View larger
1SFL647001R6911 ABB AF1250-30-11 48-130V 50/60Hz / 48-130V DC Contactor
1SFL647001R6911
647001
ABB
1 Pcs.
Automation > Power contactor, AC switching
"A" SECRLP
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
An ABB contactor is a high-capacity switching device deployed in heavy industrial plants to regulate immense electrical loads, large motor drives, and primary power distribution systems. Its rugged construction guarantees reliable operation in extreme environments. Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Minimum Order Quantity: 1 piece
- Customs Tariff Number: 85364900
- EPLAN Data: 9AAC129651_EPLAN
- Data Sheet, Technical Information: 1SBC100214C0202
- Data Sheet, Technical Information (Part 2): 1SAC200017M0002
- Instructions and Manuals: 1SFC380023-en
- CAD Dimensional Drawing: 2CDC001079B0201
- Product Net Width: 210 mm
- Product Net Depth / Length: 242 mm
- Product Net Height: 344 mm
- Product Net Weight: 14.6 kg
- Number of Main Contacts NO: 3
- Number of Main Contacts NC: 0
- Number of Auxiliary Contacts NO: 1
- Number of Auxiliary Contacts NC: 1
- Number of Poles: 3P
More info
▲| Ordering | |
|---|---|
| Minimum Order Quantity | 1 piece |
| Customs Tariff Number | 85364900 |
| Popular Downloads | |
| EPLAN Data | 9AAC129651_EPLAN |
| Data Sheet, Technical Information | 1SBC100214C0202 |
| Data Sheet, Technical Information (Part 2) | 1SAC200017M0002 |
| Instructions and Manuals | 1SFC380023-en |
| CAD Dimensional Drawing | 2CDC001079B0201 |
| Dimensions | |
| Product Net Width | 210 mm |
| Product Net Depth / Length | 242 mm |
| Product Net Height | 344 mm |
| Product Net Weight | 14.6 kg |
| Technical | |
| Number of Main Contacts NO | 3 |
| Number of Main Contacts NC | 0 |
| Number of Auxiliary Contacts NO | 1 |
| Number of Auxiliary Contacts NC | 1 |
| Number of Poles | 3P |
| Rated Operational Voltage | Main Circuit 1000 V |
| Rated Frequency (f) | Main Circuit 50 / 60 Hz |
| Conventional Free-air Thermal Current (Ith) | acc. to IEC 60947-4-1, Open Contactors Θ = 40 °C 1050 A |
| Rated Operational Current AC-1 (Ie) | (1000 V) 40 °C 1260 A |
| (1000 V) 55 °C 1040 A | |
| (1000 V) 70 °C 875 A | |
| (690 V) 40 °C 1260 A | |
| (690 V) 55 °C 1040 A | |
| (690 V) 70 °C 875 A | |
| Rated Operational Current DC-1 (Ie) | (220 V) 3 Poles in Series, 40 °C 1250 A |
| (600 V) 3 Poles in Series, 40 °C 1250 A | |
| (850 V) 3 Poles in Series, 40 °C 1250 A | |
| Rated Operational Current DC-3 (Ie) | (220 V) 3 Poles in Series, 40 °C 1250 A |
| (600 V) 3 Poles in Series, 40 °C 1250 A | |
| (850 V) 3 Poles in Series, 40 °C 1250 A | |
| Rated Operational Current DC-5 (Ie) | (220 V) 3 Poles in Series, 40 °C 1250 A |
| (600 V) 3 Poles in Series, 40 °C 1250 A | |
| (850 V) 3 Poles in Series, 40 °C 1250 A | |
| Rated Breaking Capacity AC-3 | 8 x Ie AC-3 |
| Rated Making Capacity AC-3 | 10 x Ie AC-3 |
| Rated Short-time Withstand Current Low Voltage (Icw) | at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 1500 A |
| at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 5200 A | |
| at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 8000 A | |
| at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 7200 A | |
| at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 4000 A | |
| Maximum Breaking Capacity | cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 7500 A |
| cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 7000 A | |
| Rated Insulation Voltage (Ui) | acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 1000 V |
| acc. to IEC 60947-5-1 and VDE 0110 (Gr. C) 1000 V | |
| acc. to UL/CSA 600 V | |
| Rated Impulse Withstand Voltage (Uimp) | Main Circuit 8 kV |
| Maximum Electrical Switching Frequency | (AC-1) 300 cycles per hour |
| Mechanical Durability | 0.5 million |
| Maximum Mechanical Switching Frequency | 300 cycles per hour |
| Coil Operating Limits | (acc. to IEC 60947-4-1) 0.85 x Uc Min. ... 1.1 x Uc Max. (at θ ≤ 70 °C) |
| Rated Control Circuit Voltage (Uc) | 50 Hz 48 ... 130 V |
| 60 Hz 48 ... 130 V | |
| DC Operation 48 ... 130 V | |
| Coil Consumption | Holding at Max. Rated Control Circuit Voltage 50 Hz 12 V·A |
| Holding at Max. Rated Control Circuit Voltage 60 Hz 12 V·A | |
| Holding at Max. Rated Control Circuit Voltage DC 5 V·A | |
| Pull-in at Max. Rated Control Circuit Voltage 50 Hz 1100 V·A | |
| Pull-in at Max. Rated Control Circuit Voltage 60 Hz 1100 V·A | |
| Pull-in at Max. Rated Control Circuit Voltage DC 1020 V·A | |
| Power Loss | at Rated Operating Conditions per Pole 80 W |
| Operate Time | Between Coil De-energization and NC Contact Closing 50 ... 70 ms |
| Between Coil De-energization and NO Contact Opening 53 ... 73 ms | |
| Between Coil Energization and NC Contact Opening 45 ... 115 ms | |
| Between Coil Energization and NO Contact Closing 50 ... 120 ms | |
| Connecting Capacity Main Circuit | Bar 50 mm² |
| Connecting Capacity Auxiliary Circuit | Flexible with Ferrule 2x 0.75 ... 2.5 mm² |
| Flexible with Insulated Ferrule 2x 0.75 ... 2.5 mm² | |
| Flexible 2x0.75 ... 2.5 mm² | |
| Solid 2 x 1 ... 4 mm² | |
| Stranded 1 x 1 .... 4 mm² | |
| Stranded 2 x 1 .... 4 mm² | |
| Connecting Capacity | Bar 50 mm² |
| Degree of Protection | acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20 |
| acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP00 | |
| Connecting Terminals (delivered in open position) Main Poles | M 3.5 (+,-) pozidriv 2 screw with cable clamp |
| Recommended Screw Driver | Main Circuit M12 |
| Control Circuit Pozidriv 2 | |
| Control Circuit M3.5 | |
| Tightening Torque | Cable Lug 45 N·m |
| Main Circuit 45 N·m | |
| Terminal Type | Main Circuit: Bars |
| Suitable for Product Class | Block ContactorsBlock Contactors |
| Product Name | Block Contactor |
| Technical UL/CSA | |
| Horsepower Rating NEMA | (230 V AC) Three Phase 300 Hp |
| (460 V AC) Three Phase 600 Hp | |
| (575 V AC) Three Phase 600 Hp | |
| Maximum Operating Voltage UL/CSA | Main Circuit 1000 V |
| General Use Rating UL/CSA | (1000 V AC) 1210 A |
| Environmental | |
| Ambient Air Temperature | Close to Contactor Fitted with Thermal O/L Relay (0.85 ... 1.1 Uc) -25 ... 50 °C |
| Close to Contactor without Thermal O/L Relay (0.85 ... 1.1 Uc) -40 ... 70 °C | |
| Close to Contactor for Storage -40 ... 70 °C | |
| Operation -40 ... 70 °C | |
| Storage -40 ... +70 °C | |
| Maximum Operating Altitude Permissible | Without Derating 3000 m |
| Resistance to Shock acc. to IEC 60068-2-27 | Shock Direction: A 5 g |
| Shock Direction: B1 5 g | |
| Shock Direction: B2 5 g | |
| Shock Direction: C1 5 g | |
| Shock Direction: C2 5 g | |
| Material Compliance | |
| Conflict Minerals Reporting Template (CMRT) | 9AKK108467A5658 |
| REACH Declaration | 2CMT2021-006202 |
| RoHS Declaration | 2CMT2021-006277 |
| RoHS Information | Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019 |
| Toxic Substances Control Act - TSCA | 2CMT2023-006525 |
| WEEE B2C / B2B | Business To Business |
| WEEE Category | 5. Small Equipment (No External Dimension More Than 50 cm) |
| ABB EcoSolutions | |
| End Of Life Disassembling Instructions | 1SFC100112M0004 |
| Environmental Product Declaration - EPD | 1SFC100109D0201 |
| Certificates and Declarations | |
| ABS Certificate | 15-LD1408622-PDA |
| BV Certificate | BV_13409-C0BV |
| CB Certificate | SE-82863 |
| CCS Certificate | GB14T00030 |
| CQC Certificate | CQC2006010304213519 |
| CQC2012010304540079 | |
| Declaration of Conformity - CCC | 2020980304001302 |
| 2020980304001044 | |
| Declaration of Conformity - CE | 2CMT2019-005796 |
| Declaration of Conformity - UKCA | 2CMT2020-006118 |
| DNV GL Certificate | TAE00001W1 |
| EAC Certificate | 9AKK107046A8618 |
| LR Certificate | 16-20064 |
| PRS Certificate | TE_2092_880423_16 |
| RINA Certificate | ELE060313XG_002 |
| RMRS Certificate | 9AKK107045A6978 |
| UL Certificate | UL_20130930-E73397 |
| UL Listing Card | UL_E73397 |
| Container Information | |
| Package Level 1 Units | box 1 piece |
| Package Level 1 Width | 280 mm |
| Package Level 1 Depth / Length | 375 mm |
| Package Level 1 Height | 310 mm |
| Package Level 1 Gross Weight | 16 kg |
| Package Level 1 EAN | 7320500355077 |
| External Classifications and Standards | |
| Object Classification Code | Q |
| ETIM 7 | EC000066 - Power contactor, AC switching |
| ETIM 8 | EC000066 - Power contactor, AC switching |
| ETIM 9 | EC000066 - Power contactor, AC switching |
| eClass | V11.0 : 27371003 |
| UNSPSC | 39121529 |
| IDEA Granular Category Code (IGCC) | 4758 >> Iec Contactors |
| E-Number (Norway) | 4115381 |
| E-Number (Sweden) | 4115381 |