer to data sheet for details

1SVR760489R8300 ABB CM-MPN.72P Three-phase monitoring relay 2c/o, 0,0.1-30s, L1-L2-L3 3x530-820VAC

1SVR760489R8300

760489

ABB

1 Pcs.

CM-MPN.72P Three-phase monitoring relay 2c/o, 0,0.1-30s, L1-L2-L3=3x530-820VAC CM-MPN.72P RELe CTRL TRIFaSICO 2 C/C RES

Automation > Phase monitoring relay
Monitoring

Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.

Request a Quote

Pricing and availability are confirmed for each enquiry. Add your required quantity to begin.

No account, online checkout or payment is required.

More info

Ordering
EAN4016779852111
Minimum Order Quantity1 piece
Customs Tariff Number85364900
Popular Downloads
Data Sheet, Technical Information2CDC112177D0201
Instructions and Manuals1SVC730730M1000
1SVC730730M0000
CAD Dimensional Drawing2CDC001079B0201
EPLAN Data9AAC132608_EPLAN
Dimensions
Product Net Width45 mm
Product Net Height85.6 mm
Product Net Depth / Length104.8 mm
Product Net Weight0.22 kg
Technical
FunctionAutomatic phase sequence correction
Over- and undervoltage monitoring
Phase failure detection
Phase unbalance detection
Phase sequence monitoring
Measuring Range(L-L) 530 ... 820 V AC
Time RangeTripping Delay (ON or OFF) 0 second [unit of time]
Rated Control Supply Voltage (Us)(L-L) 530 ... 820 V AC
Rated Frequency (f)Supply Circuit 50/60 Hz
Output2 x 1 c/o or 1 x 2 c/o contacts, configurable
Terminal TypeScrewless Terminals
Rated Operational Current AC-12 (Ie)(230 V) 4 A
Rated Operational Current AC-15 (Ie)(230 V) 3 A
Rated Operational Current DC-12 (Ie)(24 V) 4 A
Rated Operational Current DC-13 (Ie)(24 V) 2 A
Minimum Switching Capacity24 V
10 mA
Rated Impulse Withstand Voltage (Uimp)Input Circuit 8 kV
Output Circuit 4 kV
Rated Insulation Voltage (Ui)Input Circuit / Output Circuit 1000 V
Output Circuit 1 / Output Circuit 2 300 V
Degree of ProtectionHousing IP50
Terminals IP20
Overvoltage CategoryIII
Pollution Degree3
Short-Circuit Protective DevicesOutput Circuit NC - F Type Fuses 6 A
Output Circuit NO - F Type Fuses 10 A
Electrical DurabilityAC-12 100000 cycle
Mechanical DurabilityNr. Operations 30000000 cycle
Connecting CapacityFlexible with Ferrule 2x 0.5 ... 1.5 mm²
Flexible with Insulated Ferrule 2x 0.5 ... 1.5 mm²
Flexible 2x 0.5 ... 1.5 mm²
Rigid 2x 0.5 ... 1.5 mm²
Wire Stripping Length8 mm
Mounting Position1 ... 6
Mounting on DIN RailTH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715
StandardsIEC/EN 63000
IEC/EN 60255-27
IEC/EN 61000-6-2
IEC/EN 61000-6-3
Technical UL/CSA
Maximum Operating Voltage UL/CSAOutput Circuit 300 V AC
Contact Rating UL/CSAB300
Connecting Capacity UL/CSAFlexible 2x 18-16 AWG
Rigid 2x 20-16 AWG
Pilot Duty UL/CSAB300
Flammability According to UL94V-0
Environmental
Ambient Air TemperatureOperation -25 ... +60 °C
Storage -40 ... +85 °C
Maximum Operating Altitude PermissibleWithout Derating 2000 m
Material Compliance
Conflict Minerals Reporting Template (CMRT)9AKK108467A5658
REACH Declaration1SVD981001-4501
RoHS Declaration1SVD981001-4401
SCIPc2c3e5f9-6bb9-454c-b15b-3ee566f44a5f Germany
Simplified SCIP69e4c081-346c-4283-ab38-52a7dfb4b30c Spain
08ddd7ab-4990-4304-9d27-9ca1cbfcd422 Poland
9c69695b-2be1-4d42-9cb7-89fcbb419e45 Estonia
fcab1f8c-f276-4556-9af3-08451d987bb9 Netherlands
6ce4a652-bfa7-4a20-a39d-d890c03c9fd3 Portugal
840e7c4c-8b84-4ce4-9b48-78f3efbcf964 Greece
6d47dea6-e09c-483e-8fd8-20ff04f69eb7 Hungary
3e0bbe22-d825-4bfc-9c18-65efb66c62e3 Sweden
afd007a9-150a-4f90-b60c-dc736ef96861 Poland
801530e6-115e-46e7-b017-35f41b339571 France
a2542a0f-f822-494d-8a80-bac9ff1e36ab Bulgaria
d6f3652a-47c5-446d-b6e4-afe3807ad575 Germany
eaadb109-b2c6-41fa-a25b-c093dc8ef83f Sweden
01719ace-68a2-418a-b71a-99b6c0921976 Belgium
2ed98412-33c1-4479-8e94-387b2cda6913 Finland
8b4a1a59-a9bb-43bb-9d7d-918cb4df522b Norway
455077b4-d089-4f05-9a41-09886b1bc238 Germany
1004c885-223e-4ac2-878d-6bebcbd9e9e6 France
b0f6d74f-2804-4583-abd6-c5aaaf13a27f Hungary
166ab94e-8b4b-4701-8083-d34f75d92e42 Belgium
d180948c-7809-4193-b546-a15b1faf434d Italy
c4dc960c-b4e1-4b65-b326-96254b97d194 Germany
c0529b25-1238-4bee-b422-6914433d4edb Czech Republic
d39373b5-0fe5-4011-bcb9-d37e5a66788d Croatia
5a3d1489-f6f9-4d7b-b444-127212be00d7 Germany
953715af-b894-4de1-9ef0-bd89caa53f27 Denmark
da5cf0d5-dffb-4ee5-a07d-6032d65c0a97 Poland
Toxic Substances Control Act - TSCA2CMT2023-006536
ABB EcoSolutions
Environmental Product Declaration - EPD1SAC200438H0001
Certificates and Declarations
CB CertificateCB_DK-27946-UL
CQC CertificateCQC2009010303326655
Declaration of Conformity - CCC2020980303000197
Declaration of Conformity - CE1SVD981014-00
Declaration of Conformity - UKCA1SVD981014-10
DNV GL CertificateDNV_GL_TAA000017D
Container Information
Package Level 1 Unitsbox 1 piece
Package Level 1 Width97 mm
Package Level 1 Depth / Length52.5 mm
Package Level 1 Height109 mm
Package Level 1 Gross Weight0.245 kg
Package Level 1 EAN4016779852111
External Classifications and Standards
Object Classification CodeB
ETIM 7EC001441 - Phase monitoring relay
ETIM 8EC001441 - Phase monitoring relay
ETIM 9EC001441 - Phase monitoring relay
eClassV11.0 : 27371803
UNSPSC39122332
E-Number (Finland)2712267
E-Number (Norway)4188147
E-Number (Sweden)3860613

Product Datasheet

Electrica Online Product Datasheet Prepared from the current product description, catalog data and structured technical attributes.