View larger
2CSA275901R9255 ABB S-ARC1MB25 Detect. Arch + Int. Autom.
2CSA275901R9255
275901
ABB
1 Pcs.
Automation > Miniature circuit breaker (MCB) with auxiliary device
Industrial
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
An ABB arc fault detection device (2CSA275901R9255 ABB S-ARC1MB25 Detect. Arch + Int. Autom.) protects electrical distribution systems by detecting unintended electrical arcs and interrupting the circuit to prevent potential fires. These units integrate advanced monitoring technology to safeguard residential and industrial branch circuits. Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- ABB EcoSolutions: Yes
- EcoSolutions Profile: 9AKK108471A1002
- Recyclability Rate of the Product acc. to EN45555: Design for Closing Resource Loops - Standard EN45555 - 81.91 %
- ABB Site Meeting Group Waste To Landfill Target: No non-hazardous waste is sent to a landfill
- Extended Product Lifetime: Product Durability
- End Of Life Disassembling Instructions: 9AKK108469A4799
- Environmental Product Declaration - EPD: 9AKK108468A8866
- Dielectric Test Voltage: 2.5 kV
- Rated Ultimate Short-Circuit Breaking Capacity (I cu ): 10 kA
- Rated Service Short-Circuit Breaking Capacity (I cs ): 7.5 kA
- Power Supply Connection: Arbitrary
- Contact Position Indication: Red ON / Green OFF
- Energy Limiting Class: 3
- Electrical Endurance: 10000 cycle
- Mechanical Endurance: 20000 cycle
- Number of Protected Poles: 1
More info
▲| ABB EcoSolutions | |
|---|---|
| ABB EcoSolutions | Yes |
| EcoSolutions Profile | 9AKK108471A1002 |
| Recyclability Rate of the Product acc. to EN45555 | Design for Closing Resource Loops - Standard EN45555 - 81.91 % |
| ABB Site Meeting Group Waste To Landfill Target | No non-hazardous waste is sent to a landfill |
| UL 2799 Zero Waste To Landfill Validation available | |
| Extended Product Lifetime | Product Durability |
| End Of Life Disassembling Instructions | 9AKK108469A4799 |
| Environmental Product Declaration - EPD | 9AKK108468A8866 |
| Technical | |
| Dielectric Test Voltage | 2.5 kV |
| Rated Ultimate Short-Circuit Breaking Capacity (Icu) | 10 kA |
| Rated Service Short-Circuit Breaking Capacity (Ics) | 7.5 kA |
| Power Supply Connection | Arbitrary |
| Contact Position Indication | Red ON / Green OFF |
| Energy Limiting Class | 3 |
| Electrical Endurance | 10000 cycle |
| Mechanical Endurance | 20000 cycle |
| Number of Protected Poles | 1 |
| Number of Poles | 1P+N |
| Number of Modular Spacings per DIN Rail | 2 |
| Operating Characteristic | Instantaneous |
| Position of Neutral Terminals | Right |
| Tightening Torque | 2.8 N·m |
| Accessory Type | Auxiliary contact |
| Auxiliary/Signal contact | |
| Shunt trip | |
| Undervoltage release | |
| Overvoltage release | |
| Actuator Type | Toggle - Insulation group II,Orange RAL 2004, sealable in ON-OFF-positions |
| Housing Type | Insulation group I, RAL 7035 |
| Screw Terminal Type | Failsafe Bi-directional Cylinder-lift Terminal |
| Includes | Fire protection switch |
| Accessories Available | Yes |
| Mounting Position of Accessories | Right |
| Number of Batteries | 0 |
| Connecting Capacity | Busbar 10 mm² |
| Rigid 1…25 mm² | |
| Flexible 1…16 mm² | |
| Wire Stripping Length | 12 mm |
| Terminal Type | Screw Terminals |
| Electrical | |
| Tripping Characteristic | B |
| Rated Operational Voltage | 230...240 V AC |
| Rated Insulation Voltage (Ui) | 500 V |
| Rated Impulse Withstand Voltage (Uimp) | 4 kV |
| Input Voltage Type | AC |
| Rated Current (In) | 25 A |
| Rated Short-Circuit Capacity | 10 kA |
| Rated Frequency (f) | 50 Hz |
| Power Loss | 3.5 W |
| Overvoltage Category | III |
| Design | |
| Number of Modules | 2 |
| Material Compliance | |
| RoHS Declaration | 9AKK107045A1564 |
| RoHS Information | Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019 |
| RoHS Date | 20170621 |
| REACH Declaration | 9AKK108467A9482 |
| REACH Information | True - contains substances > 0.1 mass percentage |
| REACH Date | 20240429 |
| Conflict Minerals Reporting Template (CMRT) | 9AKK108468A3363 |
| WEEE Category | 5. Small Equipment (No External Dimension More Than 50 cm) |
| WEEE B2C / B2B | Business To Consumer |
| Environmental | |
| Ambient Air Temperature | Operation -25 ... 55 °C |
| Storage -40 ... 70 °C | |
| Reference Ambient Air Temperature | 30 °C |
| Degree of Protection | Terminals IP20 |
| Housing IP40 | |
| Pollution Degree | 2 |
| Environmental Conditions | 28 cycles |
| with 55 °C / 90-96 % | |
| and 25 °C / 95-100 % | |
| Resistance to Vibrations | 20 Cycles with Load 0.8 In: 5g or 0.2mm 5 … 150 Hz |
| Resistance to Shock acc. to IEC 60068-2-27 | 30g 2 shocks 13 ms |
| Dimensions | |
| Width in Number of Modular Spacings | 2 |
| Product Net Width | 35 mm |
| Product Net Height | 85 mm |
| Product Net Depth / Length | 69 mm |
| Product Net Weight | 180 g |
| Built-In Depth (t2) | 69 mm |
| Dimension Diagram | 9AKK106930A8989 |
| Ordering | |
| Package Level 1 Units | box 1 piece |
| Package Level 1 Gross Weight | 0.200 kg |
| Certificates and Declarations | |
| Declaration of Conformity - CE | 9AKK107045A1563 |
| IMQ Certificate | 9AKK107045A4216 |
| KC Certificate | 9AKK108466A5925 |
| VDE Certificate | 9AKK107045A7202 |
| Installation | |
| Instructions and Manuals | 9AKK106930A8985 |
| 9AKK106930A8986 | |
| Mounting Type | DIN-Rail |
| Mounting Position | Any |
| Popular Downloads | |
| Data Sheet, Technical Information | 2CDC420032D0201 |
| Mechanical Drawings | 9AKK106930A8988 |
| 9AKK106930A8989 | |
| External Classifications and Standards | |
| ETIM 9 | EC002694 - Miniature circuit breaker (MCB) with auxiliary device |
| ETIM 10 | EC002694 - Miniature circuit breaker (MCB) with auxiliary device |
| eClass | V11.0 : 27141906 |
| Object Classification Code | F |
| Standards | IEC/EN 62606 |
| IEC/EN 60898-1 | |