ABB 2CSR255180R1404 2CSR255180R1404 ABB I.com.DS200 1p+N C 40A 10kA 30mA View larger
Images are for illustrative purposes only. Please refer to data sheet for details

2CSR255180R1404 ABB I.com.DS200 1p+N C 40A 10kA 30mA

2CSR255180R1404

255180

ABB

1 Pcs.

I.com.DS200 1p+N C 40A 10kA 30mA Residual Current Circuit Breaker with Overcurrent Protection DS201 - 1P+N - Type A - 30 mA - 40 A - C

Automation > Earth leakage circuit breaker
Tertiary / Industrial

Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.

Request a Quote

Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.

Request Quote

Product Overview

Providing high-capacity circuit protection, the 2CSR255180R1404 ABB I.com.DS200 1p+N C 40A 10kA 30mA serves as a reliable residual current circuit breaker with integrated overcurrent protection. Engineers deploy this device in heavy-duty distribution panels to prevent system failures caused by overloads, short circuits, and ground faults. Pricing, availability and lead time are confirmed per enquiry through an RFQ.

  • ABB EcoSolutions: Yes
  • EcoSolutions Profile: 9AKK108470A2163
  • Recyclability Rate of the Product acc. to EN45555: Design for Closing Resource Loops - Standard EN45555 - 75.20 %
  • ABB Site Meeting Group Waste To Landfill Target: No non-hazardous waste is sent to a landfill
  • Sustainable Material Content in Packaging (wt. %): Recycled Cardboard - 98 %
  • Extended Product Lifetime: Product Durability
  • End Of Life Disassembling Instructions: 9AKK108469A2268
  • Environmental Product Declaration - EPD: 9AKK108468A5756
  • Type of Residual Current: Type A
  • Test Voltage (Ut): 170 ... 264 V
  • Dielectric Test Voltage: 2 kV
  • Rated Ultimate Short-Circuit Breaking Capacity (I cu ): 10 kA
  • Rated Residual Breaking Capacity (IΔm): EN 61009-1 6000 A
  • Rated Service Short-Circuit Breaking Capacity (I cs ): 7.5 kA
  • Power Supply Connection: Arbitrary
  • Contact Position Indication: Red ON / Green OFF

More info

▲
ABB EcoSolutions
ABB EcoSolutionsYes
EcoSolutions Profile9AKK108470A2163
Recyclability Rate of the Product acc. to EN45555Design for Closing Resource Loops - Standard EN45555 - 75.20 %
ABB Site Meeting Group Waste To Landfill TargetNo non-hazardous waste is sent to a landfill
UL 2799 Zero Waste To Landfill Validation available
Sustainable Material Content in Packaging (wt. %)Recycled Cardboard - 98 %
Recycled Paper - 00 %
Chemically Recycled Polymer - 00 %
Extended Product LifetimeProduct Durability
End Of Life Disassembling Instructions9AKK108469A2268
Environmental Product Declaration - EPD9AKK108468A5756
Technical
Type of Residual CurrentType A
Test Voltage (Ut)170 ... 264 V
Dielectric Test Voltage2 kV
Rated Ultimate Short-Circuit Breaking Capacity (Icu)10 kA
Rated Residual Breaking Capacity (IΔm)EN 61009-1 6000 A
IEC 61009-1 4500 A
Rated Service Short-Circuit Breaking Capacity (Ics)7.5 kA
Rated Service Short-Circuit Breaking Capacity, in % of Icu (Ics)6 kA
Power Supply ConnectionArbitrary
Contact Position IndicationRed ON / Green OFF
Energy Limiting Class3
Electrical Endurance10000 cycle
Mechanical Endurance20000 cycle
Number of Protected Poles1
Number of Poles1P+N
Number of Modular Spacings per DIN Rail2
Fault IndicationBlue Flag on Toggle
Operating CharacteristicInstantaneous
Position of Neutral TerminalsRight
Tightening Torque2.8 N·m
Accessory TypeAuxiliary contact, Signal contact / auxiliary contact, Shunt trip, Auxiliary contact for bottom fitting, Overvoltage release, Motor operating device
Actuator TypeToggle - Insulation group II, Black RAL 9005, sealable in ON-OFF positions
Earthing Switch TypeUndelayed
Housing TypeInsulation group I - II, RAL 7035
Screw Terminal TypeFailsafe Bi-directional Cylinder-lift Terminal
Accessories AvailableYes
Number of Batteries0
Connecting CapacityBusbar 10 ... 10 mm²
Stranded 0.75 ... 25 mm²
Flexible with Ferrule 0.75 ... 16 mm²
Flexible 0.75 ... 16 mm²
Rated Cross-Section1 - Solid-Core 0.75 … 25 mm²
4 - Multi-Wired 0.75 … 16 mm²
Wire Stripping Length12 mm
Terminal TypeScrew Terminals
Electrical
Tripping CharacteristicC
Rated Operational Voltageacc. to IEC 60898-1 240 V
Rated Insulation Voltage (Ui)acc. to IEC/EN 60664-1 500 V
Rated Impulse Withstand Voltage (Uimp)4 kV
Input Voltage TypeAC
Rated Current (In)40 A
Rated Residual Current30 mA
Rated Short-Circuit Capacity6 kA
Rated Conditional Short-Circuit Current (Inc)10 kA
Rated Frequency (f)50 / 60 Hz
Power LossAverage per Pole 4.6 W
Phase Pole 5.0 W
Neutral Pole 4.1 W
Total 9.1 W
Overvoltage CategoryIII
Material Compliance
RoHS Declaration9AKK106713A5588
RoHS InformationFollowing EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
RoHS Date20211115
REACH Declaration9AKK108467A9482
REACH InformationTrue - contains substances > 0.1 mass percentage
REACH Date20240429
Conflict Minerals Reporting Template (CMRT)9AKK108468A3363
WEEE Category5. Small Equipment (No External Dimension More Than 50 cm)
WEEE B2C / B2BBusiness To Consumer
Environmental
Ambient Air TemperatureOperation -25 … 55 °C
Reference Ambient Air Temperature30 °C
Degree of ProtectionIP20
IP40
Pollution Degree2
Environmental Conditions28 cycles
with 55 °C / 90-96 %
and 25 °C / 95-100 %
Resistance to Vibrations20 Cycles with Load 0.8 In: 1g or 1mm 50 … 150 … 5 Hz
Resistance to Shock acc. to IEC 60068-2-2725g 2 shocks 13 ms
Environmental Information2CSC422002K2701
Dimensions
Width in Number of Modular Spacings2
Product Net Width35 mm
Product Net Height85 mm
Product Net Depth / Length69 mm
Product Net Weight200 g
Built-In Depth (t2)69 mm
Engineering
EPLAN Data9AAC554444_EPLAN
Ordering
Package Level 1 Unitsbox 1 piece
Package Level 1 Gross Weight225 g
E-Number (Finland)3211160
E-Number (Sweden)2100439
Certificates and Declarations
ABS Certificate9AKK107991A2823
CB Certificate9AKK107492A6060
CCC Certificate9AKK107492A6067
Declaration of Conformity - CE9AKK106713A5588
DNV GL Certificate9AKK107680A3457
9AKK107680A3456
EAC Certificate9AKK107492A6071
9AKK107991A7755
GOST Certificate9AKK107992A1640
KEMA Certificate9AKK107492A6076
ÖVE Certificate9AKK107492A6085
RMRS Certificate9AKK107680A3454
9AKK107680A3455
SEV Certificate9AKK107680A1558
9AKK107680A1560
VDE Certificate9AKK107492A6092
Installation
Instructions and Manuals9AKK107492A6006
Mounting TypeDIN-Rail
Mounting PositionAny
Popular Downloads
Data Sheet, Technical Information9AKK107492A6187
External Classifications and Standards
ETIM 9EC000905 - Earth leakage circuit breaker
ETIM 10EC000905 - Earth leakage circuit breaker
UNSPSC39121601
eClassV11.0 : 27142207
IDEA Granular Category Code (IGCC)4875 >> Residual current circuit breaker (RCCB)
Object Classification CodeF
StandardsIEC/EN 61009-1, IEC/EN 61009-2-1

Product Datasheet

Electrica Online Product Datasheet Prepared from the current product description, catalog data and structured technical attributes.