View larger
1SVR730850R0100 ABB CM-ENS.11S Liquid level monitoring relay 1c/o, sensitivity 5-100kOhm
1SVR730850R0100
730850
ABB
1 Pcs.
Automation > (Fill) level monitoring relay
Monitoring
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
An 1SVR730850R0100 ABB CM-ENS.11S Liquid level monitoring relay 1c/o, sensitivity 5-100kOhm monitors conductive liquids to automate tank filling or draining tasks and protect equipment from running dry. Liquid level monitoring relays process signals from immersed electrodes to maintain safe fluid boundaries in industrial setups.
Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- EAN: 4013614502934
- Minimum Order Quantity: 1 piece
- Customs Tariff Number: 85364900
- Data Sheet, Technical Information: 2CDC112228D0201
- Instructions and Manuals: 1SVC730680M1001
- CAD Dimensional Drawing: 2CDC001079B0201
- EPLAN Data: 9AAC132575_EPLAN
- Product Net Width: 22.5 mm
- Product Net Height: 85.6 mm
- Product Net Depth / Length: 103.7 mm
- Product Net Weight: 0.124 kg
- Function: Filling or draining monitoring
- Number of Electrodes: 3
- Measuring Range: 5 ... 100 kΩ
- Rated Control Supply Voltage (U s ): 24 ... 240 V AC/DC
- Rated Frequency (f): Supply Circuit 50/60 Hz
More info
▲| Ordering | |
|---|---|
| EAN | 4013614502934 |
| Minimum Order Quantity | 1 piece |
| Customs Tariff Number | 85364900 |
| Popular Downloads | |
| Data Sheet, Technical Information | 2CDC112228D0201 |
| Instructions and Manuals | 1SVC730680M1001 |
| 1SVC730680M0001 | |
| CAD Dimensional Drawing | 2CDC001079B0201 |
| EPLAN Data | 9AAC132575_EPLAN |
| Dimensions | |
| Product Net Width | 22.5 mm |
| Product Net Height | 85.6 mm |
| Product Net Depth / Length | 103.7 mm |
| Product Net Weight | 0.124 kg |
| Technical | |
| Function | Filling or draining monitoring |
| Number of Electrodes | 3 |
| Measuring Range | 5 ... 100 kΩ |
| Rated Control Supply Voltage (Us) | 24 ... 240 V AC/DC |
| Rated Frequency (f) | Supply Circuit 50/60 Hz |
| Output | 1 C/O (SPDT) Contact |
| Terminal Type | Screw Terminals |
| Rated Operational Current AC-12 (Ie) | (230 V) 4 A |
| Rated Operational Current AC-15 (Ie) | (230 V) 3 A |
| Rated Operational Current DC-12 (Ie) | (24 V) 4 A |
| Rated Operational Current DC-13 (Ie) | (24 V) 2 A |
| Minimum Switching Capacity | 12 V |
| 10 mA | |
| Rated Impulse Withstand Voltage (Uimp) | Measuring Circuit / Output Circuit 4 kV |
| Output Circuit 1 / Output Circuit 2 4 kV | |
| Supply Circuit / Measuring Circuit 4 kV | |
| Supply Circuit / Output Circuit 4 kV | |
| Rated Insulation Voltage (Ui) | Measuring Circuit / Output Circuit 300 V |
| Output Circuit 1 / Output Circuit 2 300 V | |
| Supply Circuit / Measuring Circuit 300 V | |
| Supply Circuit / Output Circuit 300 V | |
| Degree of Protection | Housing IP50 |
| Terminals IP20 | |
| Overvoltage Category | III |
| Pollution Degree | 3 |
| Short-Circuit Protective Devices | Output Circuit NC - F Type Fuses 6 A |
| Output Circuit NO - F Type Fuses 10 A | |
| Electrical Durability | AC-12 100000 cycle |
| Mechanical Durability | Nr. Operations 1000000 cycle |
| Connecting Capacity | Flexible with Ferrule 1x 0.5 ... 2.5 mm² |
| Flexible with Ferrule 2x 0.5 ... 1.5 mm² | |
| Flexible with Insulated Ferrule 1x 0.5 ... 2.5 mm² | |
| Flexible with Insulated Ferrule 2x 0.5 ... 1.5 mm² | |
| Flexible 1x 0.5 ... 2.5 mm² | |
| Flexible 2x 0.5 ... 1.5 mm² | |
| Rigid 1x 0.5 ... 4 mm² | |
| Rigid 2x 0.5 ... 2.5 mm² | |
| Tightening Torque | 0.6 ... 0.8 N·m |
| Control Circuit 0.9 N·m | |
| Main Circuit 1 N·m | |
| Wire Stripping Length | 8 mm |
| Main Circuit 10 mm | |
| Recommended Screw Driver | 0.8 x 4 |
| 4.5 | |
| Pozidriv 1 | |
| Mounting Position | 1 ... 5 |
| 1 ... 6 | |
| Mounting on DIN Rail | TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715 |
| TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715 | |
| Standards | CAN/CSA C22.2 No.14 |
| IEC/EN 63000 | |
| IEC/EN 60255-27 | |
| IEC/EN 61000-6-2 | |
| IEC/EN 61000-6-3 | |
| UL 508 | |
| Technical UL/CSA | |
| Maximum Operating Voltage UL/CSA | Output Circuit 300 V AC |
| Contact Rating UL/CSA | B300 |
| Connecting Capacity UL/CSA | Flexible 1x 18-14 AWG |
| Flexible 2x 18-16 AWG | |
| Rigid 1x 20-12 AWG | |
| Rigid 2x 20-14 AWG | |
| Tightening Torque UL/CSA | 7.08 in·lb |
| Pilot Duty UL/CSA | B300 |
| Environmental | |
| Ambient Air Temperature | Operation -25 ... +60 °C |
| Storage -40 ... +85 °C | |
| Maximum Operating Altitude Permissible | Without Derating 2000 m |
| Material Compliance | |
| Conflict Minerals Reporting Template (CMRT) | 9AKK108467A5658 |
| REACH Declaration | 1SVD981001-4501 |
| RoHS Declaration | 1SVD981001-4401 |
| SCIP | 4ba8788c-849d-4398-9b5b-a49a558758f3 Germany |
| Simplified SCIP | f0cfe18f-553d-4647-b6b6-e2f24549a7a9 Belgium |
| 2edfe2ec-ec32-439c-9eb0-0d22acd0d991 Germany | |
| 090efef3-0fe0-4c77-8546-1660c9a22189 Finland | |
| 49e236f7-62f3-4331-888c-91a0ff810cda Germany | |
| fb67750a-2ebe-4411-a05f-ee75e51c00fe Norway | |
| 2a091dc3-c6ba-4cb9-afab-0d00bc385e1a Poland | |
| e7274378-6e04-4759-83dc-d87b17cc0891 Italy | |
| a029d6cb-83be-4fd4-b5f7-e32b4504f1e2 Poland | |
| ef6aad7b-2017-4f7c-87e4-39d7d87e6a37 Poland | |
| f2c43e3d-773e-4db2-a9f9-97359ffe565e Denmark | |
| 54aae020-7711-441e-88f8-0f1cbf34bbb5 Spain | |
| ae5078f4-abee-4d3f-8e01-8478da97a3fc Germany | |
| c1a7db82-aad7-481d-932b-b641a3f35f76 Sweden | |
| 05e3b622-4ea4-49e1-975c-30b66d573bf1 Sweden | |
| ab6b2277-2b1c-4e28-b46c-5e72bf4c91de France | |
| afe38d37-5616-4cd3-ae8c-f044d1913451 France | |
| 14ff2a23-8921-4cf6-9ecf-5e2c7b257870 Hungary | |
| 2f6ca320-28dc-4ea7-8366-2c345355e4c7 Belgium | |
| c7487365-b4e9-48c9-995e-bbe6627e6175 Bulgaria | |
| d147c270-006d-4453-a677-69559269944a Portugal | |
| 5e894537-d6b1-4d81-acfc-f989190cc093 Hungary | |
| 3d37ab07-97ce-4280-93a8-96c1417067f2 Greece | |
| 8f008e53-5bc8-4762-8648-96c863018818 Netherlands | |
| 1e823c29-573f-4643-8e1d-3501d1892105 Germany | |
| 62f059e9-4f18-40e0-92f9-a176451b2ba2 Czech Republic | |
| f2013fb5-ba48-42fd-9400-eaff505f4402 Croatia | |
| 6c46ba48-192f-4acc-ab54-c55ec1540658 Estonia | |
| Toxic Substances Control Act - TSCA | 2CMT2023-006536 |
| ABB EcoSolutions | |
| ABB EcoSolutions | Yes |
| Environmental Product Declaration - EPD | 1SAC200438H0001 |
| Certificates and Declarations | |
| CQC Certificate | CQC2015010303819793 |
| cULus Certificate | cULus508_20150627-E140448 |
| Declaration of Conformity - CCC | 2020980303000198 |
| Declaration of Conformity - CE | 1SVD981005-00 |
| Declaration of Conformity - UKCA | 1SVD981005-10 |
| DNV GL Certificate | DNV_GL_TAA00000RW |
| Container Information | |
| Package Level 1 Units | box 1 piece |
| Package Level 1 Width | 97 mm |
| Package Level 1 Depth / Length | 30 mm |
| Package Level 1 Height | 109 mm |
| Package Level 1 Gross Weight | 0.148 kg |
| Package Level 1 EAN | 4013614502934 |
| External Classifications and Standards | |
| Object Classification Code | B |
| ETIM 7 | EC001447 - (Fill) level monitoring relay |
| ETIM 8 | EC001447 - (Fill) level monitoring relay |
| ETIM 9 | EC001447 - (Fill) level monitoring relay |
| eClass | V11.0 : 27371813 |
| UNSPSC | 39122331 |
| E-Number (Finland) | 2712566 |
| E-Number (Norway) | 4189433 |