ABB 1SFL707001R7022 1SFL707001R7022 ABB AF2050-30-22 100-250V 50/60Hz / 100-250 DC Contactor View larger
Images are for illustrative purposes only. Please refer to data sheet for details

1SFL707001R7022 ABB AF2050-30-22 100-250V 50/60Hz / 100-250 DC Contactor

1SFL707001R7022

707001

ABB

1 Pcs.

AF2050-30-22 100-250V 50/60Hz / 100-250 DC Contactor CONTACTOR#AF2050-30-22#100-250V A.C./D.C

Automation > Power contactor, AC switching
"A" SECRLP

Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.

Request a Quote

Pricing and availability are confirmed for each enquiry. Add your required quantity to begin.

No account, online checkout or payment is required.

More info

Ordering
Minimum Order Quantity1 piece
Customs Tariff Number85364900
Popular Downloads
EPLAN Data9AAC133509_EPLAN
Data Sheet, Technical Information1SBC100214C0202
Data Sheet, Technical Information (Part 2)1SAC200017M0002
Instructions and Manuals1SFC101002M5501
CAD Dimensional Drawing2CDC001079B0201
Dimensions
Product Net Width438 mm
Product Net Depth / Length244 mm
Product Net Height392 mm
Product Net Weight33 kg
Dimension Diagram53540930-7
Technical
Number of Main Contacts NO3
Number of Main Contacts NC0
Number of Auxiliary Contacts NO2
Number of Auxiliary Contacts NC2
Number of Poles3P
Rated Operational VoltageMain Circuit 1000 V
Rated Frequency (f)Main Circuit 50 / 60 Hz
Conventional Free-air Thermal Current (Ith)acc. to IEC 60947-4-1, Open Contactors Θ = 40 °C 2050 A
Rated Operational Current AC-1 (Ie)(1000 V) 40 °C 2050 A
(1000 V) 55 °C 1750 A
(1000 V) 70 °C 1500 A
(690 V) 40 °C 2050 A
(690 V) 55 °C 1750 A
(690 V) 70 °C 1500 A
Rated Operational Current AC-3 (Ie)(415 V) 55 °C 1060 A
(440 V) 55 °C 1060 A
(500 V) 55 °C 970 A
(690 V) 55 °C 970 A
(1000 V) 55 °C 425 A
(220 / 230 / 240 V) 55 °C 1060 A
Rated Operational Current DC-1 (Ie)(220 V) 3 Poles in Series, 40 °C 2050 A
(600 V) 3 Poles in Series, 40 °C 2050 A
(850 V) 3 Poles in Series, 40 °C 2050 A
Rated Operational Power AC-3 (Pe)(415 V) 630 kW
(440 V) 710 kW
(690 V) 1000 kW
(1000 V) 630 kW
Rated Breaking Capacity AC-38 x Ie AC-3
Rated Making Capacity AC-310 x Ie AC-3
Rated Short-time Withstand Current Low Voltage (Icw)at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 2200 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 7500 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 12000 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 10000 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 5500 A
Maximum Breaking Capacitycos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 12000 A
Rated Insulation Voltage (Ui)acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 1000 V
acc. to UL/CSA 1000 V
Rated Impulse Withstand Voltage (Uimp)Main Circuit 8 kV
Maximum Electrical Switching Frequency(AC-1) 60 cycles per hour
Mechanical Durability0.5 million
Maximum Mechanical Switching Frequency300 cycles per hour
Coil Operating Limits(acc. to IEC 60947-4-1) 0.85 x Uc Min. ... 1.1 x Uc Max. (at θ ≤ 70 °C)
Rated Control Circuit Voltage (Uc)50 Hz 100 ... 250 V
50 Hz / 60 Hz 100 ... 250 V
60 Hz 100 ... 250 V
DC Operation 100 ... 250 V
Coil ConsumptionHolding at Max. Rated Control Circuit Voltage 50 Hz 48 V·A
Holding at Max. Rated Control Circuit Voltage 60 Hz 48 V·A
Holding at Max. Rated Control Circuit Voltage DC 20.5 V·A
Pull-in at Max. Rated Control Circuit Voltage 50 Hz 2450 V·A
Pull-in at Max. Rated Control Circuit Voltage 60 Hz 2450 V·A
Pull-in at Max. Rated Control Circuit Voltage DC 2290 V·A
Power Lossat Rated Operating Conditions per Pole 125 W
Operate TimeBetween Coil De-energization and NC Contact Closing 35 ... 55 ms
Between Coil De-energization and NO Contact Opening 35 ... 55 ms
Between Coil Energization and NC Contact Opening 50 ... 80 ms
Between Coil Energization and NO Contact Closing 50 ... 80 ms
Connecting Capacity Main CircuitBar 100 mm²
Connecting Capacity Auxiliary CircuitFlexible with Ferrule 2x 0.75 ... 2.5 mm²
Flexible with Insulated Ferrule 1x 0.75 ... 2.5 mm²
Flexible with Insulated Ferrule 2x 0.75 ... 2.5 mm²
Flexible 1x0.75 ... 2.5 mm²
Flexible 2x0.75 ... 2.5 mm²
Solid 2 x 1 ... 4 mm²
Stranded 2 x 1 .... 4 mm²
Connecting CapacityBar 100 mm²
Degree of Protectionacc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20
acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP00
Connecting Terminals (delivered in open position) Main PolesM 3.5 (+,-) pozidriv 2 screw with cable clamp
Recommended Screw DriverMain Circuit M12
Control Circuit Pozidriv 2
Control Circuit M3.5
Tightening TorqueCable Lug 45 N·m
Main Circuit 45 N·m
Terminal TypeMain Circuit: Bars
Suitable for Product ClassBlock ContactorsBlock Contactors
Product NameBlock Contactor
Technical UL/CSA
Maximum Operating Voltage UL/CSAMain Circuit 1000 V
General Use Rating UL/CSA(1000 V AC) 2100 A
(600 V AC) 2100 A
Environmental
Ambient Air TemperatureClose to Contactor Fitted with Thermal O/L Relay (0.85 ... 1.1 Uc) -25 ... 50 °C
Close to Contactor without Thermal O/L Relay (0.85 ... 1.1 Uc) -40 ... 70 °C
Close to Contactor for Storage -40 ... 70 °C
Operation -40 ... 70 °C
Storage -40 ... +70 °C
Maximum Operating Altitude PermissibleWithout Derating 3000 m
Material Compliance
Conflict Minerals Reporting Template (CMRT)9AKK108467A5658
REACH Declaration2CMT2021-006202
RoHS Declaration2CMT2021-006277
RoHS InformationFollowing EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Toxic Substances Control Act - TSCA2CMT2023-006525
WEEE B2C / B2BBusiness To Business
WEEE Category5. Small Equipment (No External Dimension More Than 50 cm)
ABB EcoSolutions
End Of Life Disassembling Instructions1SFC100112M0005
Environmental Product Declaration - EPD1SFC100110D0201
2TFP200026A1001
Certificates and Declarations
ABS Certificate15-LD1408622-PDA
BV CertificateBV_13409-C0BV
CB CertificateSEMKO_SE-74013
CCS CertificateGB14T00030
CQC CertificateCQC2003010304101933
CQC2015010304752548
Declaration of Conformity - CCC2020980304001303
2020980304001043
Declaration of Conformity - CE2CMT2019-005796
Declaration of Conformity - UKCA2CMT2020-006118
EAC Certificate9AKK107046A8618
LR Certificate16-20064
RINA CertificateELE060313XG_002
RMRS Certificate9AKK107045A6978
UL CertificateUL_20130904-E73397
UL Listing CardUL_E73397
Container Information
Package Level 1 Unitsbox 1 piece
Package Level 1 Width555 mm
Package Level 1 Depth / Length365 mm
Package Level 1 Height500 mm
Package Level 1 Gross Weight35 kg
Package Level 1 EAN7320500359105
External Classifications and Standards
Object Classification CodeQ
ETIM 7EC000066 - Power contactor, AC switching
ETIM 8EC000066 - Power contactor, AC switching
ETIM 9EC000066 - Power contactor, AC switching
eClassV11.0 : 27371003
UNSPSC39121529
IDEA Granular Category Code (IGCC)4758 >> Iec Contactors
E-Number (Finland)3709260

ETIM for 1SFL707001R7022 Low-voltage industrial controls and switchgear (EC000066)
Feature Name Feature Value
Rated control supply voltage AC 50 Hz (EF003978) 100 V
Rated control supply voltage AC 60 Hz (EF003979) 100 V
Rated control supply voltage DC (EF003980) 100 V
Voltage type for actuating (EF008242) AC/DC
Rated operation current Ie at AC-1, 400 V (EF001393) 2050 A
Modular version (EF001126) No
Number of auxiliary contacts as normally open contact (EF001376) 2
Number of auxiliary contacts as normally closed contact (EF001377) 2
Type of electrical connection of main circuit (EF006819) Screw connection
Number of normally closed contacts as main contact (EF001375) 0
Number of normally open contacts as main contact (EF001374) 3

Product Datasheet

Electrica Online Product Datasheet Prepared from the current product description, catalog data and structured technical attributes.