View larger
GJL1201330R0010 ABB CAF6-02E Auxiliary Contact
GJL1201330R0010
1201330
ABB
1 Pcs.
Automation > Auxiliary contact block
Minicontactors B6-B7
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
Abb auxiliary contact block CAF6-02E GJL1201330R0010 mounts onto miniature contactors to deliver supplementary normally closed signal circuits for control systems. These snap-on contact blocks allow engineers to integrate complex feedback and interlocking logic into compact control enclosures.
Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Number of contacts as change-over contact: 0
- Number of contacts as normally open contact: 0
- Number of contacts as normally closed contact: 2
- Number of fault-signal switches: 0
- Rated operation current Ie at AC-15, 230 V: 4 A
- Type of electric connection: Screw connection
- Model: Clip-on
- Mounting method: Front fastening
More info
▲The CAF6-02E is an auxiliary contact for front mounting with 2 auxiliary contact and screw terminals.
Ordering
- EAN:
- 4013614148385
- Minimum Order Quantity:
- 1 piece
- Customs Tariff Number:
- 85389099
Container Information
- Package Level 1 Width:
- 115 mm
- Package Level 1 Length:
- 280 mm
- Package Level 1 Height:
- 54 mm
- Package Level 1 Gross Weight:
- 0.24 kg
- Package Level 1 EAN:
- 4013614412318
- Package Level 1 Units:
- 10 piece
Dimensions
- Product Net Width:
- 47.5mm
- Product Net Height:
- 29mm
- Product Net Depth:
- 26.5mm
- Product Net Weight:
- 0.02kg
Technical
- Rated Operational Voltage:
- Auxiliary Circuit 12 ... 240 V DC
Auxiliary Circuit 12 ... 500 V AC/DC
- Rated Frequency (f):
- Auxiliary Circuit 50 Hz
Auxiliary Circuit 60 Hz
Auxiliary Circuit DC
- Rated Impulse Withstand Voltage (Uimp):
- Auxiliary Circuit 6 kV
- Rated Insulation Voltage (Ui):
- 690 V
- Degree of Protection:
- IP20
- Connecting Capacity-Auxiliary Circuit:
- Flexible with Ferrule 1/2x 1 ... 2.5 mm²
Flexible 1/2x 1 ... 2.5 mm²
Rigid 1/2x 1 ... 4 mm²
- Tightening Torque:
- Auxiliary Circuit 0.8 ... 1.1 N·m
- Wire Stripping Length:
- Auxiliary Circuit 9 mm
- Standards:
- IEC/EN 60947-1
IEC/EN 60947-4-1
IEC/EN 60947-5-1
UL 60947-1
UL 60947-4-1
- Number of Auxiliary Contacts NO:
- 0
- Number of Main Contacts NC:
- 0
- Number of Main Contacts NO:
- 0
- Conventional Free-air Thermal Current (Ith):
- Auxiliary Circuit 6 A
- Product Name:
- Auxiliary Contact
- Suitable For:
- B6-30-01
BC6-30-01
B7-30-01
BC7-30-01
VB6-30-01
VBC6-30-01
VB7-30-01
VBC7-30-01
VB6A-30-01
VBC6A-30-01
VB7A-30-01
VBC7A-30-01
- Suitable for Product Class:
- Mini Contactors
Environmental
- Ambient Air Temperature:
- Operation -25 ... +55 °C
Storage -40 ... +80 °C
- Maximum Operating Altitude Permissible:
- 2000 m
- Resistance to Shock acc. to IEC 60068-2-27:
- 11 ms Pulse 15g
- Resistance to Vibrations acc. to IEC 60068-2-6:
- 5g / 5 ... 150 Hz
- RoHS Status:
- Following EU Directive 2002/95/EC August 18, 2005 and amendment
Technical UL/CSA
- Maximum Operating Voltage UL/CSA:
- Auxiliary Circuit 600 V AC/DC
- Connecting Capacity Auxiliary Circuit UL/CSA:
- Stranded 1/2x 22 ... 10 AWG
- Tightening Torque UL/CSA:
- Auxiliary Circuit 7 in·lb
- Contact Rating UL/CSA:
- A600
Certificates and Declarations (Document Number)
- CCC Certificate:
- 1SAA938000-3803
- cUL Certificate:
- cUL_E48139
- Declaration of Conformity - CE:
- 1SAD938510-0001
- EAC Certificate:
- 1SAA938002-2701
- GL Certificate:
- 1SAA938000-0403
- RMRS Certificate:
- 1SAA938001-0703
- RoHS Information:
- 1SAA938004-4401
- UL Certificate:
- UL_E48139
Classifications
- Object Classification Code:
- K
- eClass:
- 7.0 27371302
- UNSPSC:
- 39121500