View larger
2CSR255163R1064 ABB I.com.DS301C 1p+N C 6A A 10kA 30mA
2CSR255163R1064
255163
ABB
1 Pcs.
Automation > Earth leakage circuit breaker
Tertiary / Industrial
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
An Abb 2CSR255163R1064 terminal and installation material component provides secure structural routing and mechanical organization for electrical distribution components within modular enclosures. Installers rely on these specialized accessories to streamline internal panel wiring and ensure compliant busbar installations. Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- GJF1101903R0004: SA1E Terminals and Installation Material
- GJF1101903R0002: SA2 Terminals and Installation Material
- GJF1109999R0001: SA2I Terminals and Installation Material
- GJF1101903R0003: SA3 Terminals and Installation Material
- 2CDL210331R1012: PSc 1/24/10 N Busbar
- 2CDL210331R1060: PSc 1/120/10 N Busbar
- 2CDL230331R1012: PSc 3/24/10 N Busbar
- 2CDL230331R1060: PSc 3/120/10 N Busbar
- 2CDL200331R0003: PSc-END End Cap
- 2CDL200331R0013: BSKc Accessories for PSc Busbars
- 2CDL200001R2506: AST25/27QS Feeder Terminal
More info
▲- Extended Product Type:
- DS301C C6 A30
- Product ID:
- 2CSR255163R1064
- EAN:
- 8012542360957
- Catalog Description:
- DS301C C6 A30 Residual Current Circuit Breaker with Overcurrent Protection
- Long Description:
- The DS301C series is a 1P+N RCBO in one module width for the protection of end user single-phase circuits against overload and short-circuit currents, protection against the effects of sinusoidal alternating and direct pulsating earth fault currents, protection against indirect contacts and additional protection against direct contacts (with sensitivity = 30 mA)
Accessories
| Identifier | Description | Type | Qty | Unit Of Measure |
|---|---|---|---|---|
| GJF1101903R0004 | SA1E Terminals and Installation Material | SA1E | 1 | piece |
| GJF1101903R0002 | SA2 Terminals and Installation Material | SA2 | 1 | piece |
| GJF1109999R0001 | SA2I Terminals and Installation Material | SA2I | 1 | piece |
| GJF1101903R0003 | SA3 Terminals and Installation Material | SA3 | 1 | piece |
| 2CDL210331R1012 | PSc 1/24/10 N Busbar | PSc 1/24/10 N | 1 | piece |
| 2CDL210331R1060 | PSc 1/120/10 N Busbar | PSc 1/120/10 N | 1 | piece |
| 2CDL230331R1012 | PSc 3/24/10 N Busbar | PSc 3/24/10 N | 1 | piece |
| 2CDL230331R1060 | PSc 3/120/10 N Busbar | PSc 3/120/10 N | 1 | piece |
| 2CDL200331R0003 | PSc-END End Cap | PSc-END | 1 | piece |
| 2CDL200331R0013 | BSKc Accessories for PSc Busbars | BSKc | 1 | piece |
| 2CDL200001R2506 | AST25/27QS Feeder Terminal | AST25/27QS | 1 | piece |
Technical
- Standards:
- IEC/EN 61009-1
IEC/EN 61009-2-1
- Tripping Characteristic:
- C
- Type of Residual Current:
- A type
- Rated Operational Voltage:
- 230 / 240 V AC
- Rated Insulation Voltage (Ui):
- 500 V
- Test Voltage (Ut):
- 170 ... 264 V
- Rated Impulse Withstand Voltage (Uimp):
- 4 kV
- Dielectric Test Voltage:
- 2.5 kV
- Primary Rated Impulse Withstand Voltage:
- 4 kV
- Input Voltage Type:
- AC
- Rated Current (In):
- 6 A
- Rated Residual Current:
- 30 mA
- Rated Short-Circuit Capacity:
- 6 kA
- Rated Ultimate Short-Circuit Breaking Capacity (Icu):
- 6 kA
- Rated Residual Breaking Capacity (IΔm):
- EN 61009-1 6000 A
IEC 61009-1 4500 A
- Rated Service Short-Circuit Breaking Capacity (Ics):
- 6 kA
- Leakage Current Type:
- A
- Rated Frequency (f):
- 50 … 60 Hz
- Power Loss:
- Average per Pole 0.78 W
Phase Pole 1.47 W
Neutral Pole 0.09 W
Total 1.56 W
- Power Supply Connection:
- Arbitrary
- Contact Position Indication:
- Red ON / Green OFF
- Energy Limiting Class:
- 3
- Electrical Endurance:
- 7000 cycle
- Mechanical Endurance:
- 7000 cycle
- Number of Poles:
- 1
- Number of Protected Poles:
- 1
- Number of Modular Spacings per DIN Rail:
- 1
- Fault Indication:
- Blue flag below toggle
- Operating Characteristic:
- Instantaneous
- Overvoltage Category:
- III
- Position of Neutral Terminals:
- Right
- Tightening Torque:
- 1.2 N·m
- Accessory Type:
- Busbar Psc series, Padlock
- Actuator Type:
- Toggle - Insulation group II, Black RAL 9005,
sealable in ON-OFF positions
- Housing Type:
- Insulation group I - II, RAL 7035
- Mounting Type:
- on DIN rail EN 60715 (35mm) by means of mounting clip
- Screw Terminal Type:
- Failsafe Bi-directional Cylinder-lift Terminal
- Mounting Position:
- Any
- Accessories Available:
- No
- Cable Size:
- 16 mm²
- Connecting Capacity:
- Busbar 10 ... 10 mm²
Rigid 1.5 ... 16 mm²
Flexible 1.5 ... 16 mm²
- Rated Cross-Section:
- 1 - Solid-Core 1.5 ... 16 mm²
4 - Multi-Wired 1.5 ... 10 mm²
- Wire Stripping Length:
- 10 mm
- Terminal Type:
- Screw Terminals
Environmental
- Ambient Temperature:
- -25 ... 55 °C
- Reference Ambient Air Temperature:
- 30 °C
- Degree of Protection:
- Terminals IP20
Housing IP40
- Pollution Degree:
- 2
- Environmental Conditions:
- 28 cycles
|with 55 °C / 90-96 %
|and 25 °C / 95-100 %
- Resistance to Vibrations acc. to IEC 60068-2-6:
- 0.1 mm or 1 g - 20 cycles at 5…150…5 Hz
- Resistance to Shock acc. to IEC 60068-2-27:
- 25g 2 shocks 13 ms
Dimensions
- Width in Number of Modular Spacings:
- 1
- Product Net Width:
- 0.0176m
- Product Net Height:
- 0.092m
- Product Net Depth / Length:
- 0.068m
- Product Net Weight:
- 0.110kg
- Built-In Depth (t2):
- 17.6 mm
Container Information
- Package Level 1 Units:
- box 1 piece
- Package Level 1 Width:
- 81 mm
- Package Level 1 Height:
- 25 mm
- Package Level 1 Depth / Length:
- 98 mm
- Package Level 1 Gross Weight:
- 0.127 kg
- Package Level 1 EAN:
- 8012542360957
Ordering
- Minimum Order Quantity:
- 1 piece
- Customs Tariff Number:
- 85363010
- E-Number (Finland):
- 3214083
- Country of Origin:
- Italy (IT)
Certificates and Declarations (Document Number)
- CB Certificate:
- 9AKK107991A9485
- CCC Certificate:
- 9AKK108467A0379
- CEBEC Certificate:
- 9AKK108466A9450
- Declaration of Conformity - CE:
- 9AKK108466A7779
- Instructions and Manuals:
- 9AKK107991A9407
- KEMA Certificate:
- 9AKK108467A0378
- RoHS Information:
- 9AKK108466A7779
- SEV Certificate:
- 9AKK108467A0377
- VDE Certificate:
- 9AKK108466A9224
Popular Downloads
- Data Sheet, Technical Information:
- 9AKK108466A9620
- Instructions and Manuals:
- 9AKK107991A9407
- Mechanical Drawings:
- 9AKK107991A9486
9AKK107991A9487
- EPLAN Macro:
- 9AKK108467A7418
Classifications
- ETIM 7:
- EC000905 - Earth leakage circuit breaker
- ETIM 8:
- EC000905 - Earth leakage circuit breaker
- EPLAN Catalog Tree:
- Electrical engineering / Protection devices / Ground fault current circuit breaker
- WEEE Category:
- 5. Small Equipment (No External Dimension More Than 50 cm)
- WEEE B2C / B2B:
- Business To Consumer
- CN8:
- 85363010
- eClass:
- V11.0 : 27142207
- Object Classification Code:
- F