ABB 2CSR772140R1164 2CSR772140R1164 ABB I.com.DS202CRM 2p C 16A 10kA 30mA View larger
Images are for illustrative purposes only. Please refer to data sheet for details

2CSR772140R1164 ABB I.com.DS202CRM 2p C 16A 10kA 30mA

2CSR772140R1164

772140

ABB

1 Pcs.

I.com.DS202CRM 2p C 16A 10kA 30mA DS202CR M C16 A30 Residual Current Circuit Breaker with Overcurrent Protection

Automation > Earth leakage circuit breaker
Tertiary / Industrial

Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.

Request a Quote

Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.

Request Quote

Product Overview

An ABB residual current circuit breaker with overcurrent protection component, part number 2CSR772140R1164, is built for heavy-duty electrical distribution protection. These modular units secure circuits from overloads, short circuits, and ground fault hazards.

Pricing, availability and lead time are confirmed per enquiry through an RFQ.

  • 2CDS200931R0001: G2C-H6-L+R Signal / Auxiliary contact
  • 2CDS200932R0001: G2C-S/H6-L+R Signal / Auxiliary contact
  • 2CDS200932R0011: G2C-S/H6-L+R-KL Signal / Auxiliary contact

More info

▲
  • Extended Product Type:
    DS202CR M C16 A30
  • Product ID:
    2CSR772140R1164
  • EAN:
    4022903034483
  • Catalog Description:
    DS202CR M C16 A30 Residual Current Circuit Breaker with Overcurrent Protection
  • Long Description:
    The DS202CR series RCBO is a 2P in two-modules device for the protection of end user single-phase circuits against overload and short-circuit currents. Protection against the effects of sinusoidal alternating and direct pulsating earth fault currents. Protection against indirect contacts and additional protection against direct contacts (with sensitivity = 30 mA).
+
–

Accessories

IdentifierDescriptionTypeQtyUnit Of Measure
2CDS200931R0001
G2C-H6-L+R Signal / Auxiliary contactG2C-H6-L+R1piece
2CDS200932R0001
G2C-S/H6-L+R Signal / Auxiliary contactG2C-S/H6-L+R1piece
2CDS200932R0011
G2C-S/H6-L+R-KL Signal / Auxiliary contactG2C-S/H6-L+R-KL1piece

Eco Transparency

Technical

  • Standards:
    IEC/EN 61009-1
    IEC/EN 61009-2-1
  • Tripping Characteristic:
    C
  • Type of Residual Current:
    A type
  • Rated Operational Voltage:
    acc. to IEC 60898-1 230 V
  • Rated Insulation Voltage (Ui):
    acc. to IEC/EN 60664-1 440 V
  • Rated Impulse Withstand Voltage (Uimp):
    4 kV
  • Input Voltage Type:
    AC
  • Rated Current (In):
    16 A
  • Rated Residual Current:
    30 mA
  • Rated Short-Circuit Capacity:
    10 kA
  • Rated Ultimate Short-Circuit Breaking Capacity (Icu):
    10 kA
  • Rated Service Short-Circuit Breaking Capacity (Ics):
    7.5 kA
  • Maximum Surge Current:
    0.25 kA
  • Leakage Current Type:
    A
  • Frequency (f):
    50 Hz
  • Rated Frequency (f):
    50 Hz
  • Power Loss:
    4.20 W
  • Power Supply Connection:
    Arbitrary
  • Energy Limiting Class:
    3
  • Electrical Endurance:
    10000 operations
  • Mechanical Endurance:
    20000 operations
  • Number of Poles:
    2
  • Number of Protected Poles:
    2
  • Fault Indication:
    Blue flag on window
  • Operating Characteristic:
    Instantaneous
  • Overvoltage Category:
    III
  • Position of Neutral Terminals:
    Right
    Left
  • Tightening Torque:
    4 N·m
  • Accessory Type:
    Auxiliary contact
    Signal contact / auxiliary contact
  • Earthing Switch Type:
    Undelayed
  • Mounting Type:
    DIN-Rail
  • Mounting Position:
    Any
  • Accessories Available:
    Yes
  • Number of Batteries:
    0
  • Cable Size:
    35 mm²
  • Connecting Capacity:
    Busbar 10…10 mm²
    Flexible 1...25 mm²
    Rigid Solid 1…35 mm²
  • Rated Cross-Section:
    1 - Solid-Core 1 … 35 mm²
    4 - Multi-Wired 1 … 25 mm²
  • Wire Stripping Length:
    11 mm

Environmental

  • Ambient Air Temperature:
    Operation -25 ... +55 °C
    Storage -40 ... +70 °C
  • Degree of Protection:
    IP20
  • Pollution Degree:
    3
  • Environmental Conditions:
    28 cycle
    with 55 °C / 90-96 %
    and 25 °C / 95-100 %
  • RoHS Status:
    Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
  • RoHS Information:
    9AKK108466A5162
  • REACH Declaration:
    9AKK108466A9708
  • Conflict Minerals Reporting Template (CMRT):
    9AKK108468A3363

Dimensions

  • Width in Number of Modular Spacings:
    2
  • Product Net Width:
    36mm
  • Product Net Height:
    86mm
  • Product Net Depth / Length:
    72mm
  • Product Net Weight:
    0.220kg
  • Built-In Depth (t2):
    72 mm

Ordering

  • Minimum Order Quantity:
    1 piece
  • Package Level 1 Units:
    box 1 piece
  • Package Level 1 Gross Weight:
    0.245 kg
  • Customs Tariff Number:
    85363010
  • Country of Origin:
    Poland (PL)

Certificates and Declarations

Popular Downloads

Classifications

  • ETIM 8:
    EC000905 - Earth leakage circuit breaker
  • ETIM 9:
    EC000905 - Earth leakage circuit breaker
  • WEEE Category:
    5. Small Equipment (No External Dimension More Than 50 cm)
  • WEEE B2C / B2B:
    Business To Consumer
  • CN8:
    85363010
  • eClass:
    V11.0 : 27142207
  • Object Classification Code:
    F

Product Datasheet

Electrica Online Product Datasheet Prepared from the current product description, catalog data and structured technical attributes.