ABB 1SBL407001R1311 1SBL407001R1311 ABB AF96-30-11-13 100-250V50/60HZ-DC Contactor View larger
Images are for illustrative purposes only. Please refer to data sheet for details

1SBL407001R1311 ABB AF96-30-11-13 100-250V50/60HZ-DC Contactor

1SBL407001R1311

407001

ABB

1 Pcs.

AF96-30-11-13 100-250V50/60HZ-DC Contactor AF96-30-11-13 CONT. 3P B. 100-250VAC-DC

Automation > Power contactor, AC switching
AF contactors 40A to 100A

Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.

Request a Quote

Pricing and availability are confirmed for each enquiry. Add your required quantity to begin.

No account, online checkout or payment is required.

More info

Ordering
Minimum Order Quantity1 piece
Customs Tariff Number85364900
Popular Downloads
EPLAN Data9AAC175976_EPLAN
Data Sheet, Technical Information1SBC100214C0202
Instructions and Manuals1SBC101036M6801
Instructions and Manuals (Part 2)1SAC200017M0002
CAD Dimensional Drawing2CDC001079B0201
Dimensions
Product Net Width82 mm
Product Net Depth / Length116 mm
Product Net Height125.5 mm
Product Net Weight1.21 kg
Technical
Number of Main Contacts NO3
Number of Main Contacts NC0
Number of Auxiliary Contacts NO1
Number of Auxiliary Contacts NC1
Number of Poles3P
StandardsIEC/EN 60947-1, IEC/EN 60947-4-1, UL 60335-2-40 LZGH2 A2L, UL 60947-1, UL 60947-4-1, CSA C22.2 No. 60335-2-40 LZGH2 A2L, CSA C22.2 No. 60947-1:22, CSA C22.2 No. 60947-4-1:22
Rated Operational VoltageAuxiliary Circuit 690 V
Main Circuit 1000 V
Rated Frequency (f)Auxiliary Circuit 50 / 60 Hz
Control Circuit 50 / 60 Hz
Main Circuit 50 / 60 Hz
Conventional Free-air Thermal Current (Ith)acc. to IEC 60947-4-1, Open Contactors Θ = 40 °C 130 A
acc. to IEC 60947-5-1, Θ = 40 °C 16 A
Rated Operational Current AC-1 (Ie)(690 V) 40 °C 130 A
(690 V) 60 °C 105 A
(690 V) 70 °C 90 A
Rated Operational Current AC-3 (Ie)(415 V) 60 °C 96 A
(440 V) 60 °C 96 A
(500 V) 60 °C 80 A
(690 V) 60 °C 57 A
(1000 V) 60 °C 30 A
(380 / 400 V) 60 °C 105 A
(220 / 230 / 240 V) 60 °C 105 A
Rated Operational Current AC-3e (Ie)(415 V) 60 °C 96 A
(440 V) 60 °C 96 A
(500 V) 60 °C 80 A
(690 V) 60 °C 57 A
(380 / 400 V) 60 °C 105 A
(220 / 230 / 240 V) 60 °C 105 A
Rated Operational Current AC-15 (Ie)(500 V) 2 A
(690 V) 2 A
(24 / 127 V) 6 A
(220 / 240 V) 4 A
(400 / 440 V) 3 A
Rated Operational Current DC-1 (Ie)(110 V) 2 Poles in Series, 40 °C 130 A
(110 V) 2 Poles in Series, 60 °C 105 A
(110 V) 2 Poles in Series, 70 °C 90 A
(110 V) 3 Poles in Series, 40 °C 130 A
(110 V) 3 Poles in Series, 60 °C 105 A
(110 V) 3 Poles in Series, 70 °C 90 A
(220 V) 3 Poles in Series, 40 °C 125 A
(220 V) 3 Poles in Series, 60 °C 105 A
(220 V) 3 Poles in Series, 70 °C 90 A
(72 V) 1-Pole, 40 °C 130 A
(72 V) 1-Pole, 60 °C 105 A
(72 V) 1-Pole, 70 °C 90 A
(72 V) 2 Poles in Series, 40 °C 130 A
(72 V) 2 Poles in Series, 60 °C 105 A
(72 V) 2 Poles in Series, 70 °C 90 A
(72 V) 3 Poles in Series, 40 °C 130 A
(72 V) 3 Poles in Series, 60 °C 105 A
(72 V) 3 Poles in Series, 70 °C 90 A
Rated Operational Current DC-3 (Ie)(110 V) 2 Poles in Series, 40 °C 130 A
(110 V) 2 Poles in Series, 60 °C 105 A
(110 V) 2 Poles in Series, 70 °C 90 A
(110 V) 3 Poles in Series, 40 °C 130 A
(110 V) 3 Poles in Series, 60 °C 105 A
(110 V) 3 Poles in Series, 70 °C 90 A
(220 V) 3 Poles in Series, 40 °C 130 A
(220 V) 3 Poles in Series, 60 °C 105 A
(220 V) 3 Poles in Series, 70 °C 90 A
(72 V) 1-Pole, 40 °C 130 A
(72 V) 1-Pole, 60 °C 105 A
(72 V) 1-Pole, 70 °C 90 A
(72 V) 2 Poles in Series, 40 °C 130 A
(72 V) 2 Poles in Series, 60 °C 105 A
(72 V) 2 Poles in Series, 70 °C 90 A
(72 V) 3 Poles in Series, 40 °C 130 A
(72 V) 3 Poles in Series, 60 °C 105 A
(72 V) 3 Poles in Series, 70 °C 90 A
Rated Operational Current DC-5 (Ie)(110 V) 2 Poles in Series, 40 °C 130 A
(110 V) 2 Poles in Series, 60 °C 105 A
(110 V) 2 Poles in Series, 70 °C 90 A
(110 V) 3 Poles in Series, 40 °C 130 A
(110 V) 3 Poles in Series, 60 °C 105 A
(110 V) 3 Poles in Series, 70 °C 90 A
(220 V) 3 Poles in Series, 40 °C 130 A
(220 V) 3 Poles in Series, 60 °C 105 A
(220 V) 3 Poles in Series, 70 °C 90 A
(72 V) 1-Pole, 40 °C 130 A
(72 V) 1-Pole, 60 °C 105 A
(72 V) 1-Pole, 70 °C 90 A
(72 V) 2 Poles in Series, 40 °C 130 A
(72 V) 2 Poles in Series, 60 °C 105 A
(72 V) 2 Poles in Series, 70 °C 90 A
(72 V) 3 Poles in Series, 40 °C 130 A
(72 V) 3 Poles in Series, 60 °C 105 A
(72 V) 3 Poles in Series, 70 °C 90 A
Rated Operational Current DC-13 (Ie)(24 V) 6 A / 144 W
(48 V) 2.8 A / 134 W
(72 V) 1 A / 72 W
(110 V) 1.1 A / 121 W
(125 V) 0.55 A / 69 W
(220 V) 0.27 A / 60 W
(250 V) 0.27 A / 68 W
(400 V) 0.15 A / 60 W
(500 V) 0.13 A / 65 W
(600 V) 0.1 A / 60 W
Rated Operational Power AC-3 (Pe)(415 V) 55 kW
(440 V) 55 kW
(500 V) 55 kW
(690 V) 55 kW
(1000 V) 40 kW
(380 / 400 V) 45 kW
(380 / 400 V) 55 kW
(220 / 230 / 240 V) 25 kW
(220 / 230 / 240 V) 30 kW
Rated Operational Power AC-3e (Pe)(415 V) 55 kW
(440 V) 55 kW
(500 V) 55 kW
(690 V) 55 kW
(380 / 400 V) 45 kW
(380 / 400 V) 55 kW
(220 / 230 / 240 V) 25 kW
(220 / 230 / 240 V) 30 kW
Rated Short-time Withstand Current Low Voltage (Icw)at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 840 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 140 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 300 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 1200 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 450 A
for 0.1 s 140 A
for 1 s 100 A
Maximum Breaking Capacitycos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 1150 A
cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 750 A
Rated Insulation Voltage (Ui)acc. to IEC 60947-4-1 1000 V
acc. to IEC 60947-5-1 690 V
acc. to UL/CSA 600 V
Rated Impulse Withstand Voltage (Uimp)8 kV
Maximum Electrical Switching Frequency(AC-1) 600 cycles per hour
(AC-15) 1200 cycles per hour
(AC-2 / AC-4) 150 cycles per hour
(AC-3) 1200 cycles per hour
(DC-13) 900 cycles per hour
Maximum Mechanical Switching Frequency3600 cycles per hour
Rated Control Circuit Voltage (Uc)50 Hz 100 ... 250 V
60 Hz 100 ... 250 V
DC Operation 100 ... 250 V
Coil ConsumptionAverage Holding Value 50 / 60 Hz 4 V·A
Average Holding Value 50 Hz 4 V·A
Average Holding Value 60 Hz 4 V·A
Average Holding Value DC 2 W
Average Holding Value, from Warm State 2 W
Power Lossat 6 A per Pole 0.1 W
at Rated Operating Conditions AC-1 per Pole 8.2 W
at Rated Operating Conditions AC-3 per Pole 4.5 W
Operate TimeBetween Coil De-energization and NC Contact Closing 19 ... 105 ms
Between Coil De-energization and NO Contact Opening 17 ... 100 ms
Between Coil Energization and NC Contact Opening 38 ... 95 ms
Between Coil Energization and NO Contact Closing 42 ... 100 ms
Mounting on DIN RailTH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715
Mounting by Screws (not supplied) 2 x M4 or 2 x M6 Screws Placed Diagonally
Connecting Capacity Main CircuitFlexible with Ferrule 1/2x 6 ... 50 mm²
Flexible with Insulated Ferrule 1/2x 6 ... 50 mm²
Rigid Stranded 1x 6 ... 70 mm²
Rigid Stranded 2x 6 ... 50 mm²
Connecting Capacity Auxiliary CircuitFlexible with Ferrule 1/2x 0.75 ... 2.5 mm²
Flexible with Insulated Ferrule 2x 0.75 ... 1.5 mm²
Flexible with Insulated Ferrule 1x 0.75 ... 2.5 mm²
Rigid 1/2x 1 ... 2.5 mm²
Connecting Capacity Control CircuitFlexible with Ferrule 1/2x 0.75 ... 2.5 mm²
Flexible with Insulated Ferrule 1x 0.75 ... 2.5 mm²
Flexible with Insulated Ferrule 2x 0.75 ... 1.5 mm²
Rigid 1/2x 1 ... 2.5 mm²
Wire Stripping LengthAuxiliary Circuit 10 mm
Control Circuit 10 mm
Main Circuit 17 mm
Degree of Protectionacc. to IEC 60529, IEC 60947-1, EN 60529 Auxiliary Terminals IP20
acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20
acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP10
Recommended Screw DriverPozidriv PZ
Tightening TorqueAuxiliary Circuit 1.2 N·m
Control Circuit 1.2 N·m
Main Circuit 6 N·m
Terminal TypeScrew Terminals
Product NameBlock Contactor
Technical UL/CSA
Maximum Operating Voltage UL/CSAMain Circuit 600 V
General Use Rating UL/CSA(600 V AC) 115 A
Horsepower Rating UL/CSA(120 V AC) Single Phase 7-1/2 hp
(200 ... 208 V AC) Three Phase 30 hp
(220 ... 240 V AC) Three Phase 40 hp
(240 V AC) Single Phase 20 hp
(440 ... 480 V AC) Three Phase 75 hp
(550 ... 600 V AC) Three Phase 75 hp
Connecting Capacity Main Circuit UL/CSARigid Stranded 1/2x 6-1 AWG
Tightening Torque UL/CSAAuxiliary Circuit 11 in·lb
Control Circuit 11 in·lb
Main Circuit 53 in·lb
Full Load Amps Motor Use(120 V AC) Single Phase 80 A
(200 ... 208 V AC) Three Phase 92 A
(220 ... 240 V AC) Three Phase 80 A
(240 V AC) Single Phase 88 A
(440 ... 480 V AC) Three Phase 77 A
(550 ... 600 V AC) Three Phase 77 A
Environmental
Ambient Air TemperatureClose to Contactor Fitted with Thermal O/L Relay -40 ... 70 °C
Close to Contactor without Thermal O/L Relay -40 ... 70 °C
Close to Contactor for Storage -60 ... +80 °C
Climatic WithstandCategory B according to IEC 60947-1 Annex Q
Maximum Operating Altitude PermissibleWithout Derating 3000 m
Resistance to Shock acc. to IEC 60068-2-27Closed, Shock Direction: A 25 g
Closed, Shock Direction: B1 25 g
Closed, Shock Direction: B2 15 g
Closed, Shock Direction: C1 25 g
Closed, Shock Direction: C2 25 g
Open, Shock Direction: B1 5 g
Resistance to Vibrations3g Closed Position & 3g Open Position 5 ... 300 Hz
Pollution Degree3
Material Compliance
Conflict Minerals Reporting Template (CMRT)9AKK108467A5658
REACH Declaration2CMT2021-006202
RoHS Declaration2CMT2021-006277
RoHS InformationFollowing EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
SCIPb3660a46-c54b-4df0-990c-d0bb531104cd China
Simplified SCIPd6888301-88c2-44cd-bd93-b37a5506a8c7 Hungary
6b74900d-1ba3-4e68-9e89-88dbecb7b197 Poland
1299a63f-cccc-448c-b1c2-577db243066f Netherlands
83b5261b-b804-45be-8ebb-7b66c90d4601 Estonia
66ada6e7-1ab0-4a2b-bfb0-13118a811807 Greece
ab93c083-b268-4f40-8e0a-ea97373f2155 Poland
7d5cc3a9-430d-468f-b35f-2467084ca0b5 Finland
f22fa7e6-565e-4d1d-832e-ced12a336967 Norway
2f336eeb-bc1f-43f5-a63a-19b15b86a45e Spain
82881e21-358f-433a-9283-9cac200d858b Germany
d38ff649-fb62-443b-a76f-fb47b3304d19 Denmark
00a7c319-5c0b-4c75-9857-71669b252c84 Germany
7b6eb334-38f3-4493-87c4-67c91d4588c6 Belgium
d53b93b7-6a24-43f0-8d21-341baecacaf9 Croatia
0f68b96c-6bbc-4926-965b-931a178097e4 Portugal
b6c2b666-a504-4c52-84de-2d8687be582d Bulgaria
180bea10-5857-4f2a-8e78-b55e94c73a1b Sweden
a19e10ea-2ce9-4060-aedc-dbabb3bea884 Germany
2dc2763a-404a-4026-a6a2-bf10ba6cca7e France
46eb700a-2dd0-45ec-95cb-a002d5d4989a Poland
f1edf5f2-9ef2-4c06-b6ec-541d416afc9a Hungary
fe305d8b-2bd8-43f6-89c0-0b3212385d53 Belgium
df906006-5675-451c-8a27-3e33e30b7915 France
05421bf0-0aa8-47a7-aa3c-f8292b067f57 Sweden
f5444f58-a9ed-4ff2-b6a5-473cfa676c4f Germany
68c2eecf-5385-4fb1-aede-bd1c11be91c9 Czech Republic
9d81ed5a-7342-41e2-a2e9-4d2a9277e248 Germany
Toxic Substances Control Act - TSCA2CMT2023-006525
WEEE B2C / B2BBusiness To Business
WEEE Category5. Small Equipment (No External Dimension More Than 50 cm)
ABB EcoSolutions
ABB EcoSolutionsYes
End Of Life Disassembling Instructions1SBC101081M6801
Environmental Product Declaration - EPD1SBD250584E1000
Certificates and Declarations
A2L Certificate – UL9AKK108469A4890
9AKK108469A4892
ABS CertificateABS_20-2060694-PDA
BV CertificateBV_2634H36994A
CB CertificateCB_SE-116522
CCC CertificateCCC_2024010304656667
Declaration of Conformity - CCC2020980304001255
Declaration of Conformity - CE1SBD250000U1000
Declaration of Conformity - UKCA1SBD250031U1000
DNV CertificateDNV_TAE00001AF-4
KC CertificateKC_HW02016-15011C
LR CertificateLRS_LR23403517TA-02
RINA CertificateRINA_ELE084013XG
RMRS CertificateRMRS_1802705280
UL CertificateUL-US-L312527-1141-10303102-19
UL-CA-L312527-4141-10303102-19
UL Listing CardUL_E312527
Container Information
Package Level 1 Unitsbox 1 piece
Package Level 1 Width150 mm
Package Level 1 Depth / Length150 mm
Package Level 1 Height103 mm
Package Level 1 Gross Weight1.33 kg
Package Level 1 EAN3471523133334
Package Level 2 Unitsbox 8 piece
Package Level 2 Width250 mm
Package Level 2 Depth / Length300 mm
Package Level 2 Height300 mm
Package Level 2 Gross Weight10.64 kg
External Classifications and Standards
Object Classification CodeQ
ETIM 7EC000066 - Power contactor, AC switching
ETIM 8EC000066 - Power contactor, AC switching
ETIM 9EC000066 - Power contactor, AC switching
eClassV11.0 : 27371003
UNSPSC39121529
IDEA Granular Category Code (IGCC)4758 >> Iec Contactors
E-Number (Finland)3707142

ETIM for 1SBL407001R1311 Low-voltage industrial controls and switchgear (EC000066)
Feature Name Feature Value
Rated control supply voltage AC 50 Hz (EF003978) 100 V
Rated control supply voltage AC 60 Hz (EF003979) 100 V
Rated control supply voltage DC (EF003980) 100 V
Voltage type for actuating (EF008242) AC/DC
Rated operation current Ie at AC-1, 400 V (EF001393) 130 A
Rated operation current Ie at AC-3, 400 V (EF001392) 105 A
Rated operation power at AC-3, 400 V (EF001364) 45 kW
Modular version (EF001126) No
Number of auxiliary contacts as normally open contact (EF001376) 1
Number of auxiliary contacts as normally closed contact (EF001377) 1
Type of electrical connection of main circuit (EF006819) Screw connection
Number of normally closed contacts as main contact (EF001375) 0
Number of normally open contacts as main contact (EF001374) 3

Product Datasheet

Electrica Online Product Datasheet Prepared from the current product description, catalog data and structured technical attributes.