View larger
AF26-22-00-41 1SBL237501R4100 ABB AF26-22-00-41 24-60V50/60HZ Contactor
AF26-22-00-41
1SBL237501R4100
ABB
1 Pcs.
Automation > Power contactor, AC switching
AF contactors to 38 A
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
Serving as a robust contactor, the ABB AF26-22-00-41 unit provides dependable switching performance for electrical power distribution and industrial machinery. These electromagnetic switching devices allow control systems to safely regulate high-power circuits through low-voltage control signals.
Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Number of Main Contacts NO: 2
- Number of Main Contacts NC: 2
- Number of Auxiliary Contacts NO: 0
- Number of Auxiliary Contacts NC: 0
- Standards: IEC 60947-1 / 60947-4-1 and EN 60947-1 / 60947-4-1, UL 508, CSA C22.2 N°14
- Rated Operational Voltage: Main Circuit 690 V
- Rated Frequency (f): Main Circuit 50 / 60 Hz
- Conventional Free-air Thermal Current (I th ): acc. to IEC 60947-4-1, Open Contactors q = 40 °C 55 A
- Rated Operational Current AC-1 (I e ): (690 V) 40 °C 45 A (690 V) 60 °C 40 A (690 V) 70 °C 32 A
- Maximum Electrical Switching Frequency: AC-1 600 cycles per hour
- Rated Insulation Voltage (U i ): acc. to UL/CSA 600 V acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 690 V
- Rated Impulse Withstand Voltage (U imp ): 6 kV
- Maximum Mechanical Switching Frequency: 3600 cycles per hour
- Rated Control Circuit Voltage (U c ): 50 Hz 24 ... 60 V 60 Hz 24 ... 60 V
- Wire Stripping Length: Control Circuit 10 mm Main Circuit 12 mm
- Terminal Type: Screw Terminals
More info
▲AF26 4-pole contactors are used for controlling power circuits up to 690 V AC and 440 V DC. They are mainly used for controlling non-inductive or slightly inductive loads (i.e. resistance furnaces...). AF... contactors include an electronic coil interface accepting a wide control voltage Uc min. ... Uc max. Only four coils cover control voltages between 24...500 V 50/60 Hz. AF contactors can manage large control voltage variations. One coil can be used for different control voltages used worldwide without any coil change. AF contactors have built-in surge protection and do not require additional surge suppressors. The AF... series 4-pole contactors are of the block type design. - Main poles and auxiliary contact blocks: 2 N.O. + 2 N.C. main poles, front and side-mounted add-on auxiliary contact blocks (mechanically-linked auxiliary contacts compliant with Annex L of IEC 60947-5-1. N.C. mirror contacts compliant with Annex F of IEC 60947-4-1) - Control circuit: AC operated - Accessories: a wide range of accessories is available.
Ordering
- EAN:
- 3471523116405
- Minimum Order Quantity:
- 1 piece
- Customs Tariff Number:
- 85369085
Dimensions
- Product Net Width:
- 45mm
- Product Net Depth:
- 101mm
- Product Net Height:
- 86mm
- Product Net Weight:
- 0.360kg
Container Information
- Package Level 1 Units:
- 1 piece
- Package Level 1 Width:
- 87 mm
- Package Level 1 Length:
- 103 mm
- Package Level 1 Height:
- 47 mm
- Package Level 1 Gross Weight:
- 0.36 kg
- Package Level 1 EAN:
- 3471523116405
- Package Level 2 Units:
- 45 piece
- Package Level 2 Width:
- 250 mm
- Package Level 2 Length:
- 300 mm
- Package Level 2 Height:
- 315 mm
- Package Level 3 Units:
- 1080 piece
Technical
- Number of Main Contacts NO:
- 2
- Number of Main Contacts NC:
- 2
- Number of Auxiliary Contacts NO:
- 0
- Number of Auxiliary Contacts NC:
- 0
- Standards:
- IEC 60947-1 / 60947-4-1 and EN 60947-1 / 60947-4-1, UL 508, CSA C22.2 N°14
- Rated Operational Voltage:
- Main Circuit 690 V
- Rated Frequency (f):
- Main Circuit 50 / 60 Hz
- Conventional Free-air Thermal Current (Ith):
- acc. to IEC 60947-4-1, Open Contactors q = 40 °C 55 A
- Rated Operational Current AC-1 (Ie):
- (690 V) 40 °C 45 A
(690 V) 60 °C 40 A
(690 V) 70 °C 32 A
- Rated Operational Current AC-3 (Ie):
- (220 / 230 / 240 V) 60 °C 23.2 A
(380 / 400 V) 60 °C 22 A
(415 V) 60 °C 21.2 A
(440 V) 60 °C 20 A
(500 V) 60 °C 17.6 A
(690 V) 60 °C 10.5 A
- Rated Operational Power AC-3 (Pe):
- (220 / 230 / 240 V) 5.5 kW
(400 V) 11 kW
(415 V) 11 kW
(440 V) 11 kW
(500 V) 11 kW
(690 V) 9 kW
- Rated Short-time Withstand Current (Icw):
- at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 300 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 55 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 150 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 450 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 225 A
- Maximum Electrical Switching Frequency:
- AC-1 600 cycles per hour
- Rated Insulation Voltage (Ui):
- acc. to UL/CSA 600 V
acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 690 V
- Rated Impulse Withstand Voltage (Uimp):
- 6 kV
- Maximum Mechanical Switching Frequency:
- 3600 cycles per hour
- Rated Control Circuit Voltage (Uc):
- 50 Hz 24 ... 60 V
60 Hz 24 ... 60 V
- Operate Time:
- Between Coil De-energization and NC Contact Closing 13...98 ms
Between Coil De-energization and NO Contact Opening 11...95 ms
Between Coil Energization and NC Contact Opening 38...90 ms
Between Coil Energization and NO Contact Closing 40...95 ms
- Connecting Capacity-Main Circuit:
- Flexible with Insulated Ferrule 1x 1.5...16 mm²
Flexible with Insulated Ferrule 2x 1.5...16 mm²
Flexible with Ferrule 1/2x 1.5...16 mm²
Rigid 1/2x 1.5...16 mm²
- Connecting Capacity-Control Circuit:
- Flexible with Ferrule 1/2x 0.75 ... 2.5 mm²
Flexible with Insulated Ferrule 1x 0.75...2.5 mm²
Flexible with Insulated Ferrule 2x 0.75...1.5 mm²
Rigid 1/2x 1...2.5 mm²
- Wire Stripping Length:
- Control Circuit 10 mm
Main Circuit 12 mm
- Degree of Protection:
- acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20
acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP20
- Terminal Type:
- Screw Terminals
Environmental
- Ambient Air Temperature:
- Close to Contactor for Storage -60...+80 °C
Near Contactor for Operation in Free Air -40 ... +70 °C
- Maximum Operating Altitude Permissible:
- 3000 m
- Resistance to Shock acc. to IEC 60068-2-27:
- Closed, Shock Direction: A 30 g
Closed, Shock Direction: B1 25 g
Closed, Shock Direction: B2 15 g
Closed, Shock Direction: C1 25 g
Closed, Shock Direction: C2 25 g
Open, Shock Direction: A 25 g
Open, Shock Direction: B1 5 g
Open, Shock Direction: B2 10 g
Open, Shock Direction: C1 20 g
Open, Shock Direction: C2 20 g
- Resistance to Vibrations acc. to IEC 60068-2-6:
- 5...300 Hz 4 g closed position / 2 g open position
- RoHS Status:
- Following EU Directive 2011/65/EC
Technical UL/CSA
- General Use Rating UL/CSA:
- (600 V AC) 45 A
- Tightening Torque UL/CSA:
- Control Circuit 11 in·lb
Main Circuit 22 in·lb
Certificates and Declarations (Document Number)
- ABS Certificate:
- ABS_15-GE1349500-PDA_90682247
- CB Certificate:
- CB_SE_70858M1
- cUL Certificate:
- UL_20100802-E319322-3-1
- Declaration of Conformity - CE:
- 1SBD250169C1000
- DNV Certificate:
- DNV-GL_E13871
- EAC Certificate:
- EAC_RU C-FR ME77 B01010
- GL Certificate:
- DNV-GL_E13871
- GOST Certificate:
- GOST_POCCFR.ME77.B07175.pdf
- LR Certificate:
- LRS_1300087E1
- RINA Certificate:
- RINA_ELE084013XG
- RMRS Certificate:
- RMRS_1400682124
- RoHS Information:
- 1SBD251015E1001
Classifications
- ETIM 5:
- EC000066 - Magnet contactor, AC-switching
- UNSPSC:
- 39121529