View larger
2CSF202325R1630 ABB I. diff. F202 F-63/0.03 2p 63 F 30mA
2CSF202325R1630
202325
ABB
1 Pcs.
Automation > Residual current circuit breaker (RCCB)
Industrial
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
Monitoring electrical leakage currents in automation panels is efficiently managed by this ABB differential current interrupter, catalog number 2CSF202325R1630. This safety component prevents potential electrical hazards by interrupting circuits instantly upon detecting current imbalances between active conductors.
Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- ABB EcoSolutions: Yes
- EcoSolutions Profile: 9AKK108469A3794
- Recyclability Rate of the Product acc. to EN45555: Design for Closing Resource Loops - Standard EN45555 - 82.05 %
- ABB Site Meeting Group Waste To Landfill Target: No non-hazardous waste is sent to a landfill
- Sustainable Material Content in Packaging (wt. %): Recycled Paper - 0 %
- Extended Product Lifetime: Product Durability
- Offered with Takeback Services: Take Back for Recycling
- End Of Life Disassembling Instructions: 9AKK108470A1748
- Environmental Product Declaration - EPD: 9AKK108469A9642
- Type of Residual Current: Type F
- Test Voltage (Ut): 170-259 V
- Maximum Surge Current: 4 kA
- Leakage Current Type: F
- Power Supply Connection: Arbitrary
- Electrical Endurance: 10000 cycle
- Mechanical Endurance: 20000 cycle
More info
▲| ABB EcoSolutions | |
|---|---|
| ABB EcoSolutions | Yes |
| EcoSolutions Profile | 9AKK108469A3794 |
| Recyclability Rate of the Product acc. to EN45555 | Design for Closing Resource Loops - Standard EN45555 - 82.05 % |
| ABB Site Meeting Group Waste To Landfill Target | No non-hazardous waste is sent to a landfill |
| UL 2799 Zero Waste To Landfill Validation available | |
| Sustainable Material Content in Packaging (wt. %) | Recycled Paper - 0 % |
| Recycled Paper - 3.91 % | |
| Recycled Cardboard - 29.08 % | |
| Recycled Cardboard - 61.23 % | |
| Recycled Cardboard - 2.66 % | |
| Extended Product Lifetime | Product Durability |
| Offered with Takeback Services | Take Back for Recycling |
| End Of Life Disassembling Instructions | 9AKK108470A1748 |
| Environmental Product Declaration - EPD | 9AKK108469A9642 |
| Technical | |
| Type of Residual Current | Type F |
| Test Voltage (Ut) | 170-259 V |
| Maximum Surge Current | 4 kA |
| Leakage Current Type | F |
| Power Supply Connection | Arbitrary |
| Electrical Endurance | 10000 cycle |
| Mechanical Endurance | 20000 cycle |
| Number of Poles | 2P |
| Number of Modular Spacings per DIN Rail | 2 |
| Operating Characteristic | 10ms Delay (High Immunity) |
| Tightening Torque | 2.8 N·m |
| Accessory Type | Auxiliary contact |
| Auxiliary/Signal contact | |
| Shunt trip | |
| Undervoltage release | |
| Overvoltage release | |
| Motor Operating Device | |
| Bottom fitting auxiliary contact | |
| Autoreclosing Unit | |
| Home automatic resetting unit | |
| Screw Terminal Type | Failsafe Bi-directional Cylinder-lift Terminal |
| Cage Terminal | |
| Failsafe Biconnect Fork Top/Bottom | |
| Failsafe Biconnect Fork Bottom | |
| Options Provided | None |
| Accessories Available | Yes |
| Connecting Capacity | Busbar 10 mm² |
| Rigid 25 ... 25 mm² | |
| Flexible 25 ... 25 mm² | |
| Rated Cross-Section | 4 - Multi-Wired 0...25 mm² |
| 1 - Solid-Core 25...25 mm² | |
| Wire Stripping Length | 12 mm |
| Terminal Type | Screw Terminals |
| Frequency Range (frange) | Residual Current 1 ... 1000 Hz |
| Electrical | |
| Rated Voltage (Ur) | 230 V |
| Rated Operational Voltage | 230 V |
| Rated Insulation Voltage (Ui) | 500 V |
| Rated Impulse Withstand Voltage (Uimp) | 4 kV |
| Input Voltage Type | AC |
| Rated Current (In) | 63 A |
| Rated Residual Current | 30 mA |
| Rated Conditional Short-Circuit Current (Inc) | 10 kA |
| Frequency (f) | 50/60 Hz |
| Rated Frequency (f) | 50 … 60 Hz |
| Power Loss | at Rated Operating Conditions per Pole 3.2 W |
| Total 6.4 W | |
| Design | |
| RAL Number | RAL 7035 - Light Grey |
| Number of Modules | 2 |
| Material Compliance | |
| RoHS Declaration | 9AKK106713A5612 |
| RoHS Information | Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019 |
| RoHS Date | 20211115 |
| REACH Declaration | 9AKK108467A9482 |
| REACH Information | True - contains substances > 0.1 mass percentage |
| REACH Date | 20240429 |
| Conflict Minerals Reporting Template (CMRT) | 9AKK108468A3363 |
| SCIP | 18f132b0-8f03-4611-9c59-dba03cc369bf Italy |
| WEEE Category | 5. Small Equipment (No External Dimension More Than 50 cm) |
| WEEE B2C / B2B | Business To Consumer |
| Environmental | |
| Ambient Air Temperature | Operation -25 ... 55 °C |
| Storage -40 ... 70 °C | |
| Degree of Protection | Terminals IP20 |
| Housing IP40 | |
| Pollution Degree | 2 |
| Resistance to Vibrations | 20 Cycles with Load 0.8 In: 1g or 1mm 5 … 150 … 5 Hz |
| Resistance to Shock acc. to IEC 60068-2-27 | 25g 2 shocks 13 ms |
| Environmental Information | Refer to RoHS |
| Dimensions | |
| Width in Number of Modular Spacings | 2 |
| Product Net Width | 35 mm |
| Product Net Height | 85 mm |
| Product Net Depth / Length | 69 mm |
| Product Net Weight | 225 g |
| Built-In Depth (t2) | 69 mm |
| Ordering | |
| Package Level 1 Units | box 1 piece |
| Package Level 1 Gross Weight | 0.235 kg |
| Certificates and Declarations | |
| Declaration of Conformity - CE | 9AKK106713A5612 |
| NF Certificate | 9AKK108471A9257 |
| Installation | |
| Instructions and Manuals | 9AKK107991A6127 |
| Mounting Type | DIN-Rail |
| Mounting Position | Any |
| Popular Downloads | |
| Data Sheet, Technical Information | 9AKK107991A8329 |
| External Classifications and Standards | |
| ETIM 9 | EC000003 - Residual current circuit breaker (RCCB) |
| ETIM 10 | EC000003 - Residual current circuit breaker (RCCB) |
| UNSPSC | 39121601 |
| eClass | V11.0 : 27142201 |
| IDEA Granular Category Code (IGCC) | 4875 >> Residual current circuit breaker (RCCB) |
| Object Classification Code | F |
| Standards | IEC/EN 61008-1, IEC/EN 61008-2-1, IEC/EN 62423 |