View larger
1SVR750487R8300 ABB CM-MPN.52S Three-phase monitoring relay 2c/o, 0,0.1-30s, L1-L2-L3 3x350-580VAC
1SVR750487R8300
750487
ABB
1 Pcs.
Automation > Phase monitoring relay
Monitoring
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
Abb 1SVR750487R8300 CM-MPN.52S Three-phase monitoring relay provides continuous line surveillance in electrical control panels, safeguarding rotating equipment and motors from supply anomalies such as incorrect phase rotation or voltage sags. Implementing this hardware ensures automated processes safely disconnect before electrical faults cascade through the facility. Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- EAN: 4016779851916
- Minimum Order Quantity: 1 piece
- Customs Tariff Number: 85364900
- Data Sheet, Technical Information: 2CDC112177D0201
- Instructions and Manuals: 1SVC730730M1000
- CAD Dimensional Drawing: 2CDC001079B0201
- EPLAN Data: 9AAC132608_EPLAN
- Product Net Width: 45 mm
- Product Net Height: 85.6 mm
- Product Net Depth / Length: 104.8 mm
- Product Net Weight: 0.23 kg
- Function: Automatic phase sequence correction
- Measuring Range: (L-L) 350 ... 580 V AC
- Time Range: Tripping Delay (ON or OFF) 0 second [unit of time]
- Rated Control Supply Voltage (U s ): (L-L) 350 ... 580 V AC
- Rated Frequency (f): Supply Circuit 50/60 Hz
More info
▲| Ordering | |
|---|---|
| EAN | 4016779851916 |
| Minimum Order Quantity | 1 piece |
| Customs Tariff Number | 85364900 |
| Popular Downloads | |
| Data Sheet, Technical Information | 2CDC112177D0201 |
| Instructions and Manuals | 1SVC730730M1000 |
| 1SVC730730M0000 | |
| CAD Dimensional Drawing | 2CDC001079B0201 |
| EPLAN Data | 9AAC132608_EPLAN |
| Dimensions | |
| Product Net Width | 45 mm |
| Product Net Height | 85.6 mm |
| Product Net Depth / Length | 104.8 mm |
| Product Net Weight | 0.23 kg |
| Technical | |
| Function | Automatic phase sequence correction |
| Over- and undervoltage monitoring | |
| Phase failure detection | |
| Phase unbalance detection | |
| Phase sequence monitoring | |
| Measuring Range | (L-L) 350 ... 580 V AC |
| Time Range | Tripping Delay (ON or OFF) 0 second [unit of time] |
| Rated Control Supply Voltage (Us) | (L-L) 350 ... 580 V AC |
| Rated Frequency (f) | Supply Circuit 50/60 Hz |
| Output | 2x 1 C/O or 1x 2 C/O Contact, Configurable |
| Terminal Type | Screw Terminals |
| Rated Operational Current AC-12 (Ie) | (230 V) 4 A |
| Rated Operational Current AC-15 (Ie) | (230 V) 3 A |
| Rated Operational Current DC-12 (Ie) | (24 V) 4 A |
| Rated Operational Current DC-13 (Ie) | (24 V) 2 A |
| Minimum Switching Capacity | 24 V |
| 10 mA | |
| Rated Impulse Withstand Voltage (Uimp) | Input Circuit 8 kV |
| Output Circuit 4 kV | |
| Rated Insulation Voltage (Ui) | Input Circuit / Output Circuit 1000 V |
| Output Circuit 1 / Output Circuit 2 300 V | |
| Degree of Protection | Housing IP50 |
| Terminals IP20 | |
| Overvoltage Category | III |
| Pollution Degree | 3 |
| Short-Circuit Protective Devices | Output Circuit NC - F Type Fuses 6 A |
| Output Circuit NO - F Type Fuses 10 A | |
| Electrical Durability | AC-12 100000 cycle |
| Mechanical Durability | Nr. Operations 30000000 cycle |
| Connecting Capacity | Flexible with Ferrule 1x 0.5 ... 2.5 mm² |
| Flexible with Ferrule 2x 0.5 ... 1.5 mm² | |
| Flexible with Insulated Ferrule 1x 0.5 ... 2.5 mm² | |
| Flexible with Insulated Ferrule 2x 0.5 ... 1.5 mm² | |
| Flexible 1x 0.5 ... 2.5 mm² | |
| Flexible 2x 0.5 ... 1.5 mm² | |
| Rigid 1x 0.5 ... 4 mm² | |
| Rigid 2x 0.5 ... 2.5 mm² | |
| Tightening Torque | 0.6 ... 0.8 N·m |
| Wire Stripping Length | 8 mm |
| Recommended Screw Driver | 4.5 |
| 0.8 x 4 | |
| Pozidriv 1 | |
| Mounting Position | 1 ... 6 |
| Mounting on DIN Rail | TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715 |
| TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715 | |
| Standards | CAN/CSA C22.2 No.14 |
| IEC/EN 63000 | |
| IEC/EN 60255-27 | |
| IEC/EN 61000-6-2 | |
| IEC/EN 61000-6-3 | |
| UL 508 | |
| Technical UL/CSA | |
| Maximum Operating Voltage UL/CSA | Output Circuit 300 V AC |
| Contact Rating UL/CSA | B300 |
| Connecting Capacity UL/CSA | Flexible 1x 18-14 AWG |
| Flexible 2x 18-16 AWG | |
| Rigid 2x 20-14 AWG | |
| Rigid 1x 20-12 AWG | |
| Tightening Torque UL/CSA | 7.08 in·lb |
| Pilot Duty UL/CSA | B300 |
| Flammability According to UL94 | V-0 |
| Environmental | |
| Ambient Air Temperature | Operation -25 ... +60 °C |
| Storage -40 ... +85 °C | |
| Maximum Operating Altitude Permissible | Without Derating 2000 m |
| Material Compliance | |
| Conflict Minerals Reporting Template (CMRT) | 9AKK108467A5658 |
| REACH Declaration | 1SVD981001-4501 |
| RoHS Declaration | 1SVD981001-4401 |
| SCIP | 18ca17d6-2ee2-4032-8491-bbfa958e51cd Germany |
| Simplified SCIP | 0e8d140a-937f-490c-aaa1-0d2675327dbe Czech Republic |
| 9db76a38-00e0-4331-9ba4-5489d0f46a19 Germany | |
| 98aec040-4c44-4d48-b6c9-f076cd3f785c Finland | |
| 87860bd9-4538-4d3a-bd8b-7c761476ee37 Poland | |
| 9fa1c523-b851-4718-a2dd-9fed569baab0 Germany | |
| 5cc49002-4a32-4aa0-b32c-d4bcf078c6e0 Belgium | |
| ebffd709-3f87-46af-ab38-c8517d5d8aab Germany | |
| 2fd6b0ae-dc89-4d32-81b4-6fd797e5ade7 Norway | |
| 12e64027-c1cd-4942-acaa-1d8b2f27a2c9 Belgium | |
| d64404c3-0234-4979-9ee9-86daf9e2e89d Hungary | |
| 74aaa3b9-d593-42c3-bdf9-ca434af5fcf9 Poland | |
| a3a6ccda-47b1-432e-b916-a01e89e3ea15 Sweden | |
| 84baa07f-dfb9-4d85-b601-6beff13fa492 Sweden | |
| dd0df817-d5e6-4fb9-ac4a-ad63718732d2 Germany | |
| 51ec9fe5-ca65-4af0-8be2-73e1ab10c705 France | |
| 9f5ff44b-412d-4352-b3db-485f0b2a0977 France | |
| 0c5d8c44-6e36-4f3d-80c3-31ee3622a7d7 Spain | |
| 4fe377c8-26aa-4921-a25b-9ae384da6a85 Netherlands | |
| 64113f20-dc6d-425e-a181-10f390a6e3cb Hungary | |
| 08c5cdf9-4732-42e6-961b-ebb72f070eac Greece | |
| 70098e21-6e9d-4ec6-86f6-fdb3034334eb Poland | |
| a5389ac7-a89e-42c1-8824-ad3f6e898f59 Estonia | |
| c5cb26f3-8f08-4aae-ad5c-bdd02ebd7134 Croatia | |
| d2db2f11-2993-443b-ab77-9a6189a79de3 Portugal | |
| 242adf74-365a-47c9-a83f-517adbf053c5 Bulgaria | |
| 4f59d0f0-b0a7-4bb9-9296-5b7a91fe1e71 Denmark | |
| a9ad2a4b-c9ab-49a5-a6a1-00610818fa56 Italy | |
| Toxic Substances Control Act - TSCA | 2CMT2023-006536 |
| ABB EcoSolutions | |
| ABB EcoSolutions | Yes |
| Environmental Product Declaration - EPD | 1SAC200438H0001 |
| Certificates and Declarations | |
| CB Certificate | CB_DK-27946-UL |
| CQC Certificate | CQC2009010303326655 |
| cULus Certificate | cULus508_20120829-E140448 |
| Declaration of Conformity - CCC | 2020980303000197 |
| Declaration of Conformity - CE | 1SVD981014-00 |
| Declaration of Conformity - UKCA | 1SVD981014-10 |
| DNV GL Certificate | DNV_GL_TAA000017D |
| Container Information | |
| Package Level 1 Units | box 1 piece |
| Package Level 1 Width | 97 mm |
| Package Level 1 Depth / Length | 52.5 mm |
| Package Level 1 Height | 109 mm |
| Package Level 1 Gross Weight | 0.255 kg |
| Package Level 1 EAN | 4016779851916 |
| External Classifications and Standards | |
| Object Classification Code | B |
| ETIM 7 | EC001441 - Phase monitoring relay |
| ETIM 8 | EC001441 - Phase monitoring relay |
| ETIM 9 | EC001441 - Phase monitoring relay |
| eClass | V11.0 : 27371803 |
| UNSPSC | 39122332 |
| E-Number (Finland) | 2712264 |
| E-Number (Norway) | 4188142 |