View larger
1SFL527002R1400 ABB AF205-30-00-14 Contactor
1SFL527002R1400
527002
ABB
1 Pcs.
Automation > Power contactor, AC switching
AF contactors 100A to 370A
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
Abb 1SFL527002R1400 ABB AF205-30-00-14 Contactor is an extremely robust electromechanical switching device engineered for heavy industrial power distribution and high-current motor control. Heavy manufacturing plants and energy systems rely on such high-capacity contactors to safely manage immense electrical loads under rigorous operating schedules. Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Number of Main Contacts NO: 3
- Number of Main Contacts NC: 0
- Number of Auxiliary Contacts NO: 0
- Number of Auxiliary Contacts NC: 0
- Rated Operational Voltage: Main Circuit 1000 V
- Rated Frequency (f): Main Circuit 50/60 Hz
- Conventional Free-air Thermal Current (I th ): acc. to IEC 60947-4-1, Open Contactors q = 40 °C 350 A
- Rated Breaking Capacity AC-3 acc. to IEC 60947-4-1: 8 x Ie AC-3
- Rated Making Capacity AC-3 acc. to IEC 60947-4-1: 10 x Ie AC-3
- Short-Circuit Protective Devices: gG Type Fuses 400 A
- Maximum Electrical Switching Frequency: AC-3 300 cycles per hour AC-1 300 cycles per hour AC-2 / AC-4 150 cycles per hour
- Rated Operational Current DC-1 (I e ): (110 V) 2 Poles in Series, 40 °C 275 A (220 V) 3 Poles in Series, 40 °C 275 A
- Rated Operational Current DC-3 (I e ): (110 V) 2 Poles in Series, 40 °C 275 A (220 V) 3 Poles in Series, 40 °C 275 A
- Rated Operational Current DC-5 (I e ): (110 V) 2 Poles in Series, 40 °C 275 A (220 V) 3 Poles in Series, 40 °C 275 A
- Rated Insulation Voltage (U i ): acc. to UL/CSA 600 V acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 1000 V
- Rated Impulse Withstand Voltage (U imp ): Main Circuit 8 kV
More info
▲A 3-phase Contactor suitable for various applications such as Motor starting, Isolation, By-pass and Distribution application up to max 1000 V. Operated with wide control voltage range 250-500 V, 50/60 Hz and DC
Ordering
- EAN:
- 7320500480533
- Minimum Order Quantity:
- 1 piece
- Customs Tariff Number:
- 85364900
Dimensions
- Product Net Width:
- 105.0mm
- Product Net Depth:
- 152.0mm
- Product Net Height:
- 196.0mm
- Product Net Weight:
- 2.740kg
Container Information
- Package Level 1 Units:
- 1 piece
- Package Level 1 Width:
- 200 mm
- Package Level 1 Length:
- 220 mm
- Package Level 1 Height:
- 280 mm
- Package Level 1 Gross Weight:
- 3.19 kg
- Package Level 1 EAN:
- 7320500480533
Technical
- Number of Main Contacts NO:
- 3
- Number of Main Contacts NC:
- 0
- Number of Auxiliary Contacts NO:
- 0
- Number of Auxiliary Contacts NC:
- 0
- Rated Operational Voltage:
- Main Circuit 1000 V
- Rated Frequency (f):
- Main Circuit 50/60 Hz
- Conventional Free-air Thermal Current (Ith):
- acc. to IEC 60947-4-1, Open Contactors q = 40 °C 350 A
- Rated Operational Current AC-1 (Ie):
- (690 V) 55 °C 300 A
(690 V) 40 °C 350 A
(1000 V) 40 °C 275 A
(1000 V) 55 °C 250 A
(690 V) 70 °C 240 A
(1000 V) 70 °C 200 A
- Rated Operational Current AC-3 (Ie):
- (1000 V) 55 °C 100 A
(690 V) 55 °C 165 A
(220 / 230 / 240 V) 55 °C 205 A
(415 V) 55 °C 205 A
(440 V) 55 °C 205 A
(380 / 400 V) 55 °C 205 A
(500 V) 55 °C 165 A
- Rated Operational Power AC-3 (Pe):
- (500 V) 110 kW
(1000 V) 132 kW
(690 V) 160 kW
(220 / 230 / 240 V) 55 kW
(380 / 400 V) 110 kW
(440 V) 132 kW
(415 V) 110 kW
- Rated Breaking Capacity AC-3 acc. to IEC 60947-4-1:
- 8 x Ie AC-3
- Rated Making Capacity AC-3 acc. to IEC 60947-4-1:
- 10 x Ie AC-3
- Short-Circuit Protective Devices:
- gG Type Fuses 400 A
- Rated Short-time Withstand Current (Icw):
- at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 1640 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 947 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 350 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 2050 A
at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 670 A
- Maximum Breaking Capacity:
- cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 3500 A
cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 2500 A
- Maximum Electrical Switching Frequency:
- AC-3 300 cycles per hour
AC-1 300 cycles per hour
AC-2 / AC-4 150 cycles per hour
- Rated Operational Current DC-1 (Ie):
- (110 V) 2 Poles in Series, 40 °C 275 A
(220 V) 3 Poles in Series, 40 °C 275 A
- Rated Operational Current DC-3 (Ie):
- (110 V) 2 Poles in Series, 40 °C 275 A
(220 V) 3 Poles in Series, 40 °C 275 A
- Rated Operational Current DC-5 (Ie):
- (110 V) 2 Poles in Series, 40 °C 275 A
(220 V) 3 Poles in Series, 40 °C 275 A
- Rated Insulation Voltage (Ui):
- acc. to UL/CSA 600 V
acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 1000 V
- Rated Impulse Withstand Voltage (Uimp):
- Main Circuit 8 kV
- Mechanical Durability:
- 5 million
- Maximum Mechanical Switching Frequency:
- 300 cycles per hour
- Coil Operating Limits:
- (acc. to IEC 60947-4-1)0.85 x Uc Min. ... 1.1 x Uc Max. (at θ ≤ 70 °C) °C
- Rated Control Circuit Voltage (Uc):
- 60 Hz 250…500 V
50 Hz 250…500 V
DC Operation 250…500 V
- Coil Consumption:
- Pull-in at Max. Rated Control Circuit Voltage 60 Hz 185 V·A
Holding at Max. Rated Control Circuit Voltage DC 3.9 W
Holding at Max. Rated Control Circuit Voltage 50 Hz 16.1 V·A
Pull-in at Max. Rated Control Circuit Voltage DC 188 W
Pull-in at Max. Rated Control Circuit Voltage 50 Hz 185 V·A
Holding at Max. Rated Control Circuit Voltage 60 Hz 16.1 V·A
- Operate Time:
- Between Coil Energization and NO Contact Closing 25…55 ms
Between Coil De-energization and NO Contact Opening 37…47 ms
- Connecting Capacity-Main Circuit:
- Rigid Al-Cable 1x95…185 mm²
Rigid Cu-Cable 2x50…120 mm²
Flexible 1x6…120 mm²
- Connecting Capacity-Auxiliary Circuit:
- Solid 1x1…4 mm²
Flexible with Insulated Ferrule 1x0.75…2.5 mm²
Stranded 2x1…4 mm²
Flexible 2x0.75…2.5 mm²
Flexible with Ferrule 1x0.75…2.5 mm²
- Degree of Protection:
- acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20
acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP00
- Terminal Type:
- Main Circuit: Bars
Environmental
- Ambient Air Temperature:
- Close to Contactor Fitted with Thermal O/L Relay (0.85 ... 1.1 Uc) -25…+50 °C
Close to Contactor without Thermal O/L Relay (0.85 ... 1.1 Uc) -40…+70 °C
Close to Contactor for Storage -40…+70 °C
- Maximum Operating Altitude Permissible:
- 3000 m
- RoHS Status:
- Following EU Directive 2002/95/EC August 18, 2005 and amendment
Technical UL/CSA
- Maximum Operating Voltage UL/CSA:
- Main Circuit 600 V
- General Use Rating UL/CSA:
- (600 V AC) 300 A
- Horsepower Rating UL/CSA:
- (208 V AC) Three Phase 60 Hp
(440 ... 480 V AC) Three Phase 150 Hp
(550 ... 600 V AC) Three Phase 200 Hp
(220 ... 240 V AC) Three Phase 75 Hp
(200 V AC) Three Phase 60 Hp
Certificates and Declarations (Document Number)
- CB Certificate:
- SE-71798
- Declaration of Conformity - CE:
- 2CMT004613
- RINA Certificate:
- ELE060313XG/002
- RoHS Information:
- 1SFC101055D0202
Classifications
- E-nummer:
- 3210139
- ETIM 5:
- EC000066 - Magnet contactor, AC-switching
- UNSPSC:
- 39121529