ABB 1SVR750488R8300 1SVR750488R8300 ABB CM-MPN.62S Three-phase monitoring relay 2c/o, 0,0.1-30s, L1-L2-L3 3x450-720VAC View larger
Images are for illustrative purposes only. Please refer to data sheet for details

1SVR750488R8300 ABB CM-MPN.62S Three-phase monitoring relay 2c/o, 0,0.1-30s, L1-L2-L3 3x450-720VAC

1SVR750488R8300

750488

ABB

1 Pcs.

CM-MPN.62S Three-phase monitoring relay 2c/o, 0,0.1-30s, L1-L2-L3=3x450-720VAC CM-MPN.62S CTRL THREE-PHASE 2 C/C TOR RELAY

Automation > Phase monitoring relay
Monitoring

Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.

Request a Quote

Pricing and availability are confirmed for each enquiry. Add your required quantity to begin.

No account, online checkout or payment is required.

More info

Ordering
EAN4016779851923
Minimum Order Quantity1 piece
Customs Tariff Number85364900
Popular Downloads
Data Sheet, Technical Information2CDC112177D0201
Instructions and Manuals1SVC730730M1000
1SVC730730M0000
CAD Dimensional Drawing2CDC001079B0201
EPLAN Data9AAC132608_EPLAN
Dimensions
Product Net Width45 mm
Product Net Height85.6 mm
Product Net Depth / Length104.8 mm
Product Net Weight0.229 kg
Technical
FunctionAutomatic phase sequence correction
Over- and undervoltage monitoring
Phase failure detection
Phase unbalance detection
Phase sequence monitoring
Measuring Range(L-L) 450 ... 720 V AC
Time RangeTripping Delay (ON or OFF) 0 second [unit of time]
Rated Control Supply Voltage (Us)(L-L) 450 ... 720 V AC
Rated Frequency (f)Supply Circuit 50/60 Hz
Output2x 1 C/O or 1x 2 C/O Contact, Configurable
Terminal TypeScrew Terminals
Rated Operational Current AC-12 (Ie)(230 V) 4 A
Rated Operational Current AC-15 (Ie)(230 V) 3 A
Rated Operational Current DC-12 (Ie)(24 V) 4 A
Rated Operational Current DC-13 (Ie)(24 V) 2 A
Minimum Switching Capacity24 V
10 mA
Rated Impulse Withstand Voltage (Uimp)Input Circuit 8 kV
Output Circuit 4 kV
Rated Insulation Voltage (Ui)Input Circuit / Output Circuit 1000 V
Output Circuit 1 / Output Circuit 2 300 V
Degree of ProtectionHousing IP50
Terminals IP20
Overvoltage CategoryIII
Pollution Degree3
Short-Circuit Protective DevicesOutput Circuit NC - F Type Fuses 6 A
Output Circuit NO - F Type Fuses 10 A
Electrical DurabilityAC-12 100000 cycle
Mechanical DurabilityNr. Operations 30000000 cycle
Connecting CapacityFlexible with Ferrule 1x 0.5 ... 2.5 mm²
Flexible with Ferrule 2x 0.5 ... 1.5 mm²
Flexible with Insulated Ferrule 1x 0.5 ... 2.5 mm²
Flexible with Insulated Ferrule 2x 0.5 ... 1.5 mm²
Flexible 1x 0.5 ... 2.5 mm²
Flexible 2x 0.5 ... 1.5 mm²
Rigid 1x 0.5 ... 4 mm²
Rigid 2x 0.5 ... 2.5 mm²
Tightening Torque0.6 ... 0.8 N·m
Wire Stripping Length8 mm
Recommended Screw Driver4.5
0.8 x 4
Pozidriv 1
Mounting Position1 ... 6
Mounting on DIN RailTH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715
StandardsCAN/CSA C22.2 No.14
IEC/EN 63000
IEC/EN 60255-27
IEC/EN 61000-6-2
IEC/EN 61000-6-3
UL 508
Technical UL/CSA
Maximum Operating Voltage UL/CSAOutput Circuit 300 V AC
Contact Rating UL/CSAB300
Connecting Capacity UL/CSAFlexible 1x 18-14 AWG
Flexible 2x 18-16 AWG
Rigid 2x 20-14 AWG
Rigid 1x 20-12 AWG
Tightening Torque UL/CSA7.08 in·lb
Pilot Duty UL/CSAB300
Flammability According to UL94V-0
Environmental
Ambient Air TemperatureOperation -25 ... +60 °C
Storage -40 ... +85 °C
Maximum Operating Altitude PermissibleWithout Derating 2000 m
Material Compliance
Conflict Minerals Reporting Template (CMRT)9AKK108467A5658
REACH Declaration1SVD981001-4501
RoHS Declaration1SVD981001-4401
SCIPed8406db-b97c-4121-a8ab-f4c938737332 Germany
Simplified SCIPa743da96-07b1-4512-b1a3-e8870c3c04bc Germany
596e5c42-317c-42c4-aec6-5d102e078f00 Germany
bd87286b-b527-420b-aa5f-530cd58e0645 Belgium
3c13dd38-6ef6-47f8-9cab-3c5d7859ccd2 Spain
21fd10cc-8e47-4fcc-ad74-735c765c5dce France
f199a684-090d-4a18-9c09-c5f842bde5b5 Sweden
5bdcbcf8-23c5-4d0c-a82b-8803d04c8810 Sweden
8af1df27-815f-4875-87ba-1e87f6fae979 Poland
dddebbb3-ebe3-41b3-b02d-99e23fba9bde France
a2468177-5115-43eb-b88d-2a987faadf14 Hungary
1719eedc-510c-4e76-b162-4ada9b424a07 Belgium
504f76ac-7d6c-46cf-af26-4a5199414bb5 Netherlands
d46f6dfe-be19-4aa3-bcda-904e7a7513ba Poland
f21400b8-6000-4908-9b0f-5c719238aaad Hungary
33eec99d-5cae-47b2-b29b-ab5969a7ce86 Greece
8b35842f-9962-4c83-b0ae-de2cb0803565 Portugal
c11f42de-7049-4914-8d6e-4d5099bd0e82 Bulgaria
f6ad2335-7d96-4207-a2cc-4b2e660a867e Germany
c1eca859-ac61-4fa9-b121-bffb4de2e7d8 Italy
77105afd-4155-4212-92d3-c717e214c9d5 Estonia
180a6f4d-0e0d-4836-b89d-bda3c4fb7103 Croatia
61c288ed-d0a8-49b9-b22c-0768269c8f74 Germany
aa76cdbe-b189-4e3b-9031-27577d1ac39d Denmark
8416e21a-06ec-4b7e-ab21-d40c62540bc6 Czech Republic
7a77d4a3-c650-4917-8c4a-f023578e0d1a Norway
65d2d722-ff32-48d7-9e6b-e25bc27806b8 Poland
b50c1051-ffb2-4f5f-acf7-8cf48e82de1e Finland
Toxic Substances Control Act - TSCA2CMT2023-006536
ABB EcoSolutions
ABB EcoSolutionsYes
Environmental Product Declaration - EPD1SAC200438H0001
Certificates and Declarations
CB CertificateCB_DK-27946-UL
CQC CertificateCQC2009010303326655
cULus CertificatecULus508_20120829-E140448
Declaration of Conformity - CCC2020980303000197
Declaration of Conformity - CE1SVD981014-00
Declaration of Conformity - UKCA1SVD981014-10
DNV GL CertificateDNV_GL_TAA000017D
Container Information
Package Level 1 Unitsbox 1 piece
Package Level 1 Width97 mm
Package Level 1 Depth / Length52.5 mm
Package Level 1 Height109 mm
Package Level 1 Gross Weight0.254 kg
Package Level 1 EAN4016779851923
External Classifications and Standards
Object Classification CodeB
ETIM 7EC001441 - Phase monitoring relay
ETIM 8EC001441 - Phase monitoring relay
ETIM 9EC001441 - Phase monitoring relay
eClassV11.0 : 27371803
UNSPSC39122332
E-Number (Finland)2712266
E-Number (Norway)4188144
E-Number (Sweden)3860593

Product Datasheet

Electrica Online Product Datasheet Prepared from the current product description, catalog data and structured technical attributes.