Request QuoteProduct Overview
An ABB GJL1213003R1106 BC6-30-10-F-16 mini contactor is designed for safe and efficient control of auxiliary circuits and small motors in confined automation spaces. Miniature contactors offer dependable performance where standard control components are too large.
Specific pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Minimum Order Quantity: 1 piece
- Customs Tariff Number: 85365080
- EPLAN Data: 9AAC201036_EPLAN
- Data Sheet, Technical Information: 1SBC100214C0202
- Instructions and Manuals: 2CDC102047M6801
- CAD Dimensional Drawing: 2CDC001079B0201
- Product Net Width: 52.5 mm
- Product Net Depth / Length: 46.7 mm
- Product Net Height: 57.5 mm
- Product Net Weight: 0.17 kg
- Dimension Diagram: GJL1200437F0001
- Number of Main Contacts NO: 3
- Number of Main Contacts NC: 0
- Number of Auxiliary Contacts NO: 1
- Number of Auxiliary Contacts NC: 0
- Number of Poles: 3P
More info
▲| Ordering | |
|---|---|
| Minimum Order Quantity | 1 piece |
| Customs Tariff Number | 85365080 |
| Popular Downloads | |
| EPLAN Data | 9AAC201036_EPLAN |
| Data Sheet, Technical Information | 1SBC100214C0202 |
| Instructions and Manuals | 2CDC102047M6801 |
| CAD Dimensional Drawing | 2CDC001079B0201 |
| Dimensions | |
| Product Net Width | 52.5 mm |
| Product Net Depth / Length | 46.7 mm |
| Product Net Height | 57.5 mm |
| Product Net Weight | 0.17 kg |
| Dimension Diagram | GJL1200437F0001 |
| Technical | |
| Number of Main Contacts NO | 3 |
| Number of Main Contacts NC | 0 |
| Number of Auxiliary Contacts NO | 1 |
| Number of Auxiliary Contacts NC | 0 |
| Number of Poles | 3P |
| Standards | IEC/EN 60947-1 |
| IEC/EN 60947-4-1 | |
| IEC/EN 60947-5-1 | |
| UL 60947-1 | |
| UL 60947-4-1 | |
| IEC 60335-2-40 A2L | |
| Rated Operational Voltage | Auxiliary Circuit 690 V AC |
| Auxiliary Circuit 250 V DC | |
| Main Circuit 690 V AC | |
| Main Circuit 220 V DC | |
| Rated Frequency (f) | Control Circuit DC |
| Main Circuit 50 Hz | |
| Main Circuit 60 Hz | |
| Main Circuit DC | |
| Conventional Free-air Thermal Current (Ith) | Main Circuit 20 A |
| Rated Operational Current AC-1 (Ie) | (220 / 240 V) 40 °C 20 A |
| (220 / 240 V) 55 °C 16 A | |
| (380 / 440 V) 40 °C 20 A | |
| (380 / 440 V) 55 °C 16 A | |
| (690 V) 40 °C 6 A | |
| (690 V) 55 °C 6 A | |
| Rated Operational Current AC-3 (Ie) | (230 V) 55°C 9 A |
| (400 V) 55 °C 9 A | |
| (500 V) 55 °C 6.5 A | |
| (690 V) NO 55°C 3.5 A | |
| Rated Operational Current AC-15 (Ie) | (24 V) 4 A |
| (120 V) 4 A | |
| (500 V) 2 A | |
| (220 / 240 V) 4 A | |
| (380 / 400 V) 3 A | |
| Rated Operational Current DC-13 (Ie) | (24 V) 2.5 A |
| (110 V) 0.7 A | |
| (220 / 240 V) 0.4 A | |
| Rated Operational Power AC-3 (Pe) | (230 V) Three Phase 2.2 kW |
| (400 V) Three Phase 4 kW | |
| (500 V) Three Phase 4 kW | |
| (690 V) Three Phase, NO 3 kW | |
| Rated Breaking Capacity AC-3 | 8 x Ie / AC-3 |
| Rated Making Capacity AC-3 | 10 x Ie / AC-3 |
| Rated Short-time Withstand Current Low Voltage (Icw) | at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 64 A |
| Rated Insulation Voltage (Ui) | 690 V |
| acc. to UL/CSA 600 V | |
| Rated Impulse Withstand Voltage (Uimp) | Auxiliary Circuit 6 kV |
| Main Circuit 6 kV | |
| Maximum Electrical Switching Frequency | (AC-1) 300 cycles per hour |
| (AC-15) 600 cycles per hour | |
| (AC-3) 600 cycles per hour | |
| (DC-1) 600 cycles per hour | |
| (DC-13) 600 cycles per hour | |
| (DC-3) 600 cycles per hour | |
| Mechanical Durability | Nr. Operations 10000000 cycle |
| Minimum Switching Capacity | Auxiliary Circuit 17 V |
| Auxiliary Circuit 5 mA | |
| Coil Operating Limits | (acc. to IEC 60947-4-1) for DC supply 0.85 ... 1.1 x Uc (at θ ≤ 55 °C) |
| Rated Control Circuit Voltage (Uc) | 48 V DC |
| Coil Consumption | Average Holding Value DC 3.5 W |
| Average Pull-in Value DC 3.5 W | |
| Power Loss | at Rated Operating Conditions AC-1 per Pole 1 W |
| Mounting on DIN Rail | TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715 |
| TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715 | |
| Degree of Protection | Auxiliary Circuit Terminals IP20 |
| Control Circuit Terminals IP20 | |
| Main Circuit Terminals IP20 | |
| Terminal Type | Flat-Pin Connections |
| Mini Contactor Type | Mini Contactor |
| Product Name | Mini Contactor |
| Technical UL/CSA | |
| Maximum Operating Voltage UL/CSA | Main Circuit 600 V AC |
| General Use Rating UL/CSA | (300 V AC) 12 A |
| Horsepower Rating UL/CSA | (115 V AC) Single Phase 0.25 Hp |
| (200 V AC) Three Phase 1 Hp | |
| (220 ... 240 V AC) Three Phase 2 Hp | |
| (230 V AC) Single Phase 0.5 Hp | |
| (440 ... 480 V AC) Three Phase 3 Hp | |
| (550 ... 600 V AC) Three Phase 1 Hp | |
| Contact Rating UL/CSA | A600 |
| Full Load Amps Motor Use | (115 V AC) Single Phase 5.8 A |
| (200 V AC) Three Phase 4.8 A | |
| (220 ... 240 V AC) Three Phase 6.8 A | |
| (230 V AC) Single Phase 4.9 A | |
| (440 ... 480 V AC) Three Phase 4.8 A | |
| (550 ... 600 V AC) Three Phase 1.7 A | |
| Environmental | |
| Ambient Air Temperature | Operation -25 ... +55 °C |
| Storage -40 ... +80 °C | |
| Maximum Operating Altitude Permissible | 2000 m |
| Resistance to Shock acc. to IEC 60068-2-27 | 11 ms Pulse 15g |
| Resistance to Vibrations | 5g 5 ... 150 Hz |
| Material Compliance | |
| Conflict Minerals Reporting Template (CMRT) | 9AKK108467A5658 |
| REACH Declaration | 2CMT2021-006202 |
| RoHS Declaration | 2CMT2021-006277 |
| RoHS Information | Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019 |
| Toxic Substances Control Act - TSCA | 2CMT2023-006525 |
| WEEE B2C / B2B | Business To Business |
| WEEE Category | 5. Small Equipment (No External Dimension More Than 50 cm) |
| Certificates and Declarations | |
| A2L Certificate – IEC | 1SAA938000-4601 |
| BV Certificate | 1SAA920000-0204 |
| CB Certificate | 1SAA938000-2002 |
| CQC Certificate | CQC2003010304064033 |
| cURus Certificate | cUL_E191658 |
| Declaration of Conformity - CCC | 2020980304001854 |
| Declaration of Conformity - CE | 1SAD101100-3101 |
| Declaration of Conformity - UKCA | 1SAD201100-3101 |
| DNV GL Certificate | 1SAA938000-0306 |
| EAC Certificate | 1SAA920000-2702 |
| KC Certificate | 1SAA938000-1501 |
| LR Certificate | 1SAA938000-0504 |
| RMRS Certificate | 1SAA938000-0704 |
| Container Information | |
| Package Level 1 Units | carton 10 piece |
| Package Level 1 Width | 115 mm |
| Package Level 1 Depth / Length | 280 mm |
| Package Level 1 Height | 54 mm |
| Package Level 1 Gross Weight | 1.77 kg |
| Package Level 1 EAN | 4013614414954 |
| External Classifications and Standards | |
| Object Classification Code | Q |
| ETIM 7 | EC000066 - Power contactor, AC switching |
| ETIM 8 | EC000066 - Power contactor, AC switching |
| ETIM 9 | EC000066 - Power contactor, AC switching |
| eClass | V11.0 : 27371003 |
| UNSPSC | 39121529 |