View larger
AF30-30-11-41 1SBL277001R4111 ABB AF30-30-11-41 24-60V50/60HZ Contactor
AF30-30-11-41
1SBL277001R4111
ABB
1 Pcs.
Automation > Power contactor, AC switching
AF contactors to 38 A
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
Operating as a contactor, this ABB AF30-30-11-41 unit is engineered for frequent switching of electric motors and heavy power loads in industrial installations. Contactors act as electrically controlled heavy-duty switches that safely manage high currents within automated manufacturing and power distribution networks.
Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Number of Main Contacts NO: 3
- Number of Main Contacts NC: 0
- Number of Auxiliary Contacts NO: 1
- Number of Auxiliary Contacts NC: 1
- Standards: IEC 60947-1 / 60947-4-1 and EN 60947-1 / 60947-4-1, UL 508, CSA C22.2 N°14
- Rated Operational Voltage: Auxiliary Circuit 690 V Main Circuit 690 V
- Rated Frequency (f): Auxiliary Circuit 50 / 60 Hz Main Circuit 50 / 60 Hz
- Rated Operational Current AC-1 (I e ): (690 V) 40 °C 50 A (690 V) 60 °C 42 A (690 V) 70 °C 37 A
- Rated Operational Current AC-15 (I e ): (220 / 240 V) 4 A (24 / 127 V) 6 A (400 / 440 V) 3 A (500 V) 2 A (690 V) 2 A
- Rated Insulation Voltage (U i ): acc. to UL/CSA 600 V acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 690 V
- Rated Impulse Withstand Voltage (U imp ): 6 kV
- Maximum Mechanical Switching Frequency: 3600 cycles per hour
- Rated Control Circuit Voltage (U c ): 50 Hz 24 ... 60 V 60 Hz 24 ... 60 V
- Wire Stripping Length: Auxiliary Circuit 10 mm Control Circuit 10 mm Main Circuit 14 mm
- Terminal Type: Screw Terminals
- Maximum Operating Altitude Permissible: 3000 m
More info
▲AF30 contactors are used for controlling power circuits up to 690 V AC and 220 V DC. They are mainly used for controlling 3-phase motors, non-inductive or slightly inductive loads. AF... contactors include an electronic coil interface accepting a wide control voltage Uc min. ... Uc max. Only four coils cover control voltages between 24...500 V 50/60 Hz. AF contactors can manage large control voltage variations. One coil can be used for different control voltages used worldwide without any coil change. AF contactors have built-in surge protection and do not require additional surge suppressors. The AF... series 2-stack 3-pole contactors are of the block type design. - Main poles and auxiliary contact blocks: 3 main poles with a non-removable front-mounted 1 N.O. + 1 N.C. auxiliary contact block, side-mounted add-on auxiliary contact blocks (mechanically-linked auxiliary contacts compliant with Annex L of IEC 60947-5-1 including the "Mechanically Linked" symbol on the contactor side. N.C. mirror contacts compliant with Annex F of IEC 60947-4-1) - Control circuit: AC operated - Accessories: a wide range of accessories is available. Note: 2-stack contactors available in some countries: please consult your ABB representative.
Ordering
- EAN:
- 3471523111301
- Minimum Order Quantity:
- 1 piece
- Customs Tariff Number:
- 85369085
Dimensions
- Product Net Width:
- 45mm
- Product Net Depth:
- 111.5mm
- Product Net Height:
- 86mm
- Product Net Weight:
- 0.350kg
Container Information
- Package Level 1 Units:
- 1 piece
- Package Level 1 Width:
- 87 mm
- Package Level 1 Length:
- 121 mm
- Package Level 1 Height:
- 47 mm
- Package Level 1 Gross Weight:
- 0.35 kg
- Package Level 1 EAN:
- 3471523111301
- Package Level 2 Units:
- 36 piece
- Package Level 2 Width:
- 250 mm
- Package Level 2 Length:
- 300 mm
- Package Level 2 Height:
- 315 mm
- Package Level 3 Units:
- 864 piece
Technical
- Number of Main Contacts NO:
- 3
- Number of Main Contacts NC:
- 0
- Number of Auxiliary Contacts NO:
- 1
- Number of Auxiliary Contacts NC:
- 1
- Standards:
- IEC 60947-1 / 60947-4-1 and EN 60947-1 / 60947-4-1, UL 508, CSA C22.2 N°14
- Rated Operational Voltage:
- Auxiliary Circuit 690 V
Main Circuit 690 V
- Rated Frequency (f):
- Auxiliary Circuit 50 / 60 Hz
Main Circuit 50 / 60 Hz
- Conventional Free-air Thermal Current (Ith):
- acc. to IEC 60947-4-1, Open Contactors q = 40 °C 50 A
acc. to IEC 60947-5-1, q = 40 °C 16 A
- Rated Operational Current AC-1 (Ie):
- (690 V) 40 °C 50 A
(690 V) 60 °C 42 A
(690 V) 70 °C 37 A
- Rated Operational Current AC-3 (Ie):
- (220 / 230 / 240 V) 60 °C 33 A
(380 / 400 V) 60 °C 32 A
(415 V) 60 °C 32 A
(440 V) 60 °C 32 A
(500 V) 60 °C 28 A
(690 V) 60 °C 21 A
- Rated Operational Power AC-3 (Pe):
- (220 / 230 / 240 V) 9 kW
(380 / 400 V) 15 kW
(415 V) 15 kW
(440 V) 18.5 kW
(500 V) 18.5 kW
(690 V) 18.5 kW
- Rated Operational Current AC-15 (Ie):
- (220 / 240 V) 4 A
(24 / 127 V) 6 A
(400 / 440 V) 3 A
(500 V) 2 A
(690 V) 2 A
- Rated Short-time Withstand Current (Icw):
- at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 350 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 50 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 150 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 700 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 225 A
for 0.1 s 140 A
for 1 s 100 A
- Maximum Breaking Capacity:
- cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 500 A
cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 200 A
- Maximum Electrical Switching Frequency:
- AC-1 600 cycles per hour
AC-15 1200 cycles per hour
AC-2 / AC-4 150 cycles per hour
AC-3 1200 cycles per hour
DC-13 900 cycles per hour
- Rated Operational Current DC-13 (Ie):
- (110 V) 0.55 A / 60 W
(125 V) 0.55 A / 69 W
(220 V) 0.27 A / 60 W
(24 V) 6 A / 144 W
(250 V) 0.27 A / 68 W
(400 V) 0.15 A / 60 W
(48 V) 2.8 A / 134 W
(500 V) 0.13 A / 65 W
(600 V) 0.1 A / 60 W
(72 V) 1 A / 72 W
- Rated Insulation Voltage (Ui):
- acc. to UL/CSA 600 V
acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 690 V
- Rated Impulse Withstand Voltage (Uimp):
- 6 kV
- Maximum Mechanical Switching Frequency:
- 3600 cycles per hour
- Rated Control Circuit Voltage (Uc):
- 50 Hz 24 ... 60 V
60 Hz 24 ... 60 V
- Operate Time:
- Between Coil De-energization and NC Contact Closing 13...98 ms
Between Coil De-energization and NO Contact Opening 11...95 ms
Between Coil Energization and NC Contact Opening 38...90 ms
Between Coil Energization and NO Contact Closing 40...95 ms
- Connecting Capacity-Main Circuit:
- Flexible with Insulated Ferrule 1x 1.5...10 mm²
Flexible with Insulated Ferrule 2x 1.5...4 mm²
Flexible with Ferrule 1/2x 1.5...10 mm²
Rigid 1/2x 2.5...10 mm²
- Connecting Capacity-Auxiliary Circuit:
- Flexible with Ferrule 1/2x 0.75 ... 2.5 mm²
Flexible with Insulated Ferrule 1x 0.75 ... 2.5 mm²
Flexible with Insulated Ferrule 2x 0.75 ... 1.5 mm²
Rigid 1/2x 1...2.5 mm²
- Connecting Capacity-Control Circuit:
- Flexible with Ferrule 1/2x 0.75 ... 2.5 mm²
Flexible with Insulated Ferrule 1x 0.75...2.5 mm²
Flexible with Insulated Ferrule 2x 0.75...1.5 mm²
Rigid 1/2x 1...2.5 mm²
- Wire Stripping Length:
- Auxiliary Circuit 10 mm
Control Circuit 10 mm
Main Circuit 14 mm
- Degree of Protection:
- acc. to IEC 60529, IEC 60947-1, EN 60529 Auxiliary Terminals IP20
acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20
acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP20
- Terminal Type:
- Screw Terminals
Environmental
- Ambient Air Temperature:
- Close to Contactor for Storage -60...+80 °C
Close to Contactor Fitted with Thermal O/L Relay -25 ... +60 °C
Close to Contactor without Thermal O/L Relay -40 ... +70 °C
- Maximum Operating Altitude Permissible:
- 3000 m
- Resistance to Shock acc. to IEC 60068-2-27:
- Closed, Shock Direction: B1 25 g
Open, Shock Direction: B1 5 g
Shock Direction: A 30 g
Shock Direction: B2 15 g
Shock Direction: C1 25 g
Shock Direction: C2 25 g
- Resistance to Vibrations acc. to IEC 60068-2-6:
- 5...300 Hz 4 g closed position / 2 g open position
- RoHS Status:
- Planned to follow EU Directive 2002/95/EC August 18, 2005 and amendment after 2008 Q1
Technical UL/CSA
- General Use Rating UL/CSA:
- (600 V AC) 50 A
- Horsepower Rating UL/CSA:
- (120 V AC) Single Phase 2 Hp
(240 V AC) Single Phase 5 Hp
(200 ... 208 V AC) Three Phase 10 Hp
(220 ... 240 V AC) Three Phase 10 Hp
(440 ... 480 V AC) Three Phase 20 Hp
(550 ... 600 V AC) Three Phase 25 Hp
- Tightening Torque UL/CSA:
- Auxiliary Circuit 11 in·lb
Control Circuit 11 in·lb
Main Circuit 22 in·lb
Certificates and Declarations (Document Number)
- ABS Certificate:
- ABS_15-GE1349500-PDA_90682247
- CB Certificate:
- CB_SE_70856M1
- cUL Certificate:
- UL_20091124-E312527-7-1
- Declaration of Conformity - CE:
- 1SBD250165C1000
- DNV Certificate:
- DNV-GL_E13871
- EAC Certificate:
- EAC_RU C-FR ME77 B01010
- GL Certificate:
- DNV-GL_E13871
- GOST Certificate:
- GOST_POCCFR.ME77.B07175.pdf
- LR Certificate:
- LRS_1300087E1
- RINA Certificate:
- RINA_ELE084013XG
- RMRS Certificate:
- RMRS_1400682124
- RoHS Information:
- 1SBD251012E1000
Classifications
- ETIM 5:
- EC000066 - Magnet contactor, AC-switching
- UNSPSC:
- 39121529