View larger
2CSR255480R1164 ABB I.com.DS200 1p+N C 16A A APR 10kA 30mA
2CSR255480R1164
255480
ABB
1 Pcs.
Automation > Earth leakage circuit breaker
Tertiary / Industrial
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
A residual current circuit breaker with overcurrent protection safeguards electrical wiring from overloads while detecting dangerous earth leakage currents. ABB part number 2CSR255480R1164 provides dependable safety switching for building automation and industrial applications. Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- ABB EcoSolutions: Yes
- EcoSolutions Profile: 9AKK108470A2163
- Recyclability Rate of the Product acc. to EN45555: Design for Closing Resource Loops - Standard EN45555 - 75.20 %
- ABB Site Meeting Group Waste To Landfill Target: No non-hazardous waste is sent to a landfill
- Sustainable Material Content in Packaging (wt. %): Recycled Cardboard - 98 %
- Extended Product Lifetime: Product Durability
- End Of Life Disassembling Instructions: 9AKK108469A2268
- Environmental Product Declaration - EPD: 9AKK108468A5756
- Type of Residual Current: Type A APR
- Test Voltage (Ut): Minimum 170 V
- Dielectric Test Voltage: 2 kV
- Rated Ultimate Short-Circuit Breaking Capacity (I cu ): 10 kA
- Rated Residual Breaking Capacity (IΔm): EN 61009-1 6000 A
- Rated Service Short-Circuit Breaking Capacity (I cs ): 7.5 kA
- Maximum Surge Current: 3 kA
- Power Supply Connection: Arbitrary
More info
▲| ABB EcoSolutions | |
|---|---|
| ABB EcoSolutions | Yes |
| EcoSolutions Profile | 9AKK108470A2163 |
| Recyclability Rate of the Product acc. to EN45555 | Design for Closing Resource Loops - Standard EN45555 - 75.20 % |
| ABB Site Meeting Group Waste To Landfill Target | No non-hazardous waste is sent to a landfill |
| UL 2799 Zero Waste To Landfill Validation available | |
| Sustainable Material Content in Packaging (wt. %) | Recycled Cardboard - 98 % |
| Recycled Paper - 00 % | |
| Chemically Recycled Polymer - 00 % | |
| Extended Product Lifetime | Product Durability |
| End Of Life Disassembling Instructions | 9AKK108469A2268 |
| Environmental Product Declaration - EPD | 9AKK108468A5756 |
| Technical | |
| Type of Residual Current | Type A APR |
| Test Voltage (Ut) | Minimum 170 V |
| Maximum 264 V | |
| Dielectric Test Voltage | 2 kV |
| Rated Ultimate Short-Circuit Breaking Capacity (Icu) | 10 kA |
| Rated Residual Breaking Capacity (IΔm) | EN 61009-1 6000 A |
| IEC 61009-1 6000 A | |
| Rated Service Short-Circuit Breaking Capacity (Ics) | 7.5 kA |
| Maximum Surge Current | 3 kA |
| Power Supply Connection | Arbitrary |
| Contact Position Indication | Red ON / Green OFF |
| Energy Limiting Class | 3 |
| Electrical Endurance | 10000 cycle |
| Mechanical Endurance | 20000 cycle |
| Number of Protected Poles | 1 |
| Number of Poles | 1P+N |
| Number of Modular Spacings per DIN Rail | 2 |
| Fault Indication | Blue Flag on Toggle |
| Operating Characteristic | 10ms Delay (High Immunity) |
| Position of Neutral Terminals | Right |
| Tightening Torque | 2.8 N·m |
| Accessory Type | Auxiliary contact, Signal contact / auxiliary contact, Shunt trip, Auxiliary contact for bottom fitting, Overvoltage release, Motor operating device |
| Actuator Type | Toggle - Insulation group II, Black RAL 9005, sealable in ON-OFF positions |
| Housing Type | Insulation group I - II, RAL 7035 |
| Screw Terminal Type | Failsafe Bi-directional Cylinder-lift Terminal |
| Accessories Available | Yes |
| Surge Immunity acc. to IEC 61000-4-5 | 3000 A |
| Number of Batteries | 0 |
| Connecting Capacity | Busbar 10 ... 10 mm² |
| Stranded 0.75 ... 25 mm² | |
| Flexible with Ferrule 0.75 ... 16 mm² | |
| Flexible 0.75 ... 16 mm² | |
| Wire Stripping Length | 12 mm |
| Terminal Type | Screw Terminals |
| Electrical | |
| Tripping Characteristic | C |
| Rated Operational Voltage | acc. to IEC 60898-1 240 V |
| Rated Insulation Voltage (Ui) | acc. to IEC/EN 60664-1 500 V |
| Rated Impulse Withstand Voltage (Uimp) | 4 kV |
| Input Voltage Type | AC |
| Rated Current (In) | 16 A |
| Rated Residual Current | 30 mA |
| Rated Short-Circuit Capacity | 6 kA |
| Rated Conditional Short-Circuit Current (Inc) | 10 kA |
| Rated Frequency (f) | 50 / 60 Hz |
| Power Loss | Average per Pole 2.3 W |
| Phase Pole 3.4 W | |
| Neutral Pole 1.2 W | |
| Total 4.5 W | |
| Overvoltage Category | III |
| Material Compliance | |
| RoHS Declaration | 9AKK106713A5588 |
| RoHS Information | Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019 |
| RoHS Date | 20211115 |
| REACH Declaration | 9AKK108467A9482 |
| REACH Information | True - contains substances > 0.1 mass percentage |
| REACH Date | 20240429 |
| Conflict Minerals Reporting Template (CMRT) | 9AKK108468A3363 |
| WEEE Category | 5. Small Equipment (No External Dimension More Than 50 cm) |
| WEEE B2C / B2B | Business To Consumer |
| Environmental | |
| Ambient Air Temperature | Operation -25 … 55 °C |
| Reference Ambient Air Temperature | 30 °C |
| Degree of Protection | IP20 |
| IP40 | |
| Pollution Degree | 2 |
| Environmental Conditions | 28 cycles |
| with 55 °C / 90-96 % | |
| and 25 °C / 95-100 % | |
| Resistance to Vibrations | 20 Cycles with Load 0.8 In: 1g or 1mm 50 … 150 … 5 Hz |
| Resistance to Shock acc. to IEC 60068-2-27 | 25g 2 shocks 13 ms |
| Environmental Information | 2CSC422002K2701 |
| Dimensions | |
| Width in Number of Modular Spacings | 2 |
| Product Net Width | 35 mm |
| Product Net Height | 85 mm |
| Product Net Depth / Length | 69 mm |
| Product Net Weight | 200 g |
| Built-In Depth (t2) | 69 mm |
| Engineering | |
| EPLAN Data | 9AAC554444_EPLAN |
| Ordering | |
| Package Level 1 Units | box 1 piece |
| Package Level 1 Gross Weight | 225 g |
| E-Number (Finland) | 3211236 |
| E-Number (Sweden) | 2100485 |
| Certificates and Declarations | |
| ABS Certificate | 9AKK107991A2823 |
| CB Certificate | 9AKK107492A6060 |
| CCC Certificate | 9AKK107492A6067 |
| Declaration of Conformity - CE | 9AKK106713A5588 |
| DNV GL Certificate | 9AKK107680A3457 |
| 9AKK107680A3456 | |
| EAC Certificate | 9AKK107492A6071 |
| 9AKK107991A7755 | |
| GOST Certificate | 9AKK107992A1640 |
| KEMA Certificate | 9AKK107492A6076 |
| ÖVE Certificate | 9AKK107492A6085 |
| RMRS Certificate | 9AKK107680A3454 |
| 9AKK107680A3455 | |
| VDE Certificate | 9AKK107492A6092 |
| Installation | |
| Instructions and Manuals | 9AKK107492A6006 |
| Mounting Type | DIN-Rail |
| Mounting Position | Any |
| Popular Downloads | |
| Data Sheet, Technical Information | 9AKK107492A6187 |
| External Classifications and Standards | |
| ETIM 9 | EC000905 - Earth leakage circuit breaker |
| ETIM 10 | EC000905 - Earth leakage circuit breaker |
| UNSPSC | 39121601 |
| eClass | V11.0 : 27142207 |
| IDEA Granular Category Code (IGCC) | 4875 >> Residual current circuit breaker (RCCB) |
| Object Classification Code | F |
| Standards | IEC/EN 61009-1, IEC/EN 61009-2-1 |