AF400-30-11 CONT. 3P 400A BOB. 200-500V
Automation > Power contactor, AC switching
"A" SECRLP
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
Handling massive electrical currents in heavy industrial plants, this ABB contactor serves as a high-capacity switching device for large motors and primary power lines. Panel designers deploy these units to ensure failsafe operation.
Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Minimum Order Quantity: 1 piece
- Customs Tariff Number: 85364900
- EPLAN Data: 9AAC200764_EPLAN
- Data Sheet, Technical Information: 1SBC100214C0202
- Data Sheet, Technical Information (Part 2): 1SAC200017M0002
- Instructions and Manuals: 1SFC380023-en
- CAD Dimensional Drawing: 2CDC001079B0201
- Product Net Width: 186 mm
- Product Net Depth / Length: 216 mm
- Product Net Height: 278 mm
- Product Net Weight: 10.6 kg
- Dimension Diagram: 53540919-59
- Number of Main Contacts NO: 3
- Number of Main Contacts NC: 0
- Number of Auxiliary Contacts NO: 1
- Number of Auxiliary Contacts NC: 1
More info
▲| Ordering | |
|---|---|
| Minimum Order Quantity | 1 piece |
| Customs Tariff Number | 85364900 |
| Popular Downloads | |
| EPLAN Data | 9AAC200764_EPLAN |
| Data Sheet, Technical Information | 1SBC100214C0202 |
| Data Sheet, Technical Information (Part 2) | 1SAC200017M0002 |
| Instructions and Manuals | 1SFC380023-en |
| CAD Dimensional Drawing | 2CDC001079B0201 |
| Dimensions | |
| Product Net Width | 186 mm |
| Product Net Depth / Length | 216 mm |
| Product Net Height | 278 mm |
| Product Net Weight | 10.6 kg |
| Dimension Diagram | 53540919-59 |
| Technical | |
| Number of Main Contacts NO | 3 |
| Number of Main Contacts NC | 0 |
| Number of Auxiliary Contacts NO | 1 |
| Number of Auxiliary Contacts NC | 1 |
| Number of Poles | 3P |
| Rated Operational Voltage | Main Circuit 1000 V |
| Rated Frequency (f) | Main Circuit 50 / 60 Hz |
| Conventional Free-air Thermal Current (Ith) | acc. to IEC 60947-4-1, Open Contactors Θ = 40 °C 600 A |
| Rated Operational Current AC-1 (Ie) | (1000 V) 40 °C 600 A |
| (1000 V) 55 °C 500 A | |
| (1000 V) 70 °C 400 A | |
| (690 V) 40 °C 600 A | |
| (690 V) 55 °C 500 A | |
| (690 V) 70 °C 400 A | |
| Rated Operational Current AC-3 (Ie) | (415 V) 55 °C 400 A |
| (440 V) 55 °C 400 A | |
| (500 V) 55 °C 400 A | |
| (690 V) 55 °C 350 A | |
| (1000 V) 55 °C 155 A | |
| (380 / 400 V) 55 °C 400 A | |
| (220 / 230 / 240 V) 55 °C 400 A | |
| Rated Operational Current DC-1 (Ie) | (110 V) 1-Pole, 40 °C 600 A |
| (110 V) 2 Poles in Series, 40 °C 600 A | |
| (220 V) 3 Poles in Series, 40 °C 600 A | |
| (600 V) 3 Poles in Series, 40 °C 600 A | |
| Rated Operational Current DC-3 (Ie) | (110 V) 1-Pole, 40 °C 600 A |
| (110 V) 2 Poles in Series, 40 °C 600 A | |
| (220 V) 3 Poles in Series, 40 °C 600 A | |
| (600 V) 3 Poles in Series, 40 °C 600 A | |
| Rated Operational Current DC-5 (Ie) | (110 V) 1-Pole, 40 °C 600 A |
| (110 V) 2 Poles in Series, 40 °C 600 A | |
| (220 V) 3 Poles in Series, 40 °C 600 A | |
| (600 V) 3 Poles in Series, 40 °C 600 A | |
| Rated Operational Power AC-3 (Pe) | (415 V) 220 kW |
| (440 V) 220 kW | |
| (500 V) 250 kW | |
| (690 V) 315 kW | |
| (1000 V) 220 kW | |
| (380 / 400 V) 200 kW | |
| (220 / 230 / 240 V) 110 kW | |
| Rated Breaking Capacity AC-3 | 8 x Ie AC-3 |
| Rated Making Capacity AC-3 | 10 x Ie AC-3 |
| Short-Circuit Protective Devices | gG Type Fuses 630 A |
| Rated Short-time Withstand Current Low Voltage (Icw) | at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 840 A |
| at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 3100 A | |
| at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 4600 A | |
| at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 4400 A | |
| at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 2500 A | |
| Maximum Breaking Capacity | cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 4000 A |
| cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 3500 A | |
| Rated Insulation Voltage (Ui) | acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 1000 V |
| acc. to IEC 60947-5-1 and VDE 0110 (Gr. C) 1000 V | |
| acc. to UL/CSA 600 V | |
| Rated Impulse Withstand Voltage (Uimp) | Main Circuit 8 kV |
| Maximum Electrical Switching Frequency | (AC-1) 300 cycles per hour |
| (AC-2 / AC-4) 60 cycles per hour | |
| (AC-3) 300 cycles per hour | |
| Mechanical Durability | 3 million |
| Maximum Mechanical Switching Frequency | 300 cycles per hour |
| Coil Operating Limits | (acc. to IEC 60947-4-1) 0.85 x Uc Min. ... 1.1 x Uc Max. (at θ ≤ 70 °C) |
| Rated Control Circuit Voltage (Uc) | 50 Hz 250 ... 500 V |
| 60 Hz 250 ... 500 V | |
| DC Operation 250 ... 500 V | |
| Coil Consumption | Holding at Max. Rated Control Circuit Voltage 50 Hz 16.4 V·A |
| Holding at Max. Rated Control Circuit Voltage 60 Hz 16.4 V·A | |
| Holding at Max. Rated Control Circuit Voltage DC 4.9 V·A | |
| Holding at Max. Rated Control Circuit Voltage DC 4.9 W | |
| Pull-in at Max. Rated Control Circuit Voltage 50 Hz 1185 V·A | |
| Pull-in at Max. Rated Control Circuit Voltage 60 Hz 1185 V·A | |
| Pull-in at Max. Rated Control Circuit Voltage DC 1320 V·A | |
| Pull-in at Max. Rated Control Circuit Voltage DC 1320 W | |
| Power Loss | at Rated Operating Conditions per Pole 16 W |
| Operate Time | Between Coil De-energization and NC Contact Closing 45 ... 55 ms |
| Between Coil De-energization and NO Contact Opening 48 ... 58 ms | |
| Between Coil Energization and NC Contact Opening 45 ... 115 ms | |
| Between Coil Energization and NO Contact Closing 50 ... 120 ms | |
| Connecting Capacity Main Circuit | Bar 47 mm² |
| Rigid Al-Cable 240 mm² | |
| Rigid Al-Cable 2x240 mm² | |
| Rigid Cu-Cable 240 mm² | |
| Rigid Cu-Cable 2x240 mm² | |
| Connecting Capacity Auxiliary Circuit | Flexible with Ferrule 1x 0.75 ... 2.5 mm² |
| Flexible with Ferrule 2x 0.75 ... 2.5 mm² | |
| Flexible with Insulated Ferrule 2x 0.75 ... 2.5 mm² | |
| Flexible 1x0.75 ... 2.5 mm² | |
| Flexible 2x0.75 ... 2.5 mm² | |
| Solid 2 x 1 ... 4 mm² | |
| Stranded 2 x 1 .... 4 mm² | |
| Connecting Capacity | Bar 47 mm² |
| Rigid Al-Cable 2x240 mm² | |
| Rigid Cu-Cable 2x240 mm² | |
| Degree of Protection | acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20 |
| acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP00 | |
| Connecting Terminals (delivered in open position) Main Poles | M 3.5 (+,-) pozidriv 2 screw with cable clamp |
| Recommended Screw Driver | Main Circuit M10 |
| Control Circuit Pozidriv 2 | |
| Control Circuit M3.5 | |
| Tightening Torque | Cable Lug 35 N·m |
| Main Circuit 35 N·m | |
| Terminal Type | Main Circuit: Bars |
| Suitable for Product Class | Block ContactorsBlock Contactors |
| Product Name | Block Contactor |
| Technical UL/CSA | |
| Maximum Operating Voltage UL/CSA | Main Circuit 1000 V |
| General Use Rating UL/CSA | (1000 V AC) 550 A |
| (600 V AC) 550 A | |
| Horsepower Rating UL/CSA | (200 ... 208 V AC) Three Phase 125 Hp |
| (200 ... 208 V AC) Three Phase 125 hp | |
| (200 V AC) Three Phase 125 hp | |
| (208 V AC) Three Phase 125 hp | |
| (220 ... 240 V AC) Three Phase 150 Hp | |
| (220 ... 240 V AC) Three Phase 150 hp | |
| (440 ... 480 V AC) Three Phase 350 Hp | |
| (440 ... 480 V AC) Three Phase 350 hp | |
| (550 ... 600 V AC) Three Phase 400 Hp | |
| (550 ... 600 V AC) Three Phase 400 hp | |
| Full Load Amps Motor Use | (200 ... 208 V AC) Three Phase 358.8 A |
| (220 ... 240 V AC) Three Phase 360 A | |
| (440 ... 480 V AC) Three Phase 414 A | |
| (550 ... 600 V AC) Three Phase 382 A | |
| Environmental | |
| Ambient Air Temperature | Close to Contactor Fitted with Thermal O/L Relay (0.85 ... 1.1 Uc) -25 ... 50 °C |
| Close to Contactor without Thermal O/L Relay (0.85 ... 1.1 Uc) -40 ... 70 °C | |
| Close to Contactor for Storage -40 ... 70 °C | |
| Operation -40 ... 70 °C | |
| Storage -40 ... +70 °C | |
| Maximum Operating Altitude Permissible | Without Derating 3000 m |
| Resistance to Shock acc. to IEC 60068-2-27 | Shock Direction: A 5 g |
| Shock Direction: B1 5 g | |
| Shock Direction: B2 5 g | |
| Shock Direction: C1 5 g | |
| Shock Direction: C2 5 g | |
| Material Compliance | |
| Conflict Minerals Reporting Template (CMRT) | 9AKK108467A5658 |
| REACH Declaration | 2CMT2021-006202 |
| RoHS Declaration | 2CMT2021-006277 |
| RoHS Information | Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019 |
| Toxic Substances Control Act - TSCA | 2CMT2023-006525 |
| WEEE B2C / B2B | Business To Business |
| WEEE Category | 5. Small Equipment (No External Dimension More Than 50 cm) |
| ABB EcoSolutions | |
| ABB EcoSolutions | Yes |
| ABB Site Meeting Group Waste To Landfill Target | Non-hazardous waste is sent to a landfill, where there is no alternative option available within 100km of a facility |
| End Of Life Disassembling Instructions | 1SFC100112M0003 |
| Environmental Product Declaration - EPD | 1SFC100105D0201 |
| Improved Energy Efficiency for Customers | Product Efficiency - Product considered more energy-efficient compared to similar product on market or older products from the same line |
| Recyclability Rate of the Product acc. to EN45555 | Design for Closing Resource Loops - Standard EN45555 - 63.1 % |
| Sustainable Material Content in Product (wt. %) | Recycled Metal - 37 % |
| Certificates and Declarations | |
| ABS Certificate | 15-LD1408622-PDA |
| BV Certificate | BV_13409-C0BV |
| CB Certificate | SE-82316 |
| CCS Certificate | GB14T00030 |
| CQC Certificate | CQC2007010304256683 |
| CQC2011010304514755 | |
| Declaration of Conformity - CCC | 2020980304001300 |
| 2020980304001081 | |
| Declaration of Conformity - CE | 2CMT2019-005796 |
| Declaration of Conformity - UKCA | 2CMT2020-006118 |
| DNV Certificate | DNV_E-10966 |
| DNV GL Certificate | TAE00001W1 |
| EAC Certificate | 9AKK107046A8618 |
| GL Certificate | GL_42988-02HH |
| LOVAG Certificate | SE-0146190 |
| LR Certificate | 16-20064 |
| PRS Certificate | TE_2092_880423_16 |
| RINA Certificate | ELE060313XG_002 |
| RMRS Certificate | 9AKK107045A6978 |
| UL Certificate | 20121207-E36588 |
| UL Listing Card | UL_E36588 |
| Container Information | |
| Package Level 1 Units | box 1 piece |
| Package Level 1 Width | 280 mm |
| Package Level 1 Depth / Length | 375 mm |
| Package Level 1 Height | 310 mm |
| Package Level 1 Gross Weight | 12 kg |
| Package Level 1 EAN | 7320500250006 |
| External Classifications and Standards | |
| Object Classification Code | Q |
| ETIM 7 | EC000066 - Power contactor, AC switching |
| ETIM 8 | EC000066 - Power contactor, AC switching |
| ETIM 9 | EC000066 - Power contactor, AC switching |
| eClass | V11.0 : 27371003 |
| UNSPSC | 39121529 |
| IDEA Granular Category Code (IGCC) | 4758 >> Iec Contactors |
| E-Number (Finland) | 3709250 |
| E-Number (Norway) | 4115289 |
| E-Number (Sweden) | 3228335 |