View larger
2CSR245080R1324 ABB I.com.DS200L 1p+N C 32A AC 6kA 30mA
2CSR245080R1324
245080
ABB
1 Pcs.
Automation > Earth leakage circuit breaker
Tertiary / Industrial
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
ABB residual current circuit breaker with overcurrent protection 2CSR245080R1324 provides reliable isolation against thermal overloads and earth leakage currents in electrical switchboards. These modular devices ensure comprehensive safety compliance for distribution circuits. Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Number of poles (total) (EF008618): 2
- Number of protected poles (EF005548): 1
- Rated voltage (EF000228): 240 V
- Rated insulation voltage Ui (EF001366): 500 V
- Rated impulse withstand voltage Uimp (EF011980): 4 kV
- Rated current (EF000227): 32 A
- Rated fault current (EF002358): 0.03 A
- Leakage current type (EF002560): AC
- Current limiting class (EF002568): 3
- Disconnection characteristic (EF012587): Undelayed
- Surge current capacity (EF002564): 0 kA
- Voltage type (EF000187): AC
- Frequency (EF005455): 50/60 Hz
- Release characteristic (EF000889): C
- Concurrently switching neutral conductor (EF005997): Yes
- With interlocking device (EF007385): No
More info
▲b'
General Information
DS201 L C32 AC30
2CSR245080R1324
8012542637615
DS201 L C32 AC30 - RCBO
The DS201 series is a 1P+N RCBO in two-modules width for the protection of end user single-phase circuits against overload and short-circuit currents; protection against the effects of sinusoidal alternating earth fault currents; protection against indirect contacts and additional protection against direct contacts (with sensitivity = 30 mA).
Technical
IEC/EN 61009-1, IEC/EN 61009-2-1
AC type
2
1
32 A
0.03 A
230 V
500 V
III
2
170 … 264 V
50 … 60 Hz
4.5 kA
6 kA
4.5 kA
EN 61009-1 4500 A
IEC 61009-1 4500 A
4 kV
2.5 kV
C
3
Insulation group I - II, RAL 7035
Toggle - Insulation group II, Black RAL 9005,sealable in ON-OFF positions
Red ON / Green OFF
Blue flag on toggle
10000 cycle
20000 cycle
Terminals IP20
Housing IP40
25g / 2 shocks / 13 ms
0.1 mm or 1 g - 20 cycles at 5…150…5 Hz
28 cycles
with 55 °C / 90-96 %
and 25 °C / 95-100 %
30 °C
Screw Terminals
Failsafe Bi-directional Cylinder-lift Terminal
25 mm²
Busbar 10/10 mm²
Stranded 0.75 … 25 mm²
Flexible with Ferrule 0.75 … 16 mm²
Flexible 0.75 … 16 mm²
2.8 N·m
12 mm
on DIN rail EN 60715 (35mm) by means of mounting clip
Any
Arbitrary
Right
6.4 W
2
Auxiliary contact
Signal contact / auxiliary contact
Shunt trip
Auxiliary contact for bottom fitting
Undervoltage release
Overvoltage release
Motor operating device
Environmental
Operation -25...55 °C
Technical UL/CSA
0.03 A
Dimensions
0.035 m
0.085 m
0.069 m
0.200 kg
Container Information
box 1 piece
40 mm
106 mm
80 mm
225 g
8012542637615
5 piece
200 mm
106 mm
80 mm
1125 g
8012542566816
Ordering
1 piece
85363030
Certificates and Declarations (Document Number)
Popular Downloads
Classifications
Q
EC000905 - Earth leakage circuit breaker
EC000905 - Earth leakage circuit breaker