Automation > Power contactor, AC switching
"A" SECRLP
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
1SFL637001R6811 ABB AF750-30-11 24-60V DC Contactor is a heavy-duty electromechanical switching device utilized to control high-power electrical loads, industrial motors, and major distribution circuits. Contactors provide reliable remote switching capabilities for demanding power applications, utilizing electromagnetic coils to open and close primary contacts safely within electrical panels.
Pricing, availability, and lead time are confirmed per enquiry through an RFQ.
- Rated control supply voltage DC (EF003980): 24 V
- Voltage type for actuating (EF008242): DC
- Rated operation current Ie at AC-1, 400 V (EF001393): 1050 A
- Rated operation current Ie at AC-3, 400 V (EF001392): 750 A
- Rated operation power at AC-3, 400 V (EF001364): 400 kW
- Rated operation power NEMA (EF011960): 223.7100 kW
- Modular version (EF001126): No
- Type of electrical connection of main circuit (EF006819): Screw connection
- Number of normally open contacts as main contact (EF001374): 3
More info
▲A 3-phase Contactor suitable for various applications such as Motor starting, Isolation, By-pass and Distribution application up to max 1000 V. Operated with wide control voltage range 24-60 V, DC
Ordering
- EAN:
- 7320500220399
- Minimum Order Quantity:
- 1 piece
- Customs Tariff Number:
- 85364900
Dimensions
- Product Net Width:
- 210.0mm
- Product Net Depth:
- 242.0mm
- Product Net Height:
- 283.0mm
- Product Net Weight:
- 15.000kg
Container Information
- Package Level 1 Units:
- 1 piece
- Package Level 1 Width:
- 290 mm
- Package Level 1 Length:
- 270 mm
- Package Level 1 Height:
- 350 mm
- Package Level 1 Gross Weight:
- 15 kg
- Package Level 1 EAN:
- 7320500220399
Technical
- Number of Main Contacts NO:
- 3
- Number of Main Contacts NC:
- 0
- Number of Auxiliary Contacts NO:
- 1
- Number of Auxiliary Contacts NC:
- 1
- Rated Operational Voltage:
- Main Circuit 1000 V
- Rated Frequency (f):
- Main Circuit 50 Hz
Main Circuit 60 Hz
- Conventional Free-air Thermal Current (Ith):
- acc. to IEC 60947-4-1, Open Contactors q = 40 °C 1050 A
- Rated Operational Current AC-1 (Ie):
- (690 V) 55 °C 875 A
(690 V) 40 °C 1050 A
(1000 V) 40 °C 1000 A
(1000 V) 55 °C 875 A
(690 V) 70 °C 720 A
(1000 V) 70 °C 720 A
- Rated Operational Current AC-3 (Ie):
- (1000 V) 55 °C 300 A
(690 V) 55 °C 650 A
(415 V) 55 °C 750 A
(220 / 230 / 240 V) 55 °C 750 A
(440 V) 55 °C 750 A
(380 / 400 V) 55 °C 750 A
(500 V) 55 °C 750 A
- Rated Operational Power AC-3 (Pe):
- (500 V) 520 kW
(690 V) 600 kW
(220 / 230 / 240 V) 220 kW
(380 / 400 V) 400 kW
(440 V) 450 kW
(415 V) 425 kW
- Rated Breaking Capacity AC-3 acc. to IEC 60947-4-1:
- 8 x Ie AC-3
- Rated Making Capacity AC-3 acc. to IEC 60947-4-1:
- 10 x Ie AC-3
- Short-Circuit Protective Devices:
- gG Type Fuses 1000 A
- Rated Short-time Withstand Current (Icw):
- at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 6400 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 1300 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 4500 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 7000 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 3500 A
- Maximum Breaking Capacity:
- cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 7500 A
cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 7000 A
- Maximum Electrical Switching Frequency:
- AC-3 300 cycles per hour
AC-1 300 cycles per hour
AC-2 / AC-4 60 cycles per hour
- Rated Operational Current DC-1 (Ie):
- (850 V) 3 Poles in Series, 40 °C 1050 A
(600 V) 3 Poles in Series, 40 °C 1050 A
(110 V) 1-Pole, 40 °C 1050 A
(110 V) 2 Poles in Series, 40 °C 1050 A
(220 V) 3 Poles in Series, 40 °C 1050 A
- Rated Operational Current DC-3 (Ie):
- (850 V) 3 Poles in Series, 40 °C 1050 A
(600 V) 3 Poles in Series, 40 °C 1050 A
(110 V) 1-Pole, 40 °C 1050 A
(110 V) 2 Poles in Series, 40 °C 1050 A
(220 V) 3 Poles in Series, 40 °C 1050 A
- Rated Operational Current DC-5 (Ie):
- (850 V) 3 Poles in Series, 40 °C 1050 A
(600 V) 3 Poles in Series, 40 °C 1050 A
(110 V) 1-Pole, 40 °C 1050 A
(110 V) 2 Poles in Series, 40 °C 1050 A
(220 V) 3 Poles in Series, 40 °C 1050 A
- Rated Insulation Voltage (Ui):
- acc. to UL/CSA 600 V
acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 1000 V
- Rated Impulse Withstand Voltage (Uimp):
- Main Circuit 8 kV
- Mechanical Durability:
- 3 million
- Maximum Mechanical Switching Frequency:
- 300 cycles per hour
- Coil Operating Limits:
- (acc. to IEC 60947-4-1)0.85 x Uc Min. ... 1.1 x Uc Max. (at θ ≤ 70 °C) °C
- Rated Control Circuit Voltage (Uc):
- DC Operation 24 … 60 V
- Coil Consumption:
- Pull-in at Max. Rated Control Circuit Voltage 60 Hz 780 V·A
Holding at Max. Rated Control Circuit Voltage DC 5.5 V·A
Holding at Max. Rated Control Circuit Voltage 50 Hz 12 V·A
Pull-in at Max. Rated Control Circuit Voltage DC 785 V·A
Pull-in at Max. Rated Control Circuit Voltage 50 Hz 780 V·A
Holding at Max. Rated Control Circuit Voltage 60 Hz 12 V·A
- Operate Time:
- Between Coil Energization and NO Contact Closing 50 ... 120 ms
Between Coil De-energization and NO Contact Opening 53 ... 73 ms
Between Coil De-energization and NC Contact Closing 50 ... 70 ms
Between Coil Energization and NC Contact Opening 45 ... 115 ms
- Connecting Capacity-Main Circuit:
- Rigid Al-Cable 300 mm²
Bar 52 mm
Rigid Cu-Cable 300 mm²
- Connecting Capacity-Auxiliary Circuit:
- Solid 1x1…4 mm²
Flexible with Insulated Ferrule 2x0.75…2.5 mm²
Stranded 2x1…4 mm²
Flexible 2x0.75…2.5 mm²
Flexible with Ferrule 2x0.75…2.5 mm²
- Degree of Protection:
- acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20
acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP00
- Terminal Type:
- Main Circuit: Bars
Environmental
- Ambient Air Temperature:
- Close to Contactor Fitted with Thermal O/L Relay (0.85 ... 1.1 Uc) -25…+50 °C
Close to Contactor without Thermal O/L Relay (0.85 ... 1.1 Uc) -40…+70 °C
Close to Contactor for Storage -40…+70 °C
- Maximum Operating Altitude Permissible:
- 3000 m
- Resistance to Shock acc. to IEC 60068-2-27:
- Shock Direction: A 5 g
Shock Direction: C2 5 g
Shock Direction: C1 5 g
Shock Direction: B2 5 g
Shock Direction: B1 5 g
- RoHS Status:
- Following EU Directive 2002/95/EC August 18, 2005 and amendment
Technical UL/CSA
- Maximum Operating Voltage UL/CSA:
- Main Circuit 600 V
- General Use Rating UL/CSA:
- (600 V AC) 900 A
- Horsepower Rating UL/CSA:
- (208 V AC) Three Phase 250 Hp
(440 ... 480 V AC) Three Phase 600 Hp
(550 ... 600 V AC) Three Phase 700 Hp
(220 ... 240 V AC) Three Phase 300 Hp
(200 V AC) Three Phase 250 Hp
Certificates and Declarations (Document Number)
- BV Certificate:
- 11727/C0 BV
- CB Certificate:
- SE-69481
- CCC Certificate:
- CQC_2007010304256684
- CSA Certificate:
- 306712-1
- Declaration of Conformity - CE:
- 1SFA1-65
- DNV Certificate:
- DNV_E-10966
- GL Certificate:
- GL_42988-02HH
- LOVAG Certificate:
- SE-0151293
- LR Certificate:
- LR_13_20009
- RINA Certificate:
- ELE060313XG/002
- RoHS Information:
- 1SFC101055D0202
Classifications
- E-nummer:
- 3228362
- ETIM 5:
- EC000066 - Magnet contactor, AC-switching
- UNSPSC:
- 39121529