View larger
1SBL137201R1100
137201
ABB
1 Pcs.
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
| Ordering | |
|---|---|
| Minimum Order Quantity | 1 piece |
| Customs Tariff Number | 85364900 |
| Popular Downloads | |
| EPLAN Data | 9AAC159656_EPLAN |
| Data Sheet, Technical Information | 1SBC100214C0202 |
| Instructions and Manuals | 1SBC101027M6801 |
| Instructions and Manuals (Part 2) | 1SAC200017M0002 |
| CAD Dimensional Drawing | 2CDC001079B0201 |
| Dimensions | |
| Product Net Width | 45 mm |
| Product Net Depth / Length | 77 mm |
| Product Net Height | 86 mm |
| Product Net Weight | 0.27 kg |
| Technical | |
| Number of Main Contacts NO | 4 |
| Number of Main Contacts NC | 0 |
| Number of Auxiliary Contacts NO | 0 |
| Number of Auxiliary Contacts NC | 0 |
| Number of Poles | 4P |
| Standards | IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60335-2-40 LZGH2 A2L, UL 60947-1, UL 60947-4-1, CSA C22.2 No. 60335-2-40 LZGH2 A2L, CAN/CSA C22.2 No.60947-1, CAN/CSA C22.2 No.60947-4-1 |
| Rated Operational Voltage | Main Circuit 690 V |
| Rated Frequency (f) | Control Circuit 50 / 60 Hz |
| Main Circuit 50 / 60 Hz | |
| Conventional Free-air Thermal Current (Ith) | acc. to IEC 60947-4-1, Open Contactors Θ = 40 °C 35 A |
| Rated Operational Current AC-1 (Ie) | (690 V) 40 °C 25 A |
| (690 V) 60 °C 25 A | |
| (690 V) 70 °C 22 A | |
| Rated Operational Current AC-3 (Ie) | (415 V) 60 °C 9 A |
| (440 V) 60 °C 9 A | |
| (500 V) 60 °C 9.5 A | |
| (690 V) 60 °C 7 A | |
| (380 / 400 V) 60 °C 9 A | |
| (220 / 230 / 240 V) 60 °C 9 A | |
| Rated Operational Current DC-1 (Ie) | (110 V) 1-Pole, 40 °C 10 A |
| (110 V) 1-Pole, 60 °C 10 A | |
| (110 V) 1-Pole, 70 °C 10 A | |
| (110 V) 2 Poles in Series, 40 °C 25 A | |
| (110 V) 2 Poles in Series, 60 °C 25 A | |
| (110 V) 2 Poles in Series, 70 °C 22 A | |
| (110 V) 3 Poles in Series, 40 °C 25 A | |
| (110 V) 3 Poles in Series, 60 °C 25 A | |
| (110 V) 3 Poles in Series, 70 °C 22 A | |
| (110 V) 4 Poles in Series, 40 °C 25 A | |
| (110 V) 4 Poles in Series, 60 °C 25 A | |
| (110 V) 4 Poles in Series, 70 °C 22 A | |
| (220 V) 2 Poles in Series, 40 °C 10 A | |
| (220 V) 2 Poles in Series, 60 °C 10 A | |
| (220 V) 2 Poles in Series, 70 °C 10 A | |
| (220 V) 3 Poles in Series, 40 °C 25 A | |
| (220 V) 3 Poles in Series, 60 °C 25 A | |
| (220 V) 3 Poles in Series, 70 °C 22 A | |
| (220 V) 4 Poles in Series, 40 °C 25 A | |
| (220 V) 4 Poles in Series, 60 °C 25 A | |
| (220 V) 4 Poles in Series, 70 °C 22 A | |
| (440 V) 4 Poles in Series, 40 °C 10 A | |
| (440 V) 4 Poles in Series, 60 °C 10 A | |
| (440 V) 4 Poles in Series, 70 °C 10 A | |
| (72 V) 1-Pole, 40 °C 25 A | |
| (72 V) 1-Pole, 60 °C 25 A | |
| (72 V) 1-Pole, 70 °C 22 A | |
| (72 V) 2 Poles in Series, 40 °C 25 A | |
| (72 V) 2 Poles in Series, 60 °C 25 A | |
| (72 V) 2 Poles in Series, 70 °C 22 A | |
| (72 V) 3 Poles in Series, 40 °C 25 A | |
| (72 V) 3 Poles in Series, 60 °C 25 A | |
| (72 V) 3 Poles in Series, 70 °C 22 A | |
| (72 V) 4 Poles in Series, 40 °C 25 A | |
| (72 V) 4 Poles in Series, 60 °C 25 A | |
| (72 V) 4 Poles in Series, 70 °C 22 A | |
| Rated Operational Current DC-3 (Ie) | (110 V) 1-Pole, 40 °C 6 A |
| (110 V) 1-Pole, 60 °C 6 A | |
| (110 V) 1-Pole, 70 °C 6 A | |
| (110 V) 2 Poles in Series, 40 °C 25 A | |
| (110 V) 2 Poles in Series, 60 °C 25 A | |
| (110 V) 2 Poles in Series, 70 °C 22 A | |
| (110 V) 3 Poles in Series, 40 °C 25 A | |
| (110 V) 3 Poles in Series, 60 °C 25 A | |
| (110 V) 3 Poles in Series, 70 °C 22 A | |
| (110 V) 4 Poles in Series, 40 °C 25 A | |
| (110 V) 4 Poles in Series, 60 °C 25 A | |
| (110 V) 4 Poles in Series, 70 °C 22 A | |
| (220 V) 2 Poles in Series, 40 °C 6 A | |
| (220 V) 2 Poles in Series, 60 °C 6 A | |
| (220 V) 2 Poles in Series, 70 °C 6 A | |
| (220 V) 3 Poles in Series, 40 °C 25 A | |
| (220 V) 3 Poles in Series, 60 °C 25 A | |
| (220 V) 3 Poles in Series, 70 °C 22 A | |
| (220 V) 4 Poles in Series, 40 °C 25 A | |
| (220 V) 4 Poles in Series, 60 °C 25 A | |
| (220 V) 4 Poles in Series, 70 °C 22 A | |
| (440 V) 4 Poles in Series, 40 °C 6 A | |
| (440 V) 4 Poles in Series, 60 °C 6 A | |
| (440 V) 4 Poles in Series, 70 °C 6 A | |
| (72 V) 1-Pole, 40 °C 25 A | |
| (72 V) 1-Pole, 60 °C 25 A | |
| (72 V) 1-Pole, 70 °C 22 A | |
| (72 V) 2 Poles in Series, 40 °C 25 A | |
| (72 V) 2 Poles in Series, 60 °C 25 A | |
| (72 V) 2 Poles in Series, 70 °C 22 A | |
| (72 V) 3 Poles in Series, 40 °C 25 A | |
| (72 V) 3 Poles in Series, 60 °C 25 A | |
| (72 V) 3 Poles in Series, 70 °C 22 A | |
| (72 V) 4 Poles in Series, 40 °C 25 A | |
| (72 V) 4 Poles in Series, 60 °C 25 A | |
| (72 V) 4 Poles in Series, 70 °C 22 A | |
| Rated Operational Current DC-5 (Ie) | (110 V) 1-Pole, 40 °C 4 A |
| (110 V) 1-Pole, 60 °C 4 A | |
| (110 V) 1-Pole, 70 °C 4 A | |
| (110 V) 2 Poles in Series, 40 °C 10 A | |
| (110 V) 2 Poles in Series, 60 °C 10 A | |
| (110 V) 2 Poles in Series, 70 °C 10 A | |
| (110 V) 3 Poles in Series, 40 °C 25 A | |
| (110 V) 3 Poles in Series, 60 °C 25 A | |
| (110 V) 3 Poles in Series, 70 °C 22 A | |
| (110 V) 4 Poles in Series, 40 °C 25 A | |
| (110 V) 4 Poles in Series, 60 °C 25 A | |
| (110 V) 4 Poles in Series, 70 °C 22 A | |
| (220 V) 2 Poles in Series, 40 °C 4 A | |
| (220 V) 2 Poles in Series, 60 °C 4 A | |
| (220 V) 2 Poles in Series, 70 °C 4 A | |
| (220 V) 3 Poles in Series, 40 °C 9 A | |
| (220 V) 3 Poles in Series, 60 °C 9 A | |
| (220 V) 3 Poles in Series, 70 °C 9 A | |
| (220 V) 4 Poles in Series, 40 °C 10 A | |
| (220 V) 4 Poles in Series, 60 °C 10 A | |
| (220 V) 4 Poles in Series, 70 °C 10 A | |
| (440 V) 4 Poles in Series, 40 °C 4 A | |
| (440 V) 4 Poles in Series, 60 °C 4 A | |
| (440 V) 4 Poles in Series, 70 °C 4 A | |
| (72 V) 1-Pole, 40 °C 9 A | |
| (72 V) 1-Pole, 60 °C 9 A | |
| (72 V) 1-Pole, 70 °C 9 A | |
| (72 V) 2 Poles in Series, 40 °C 25 A | |
| (72 V) 2 Poles in Series, 60 °C 25 A | |
| (72 V) 2 Poles in Series, 70 °C 22 A | |
| (72 V) 3 Poles in Series, 40 °C 25 A | |
| (72 V) 3 Poles in Series, 60 °C 25 A | |
| (72 V) 3 Poles in Series, 70 °C 22 A | |
| (72 V) 4 Poles in Series, 40 °C 25 A | |
| (72 V) 4 Poles in Series, 60 °C 25 A | |
| (72 V) 4 Poles in Series, 70 °C 22 A | |
| Rated Operational Power AC-3 (Pe) | (400 V) 4 kW |
| (415 V) 4 kW | |
| (440 V) 4 kW | |
| (500 V) 5.5 kW | |
| (690 V) 5.5 kW | |
| (380 / 400 V) 4 kW | |
| (220 / 230 / 240 V) 2.2 kW | |
| Rated Short-time Withstand Current Low Voltage (Icw) | at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 150 A |
| at 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 35 A | |
| at 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 60 A | |
| at 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 300 A | |
| at 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 80 A | |
| Maximum Breaking Capacity | cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 250 A |
| cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 106 A | |
| Rated Insulation Voltage (Ui) | acc. to IEC 60947-4-1 690 V |
| acc. to UL/CSA 600 V | |
| Rated Impulse Withstand Voltage (Uimp) | 6 kV |
| Maximum Electrical Switching Frequency | (AC-1) 600 cycles per hour |
| Maximum Mechanical Switching Frequency | 3600 cycles per hour |
| Rated Control Circuit Voltage (Uc) | 50 Hz 24 ... 60 V |
| 60 Hz 24 ... 60 V | |
| DC Operation 20 ... 60 V | |
| Power Loss | at Rated Operating Conditions AC-1 per Pole 0.8 W |
| at Rated Operating Conditions AC-3 per Pole 0.1 W | |
| Operate Time | Between Coil De-energization and NC Contact Closing 13 ... 98 ms |
| Between Coil De-energization and NO Contact Opening 11 ... 95 ms | |
| Between Coil Energization and NC Contact Opening 38 ... 90 ms | |
| Between Coil Energization and NO Contact Closing 40 ... 95 ms | |
| Mounting on DIN Rail | TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715 |
| TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715 | |
| Mounting by Screws (not supplied) | 2 x M4 Screws Placed Diagonally |
| Connecting Capacity Main Circuit | Flexible with Ferrule 1/2x 0.75 ... 6 mm² |
| Flexible with Insulated Ferrule 1x 0.75 ... 4 mm² | |
| Flexible with Insulated Ferrule 2x 0.75 ... 2.5 mm² | |
| Rigid Solid 1/2x 1 ... 4 mm² | |
| Rigid Stranded 1/2x 1 ... 6 mm² | |
| Connecting Capacity Auxiliary Circuit | Rigid Solid 1/2x 1 ... 2.5 mm² |
| Rigid Stranded 1/2x 1 ... 2.5 mm² | |
| Connecting Capacity Control Circuit | Flexible with Ferrule 1/2x 0.75 ... 2.5 mm² |
| Flexible with Insulated Ferrule 1x 0.75 ... 2.5 mm² | |
| Flexible with Insulated Ferrule 2x 0.75 ... 1.5 mm² | |
| Rigid Solid 1/2x 1 ... 2.5 mm² | |
| Rigid Stranded 1/2x 1 ... 2.5 mm² | |
| Wire Stripping Length | Control Circuit 10 mm |
| Main Circuit 10 mm | |
| Degree of Protection | acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20 |
| acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP20 | |
| Tightening Torque | Control Circuit 1.2 N·m |
| Main Circuit 1.5 N·m | |
| Terminal Type | Screw Terminals |
| Product Name | Block Contactor |
| Technical UL/CSA | |
| Maximum Operating Voltage UL/CSA | Main Circuit 600 V |
| General Use Rating UL/CSA | (600 V AC) 25 A |
| Connecting Capacity Main Circuit UL/CSA | Rigid Solid 1/2x 16-10 AWG |
| Rigid Stranded 1/2x 16-10 AWG | |
| Connecting Capacity Auxiliary Circuit UL/CSA | Rigid Solid 1/2x 18-14 AWG |
| Rigid Stranded 1/2x 18-14 AWG | |
| Connecting Capacity Control Circuit UL/CSA | Rigid Solid 1/2x 18-14 AWG |
| Rigid Stranded 1/2x 18-14 AWG | |
| Tightening Torque UL/CSA | Control Circuit 11 in·lb |
| Main Circuit 13 in·lb | |
| Environmental | |
| Ambient Air Temperature | Close to Contactor for Storage -60 ... +80 °C |
| Near Contactor for Operation in Free Air -40 ... 70 °C | |
| Climatic Withstand | Category B according to IEC 60947-1 Annex Q |
| Maximum Operating Altitude Permissible | Without Derating 3000 m |
| Resistance to Shock acc. to IEC 60068-2-27 | Closed, Shock Direction: B1 25 g |
| Open, Shock Direction: B1 5 g | |
| Shock Direction: A 30 g | |
| Shock Direction: B2 15 g | |
| Shock Direction: C1 25 g | |
| Shock Direction: C2 25 g | |
| Resistance to Vibrations | 4g Closed Position & 2g Open position 5 ... 300 Hz |
| Pollution Degree | 3 |
| Material Compliance | |
| Conflict Minerals Reporting Template (CMRT) | 9AKK108467A5658 |
| REACH Declaration | 2CMT2021-006202 |
| RoHS Declaration | 2CMT2021-006277 |
| RoHS Information | Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019 |
| SCIP | 9a2024b2-7b20-48b2-a422-5e42fd29b832 China |
| Simplified SCIP | 9d7426f4-f1b0-4e9d-a261-f4fed9680884 Germany |
| 43c07225-bfbd-4df8-bba3-a9bb024209d4 Croatia | |
| 6986262f-e8c8-43db-9edb-a2da7eb59914 Czech Republic | |
| e452a4a5-da23-4452-af04-107a3cee877e Germany | |
| c75bae1b-a578-4d4b-adbd-5e960176d7f9 Poland | |
| f4be448f-0d61-4c66-b37d-1dfcc098f78b France | |
| 05ef92e8-06ef-4a24-b65d-a78b5f54782d France | |
| bc17b5a2-e9ef-4071-b1e5-21533cab9f09 Germany | |
| 76f3da67-1bfe-4688-94be-8c8d0c8af059 Sweden | |
| 513f019a-a544-406f-8af0-d911defb72fe Spain | |
| b67a602d-5a2d-4c1f-ab58-a13c607cb073 Bulgaria | |
| a8506c7d-948d-452c-bb48-df3ac5083bac Greece | |
| bef41b8d-26dd-4384-93ee-fd178e63536c Belgium | |
| 07e8204d-cef5-4d15-b686-fbe5ae79333d Portugal | |
| d95cdafb-eb92-4cf8-94de-6094c8fe58b9 Germany | |
| 4c988fae-3112-4aa4-9c34-02628b245ee2 Sweden | |
| 4bbc481a-8254-40e0-a82f-360dcb9a3302 Germany | |
| 72e31217-b174-422f-863f-6a05243e1680 Denmark | |
| d1ced2ca-8124-43f6-9b8d-e95306f80505 Norway | |
| 3f24a468-55e8-4d63-8d22-72bd18fa32d5 Hungary | |
| c4dd9633-49c8-4625-b2e7-f4447cc25582 Hungary | |
| 1733edec-f442-4e18-9960-d3d2bb5147a8 Estonia | |
| 2b88aee2-2573-467e-9e3a-ed8892050cfc Finland | |
| a8865e5c-d28e-43fd-9522-8a4483d62054 Poland | |
| 10312506-8861-44f5-8f52-801652dd0788 Netherlands | |
| 6bfd8f98-b8e8-4c52-9c5c-a7c60ec8a0ff Poland | |
| 5dfd636f-de77-4550-8d68-eb12f51c7c9f Belgium | |
| Toxic Substances Control Act - TSCA | 2CMT2023-006525 |
| WEEE B2C / B2B | Business To Business |
| WEEE Category | 5. Small Equipment (No External Dimension More Than 50 cm) |
| ABB EcoSolutions | |
| ABB EcoSolutions | Yes |
| ABB Site Meeting Group Waste To Landfill Target | No non-hazardous waste is sent to a landfill |
| End Of Life Disassembling Instructions | 1SBC101080M6801 |
| Environmental Product Declaration - EPD | 1SBD250584E3000 |
| Improved Energy Efficiency for Customers | Product Efficiency - Product considered more energy-efficient compared to similar product on market or older products from the same line |
| Recyclability Rate of the Product acc. to EN45555 | Design for Closing Resource Loops - Standard EN45555 - 92.7 % |
| Certificates and Declarations | |
| A2L Certificate – UL | 9AKK108469A4875 |
| 9AKK108469A4879 | |
| ABS Certificate | ABS_20-2060694-PDA |
| BV Certificate | BV_2634H24898C1 |
| CB Certificate | CB_SE-113345 |
| CCC Certificate | CCC_2024010304656669 |
| CQC Certificate | CQC2010010304445624 |
| CQC2020010304298240 | |
| Declaration of Conformity - CCC | 2020980304001253 |
| 2020980304001082 | |
| Declaration of Conformity - CE | 1SBD250001U1000 |
| Declaration of Conformity - UKCA | 1SBD250032U1000 |
| DNV Certificate | DNV_TAE00001AF-4 |
| GOST Certificate | GOST_POCCFR.ME77.B07175.pdf |
| KC Certificate | KC_HW02016-15007C |
| LR Certificate | LRS_LR23403517TA-02 |
| RINA Certificate | RINA_ELE142224XG |
| RMRS Certificate | RMRS_1802705280 |
| UL Certificate | UL-US-L319322-13-72119002-5 |
| UL-CA-L319322-43-72119002-6 | |
| UL Listing Card | UL_E319322 |
| Container Information | |
| Package Level 1 Units | box 1 piece |
| Package Level 1 Width | 87 mm |
| Package Level 1 Depth / Length | 79 mm |
| Package Level 1 Height | 47 mm |
| Package Level 1 Gross Weight | 0.27 kg |
| Package Level 1 EAN | 3471523115019 |
| Package Level 2 Units | box 27 piece |
| Package Level 2 Width | 250 mm |
| Package Level 2 Depth / Length | 300 mm |
| Package Level 2 Height | 315 mm |
| Package Level 2 Gross Weight | 14.58 kg |
| External Classifications and Standards | |
| Object Classification Code | Q |
| ETIM 7 | EC000066 - Power contactor, AC switching |
| ETIM 8 | EC000066 - Power contactor, AC switching |
| ETIM 9 | EC000066 - Power contactor, AC switching |
| eClass | V11.0 : 27371003 |
| UNSPSC | 39121529 |
| IDEA Granular Category Code (IGCC) | 4758 >> Iec Contactors |
| E-Number (Finland) | 3705809 |
| E-Number (Sweden) | 3211405 |
| Feature Name | Feature Value |
|---|---|
| Rated control supply voltage AC 50 Hz (EF003978) | 24 V |
| Rated control supply voltage AC 60 Hz (EF003979) | 24 V |
| Rated control supply voltage DC (EF003980) | 20 V |
| Voltage type for actuating (EF008242) | AC/DC |
| Rated operation current Ie at AC-1, 400 V (EF001393) | 25 A |
| Rated operation current Ie at AC-3, 400 V (EF001392) | 9 A |
| Rated operation power at AC-3, 400 V (EF001364) | 4 kW |
| Modular version (EF001126) | No |
| Number of auxiliary contacts as normally open contact (EF001376) | 0 |
| Number of auxiliary contacts as normally closed contact (EF001377) | 0 |
| Type of electrical connection of main circuit (EF006819) | Screw connection |
| Number of normally closed contacts as main contact (EF001375) | 0 |
| Number of normally open contacts as main contact (EF001374) | 4 |