ABB 2CSR245480R1164 2CSR245480R1164 ABB I.com.DS200L 1p+N C 16A A APR 6kA 30mA View larger
Images are for illustrative purposes only. Please refer to data sheet for details

2CSR245480R1164 ABB I.com.DS200L 1p+N C 16A A APR 6kA 30mA

2CSR245480R1164

245480

ABB

1 Pcs.

I.com.DS200L 1p+N C 16A A APR 6kA 30mA Residual Current Circuit Breaker with Overcurrent Protection DS201 L - 1P+N - 30 mA - 16 A - C - Type A APR

Automation > Earth leakage circuit breaker
Tertiary / Industrial

Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.

Request a Quote

Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.

Request Quote

Product Overview

Abb 2CSR245480R1164 is a residual current circuit breaker with overcurrent protection used in industrial and building automation panels to guard against electrical faults. This component combines short-circuit and earth-leakage tripping mechanisms to ensure comprehensive safety compliance. Pricing, availability and lead time are confirmed per enquiry through an RFQ.

  • ABB EcoSolutions: Yes
  • EcoSolutions Profile: 9AKK108470A2163
  • Recyclability Rate of the Product acc. to EN45555: Design for Closing Resource Loops - Standard EN45555 - 75.20 %
  • ABB Site Meeting Group Waste To Landfill Target: No non-hazardous waste is sent to a landfill
  • Sustainable Material Content in Packaging (wt. %): Recycled Cardboard - 98 %
  • Extended Product Lifetime: Product Durability
  • End Of Life Disassembling Instructions: 9AKK108469A2268
  • Environmental Product Declaration - EPD: 9AKK108468A5756
  • Type of Residual Current: Type A APR
  • Test Voltage (Ut): Minimum 170 V
  • Dielectric Test Voltage: 2 kV
  • Rated Ultimate Short-Circuit Breaking Capacity (I cu ): 6 kA
  • Rated Residual Breaking Capacity (IΔm): EN 61009-1 4500 A
  • Rated Service Short-Circuit Breaking Capacity (I cs ): 4.5 kA
  • Maximum Surge Current: 3 kA
  • Power Supply Connection: Arbitrary

More info

▲
ABB EcoSolutions
ABB EcoSolutionsYes
EcoSolutions Profile9AKK108470A2163
Recyclability Rate of the Product acc. to EN45555Design for Closing Resource Loops - Standard EN45555 - 75.20 %
ABB Site Meeting Group Waste To Landfill TargetNo non-hazardous waste is sent to a landfill
UL 2799 Zero Waste To Landfill Validation available
Sustainable Material Content in Packaging (wt. %)Recycled Cardboard - 98 %
Recycled Paper - 00 %
Chemically Recycled Polymer - 00 %
Extended Product LifetimeProduct Durability
End Of Life Disassembling Instructions9AKK108469A2268
Environmental Product Declaration - EPD9AKK108468A5756
Technical
Type of Residual CurrentType A APR
Test Voltage (Ut)Minimum 170 V
Maximum 264 V
Dielectric Test Voltage2 kV
Rated Ultimate Short-Circuit Breaking Capacity (Icu)6 kA
Rated Residual Breaking Capacity (IΔm)EN 61009-1 4500 A
IEC 61009-1 4500 A
Rated Service Short-Circuit Breaking Capacity (Ics)4.5 kA
Maximum Surge Current3 kA
Power Supply ConnectionArbitrary
Contact Position IndicationRed ON / Green OFF
Energy Limiting Class3
Electrical Endurance10000 cycle
Mechanical Endurance20000 cycle
Number of Protected Poles1
Number of Poles1P+N
Number of Modular Spacings per DIN Rail2
Fault IndicationBlue Flag on Toggle
Operating Characteristic10ms Delay (High Immunity)
Position of Neutral TerminalsRight
Tightening Torque2.8 N·m
Accessory TypeAuxiliary contact, Signal contact / auxiliary contact, Shunt trip, Auxiliary contact for bottom fitting, Overvoltage release, Motor operating device
Actuator TypeToggle - Insulation group II, Black RAL 9005, sealable in ON-OFF positions
Housing TypeInsulation group I - II, RAL 7035
Screw Terminal TypeFailsafe Bi-directional Cylinder-lift Terminal
Accessories AvailableYes
Surge Immunity acc. to IEC 61000-4-53000 A
Number of Batteries0
Connecting CapacityBusbar 10 ... 10 mm²
Stranded 0.75 ... 25 mm²
Flexible with Ferrule 0.75 ... 16 mm²
Flexible 0.75 ... 16 mm²
Wire Stripping Length12 mm
Terminal TypeScrew Terminals
Electrical
Tripping CharacteristicC
Rated Operational Voltageacc. to IEC 60898-1 240 V
Rated Insulation Voltage (Ui)acc. to IEC/EN 60664-1 500 V
Rated Impulse Withstand Voltage (Uimp)4 kV
Input Voltage TypeAC
Rated Current (In)16 A
Rated Residual Current30 mA
Rated Short-Circuit Capacity4.5 kA
Rated Conditional Short-Circuit Current (Inc)6 kA
Rated Frequency (f)50 / 60 Hz
Power LossAverage per Pole 2.3 W
Phase Pole 3.4 W
Neutral Pole 1.2 W
Total 4.5 W
Overvoltage CategoryIII
Material Compliance
RoHS Declaration9AKK106713A5588
RoHS InformationFollowing EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
RoHS Date20211115
REACH Declaration9AKK108467A9482
REACH InformationTrue - contains substances > 0.1 mass percentage
REACH Date20240429
Conflict Minerals Reporting Template (CMRT)9AKK108468A3363
WEEE Category5. Small Equipment (No External Dimension More Than 50 cm)
WEEE B2C / B2BBusiness To Consumer
Environmental
Ambient Air TemperatureOperation -25 … 55 °C
Reference Ambient Air Temperature30 °C
Degree of ProtectionIP20
IP40
Pollution Degree2
Environmental Conditions28 cycles
with 55 °C / 90-96 %
and 25 °C / 95-100 %
Resistance to Vibrations20 Cycles with Load 0.8 In: 1g or 1mm 50 … 150 … 5 Hz
Resistance to Shock acc. to IEC 60068-2-2725g 2 shocks 13 ms
Environmental Information2CSC422002K2701
Dimensions
Width in Number of Modular Spacings2
Product Net Width35 mm
Product Net Height85 mm
Product Net Depth / Length69 mm
Product Net Weight200 g
Built-In Depth (t2)69 mm
Engineering
EPLAN Data9AAC554444_EPLAN
Ordering
Package Level 1 Unitsbox 1 piece
Package Level 1 Gross Weight225 g
Certificates and Declarations
CB Certificate9AKK107492A6062
CCC Certificate9AKK107492A6068
Declaration of Conformity - CE9AKK106713A5588
EAC Certificate9AKK107492A6071
9AKK107991A7755
GOST Certificate9AKK107992A1640
IMQ Certificate9AKK107492A6073
Installation
Instructions and Manuals9AKK107492A6006
Mounting TypeDIN-Rail
Mounting PositionAny
Popular Downloads
Data Sheet, Technical Information9AKK107492A6187
External Classifications and Standards
ETIM 9EC000905 - Earth leakage circuit breaker
ETIM 10EC000905 - Earth leakage circuit breaker
UNSPSC39121601
eClassV11.0 : 27142207
Object Classification CodeF
StandardsIEC/EN 61009-1, IEC/EN 61009-2-1