Request QuoteProduct Overview
Designed for comprehensive circuit protection, this ABB 2CSA275103R1105 arc fault detection and residual current unit mitigates both electrical fires and shock hazards in electrical distribution networks. These combination devices offer streamlined protection for sensitive terminal circuits in residential and commercial buildings. Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Environmental Product Declaration - EPD: 9AKK108470A1707
- Type of Residual Current: Type A
- Test Voltage (Ut): 170 … 264 V
- Dielectric Test Voltage: 2.5 kV
- Rated Ultimate Short-Circuit Breaking Capacity (I cu ): 10 kA
- Rated Residual Breaking Capacity (IΔm): 6 kA
- Rated Service Short-Circuit Breaking Capacity (I cs ): 7.5 kA
- Power Supply Connection: Arbitrary
- Contact Position Indication: Red ON / Green OFF
- Energy Limiting Class: 3
- Electrical Endurance: 10000 cycle
- Mechanical Endurance: 20000 cycle
- Number of Protected Poles: 1
- Number of Poles: 1P+N
- Number of Modular Spacings per DIN Rail: 3
- Fault Indication: Blue Flag on Toggle
More info
▲| ABB EcoSolutions | |
|---|---|
| Environmental Product Declaration - EPD | 9AKK108470A1707 |
| Technical | |
| Type of Residual Current | Type A |
| Test Voltage (Ut) | 170 … 264 V |
| Dielectric Test Voltage | 2.5 kV |
| Rated Ultimate Short-Circuit Breaking Capacity (Icu) | 10 kA |
| Rated Residual Breaking Capacity (IΔm) | 6 kA |
| Rated Service Short-Circuit Breaking Capacity (Ics) | 7.5 kA |
| Power Supply Connection | Arbitrary |
| Contact Position Indication | Red ON / Green OFF |
| Energy Limiting Class | 3 |
| Electrical Endurance | 10000 cycle |
| Mechanical Endurance | 20000 cycle |
| Number of Protected Poles | 1 |
| Number of Poles | 1P+N |
| Number of Modular Spacings per DIN Rail | 3 |
| Fault Indication | Blue Flag on Toggle |
| Operating Characteristic | Instantaneous |
| Position of Neutral Terminals | Right |
| Tightening Torque | 2.8 N·m |
| Accessory Type | Auxiliary contact |
| Auxiliary/Signal contact | |
| Shunt trip | |
| Undervoltage release | |
| Overvoltage release | |
| Bottom fitting auxiliary contact | |
| Actuator Type | Toggle -Insulation group II, Orange RAL 2004, sealable in ON-OFF-positions |
| Housing Type | Insulation group I, RAL 7035 |
| Screw Terminal Type | Failsafe Bi-directional Cylinder-lift Terminal |
| Accessories Available | Yes |
| Mounting Position of Accessories | Right |
| Number of Batteries | 0 |
| Connecting Capacity | Busbar 10 mm² |
| Rigid 1…25 mm² | |
| Flexible 1…16 mm² | |
| Wire Stripping Length | 12 mm |
| Terminal Type | Screw Terminals |
| Electrical | |
| Tripping Characteristic | B |
| Rated Operational Voltage | 230...240 V AC |
| Rated Insulation Voltage (Ui) | 500 V |
| Rated Impulse Withstand Voltage (Uimp) | 4 kV |
| Input Voltage Type | AC |
| Rated Current (In) | 10 A |
| Rated Residual Current | 30 mA |
| Rated Short-Circuit Capacity | 10 kA |
| Rated Frequency (f) | 50 … 60 Hz |
| Power Loss | 1.8 W |
| Overvoltage Category | III |
| Design | |
| Number of Modules | 3 |
| Material Compliance | |
| RoHS Declaration | 9AKK107046A6530 |
| RoHS Information | Following EU Directive 2011/65/EU |
| RoHS Date | 20180903 |
| REACH Declaration | 9AKK108467A9482 |
| REACH Information | True - contains substances > 0.1 mass percentage |
| REACH Date | 20240429 |
| Conflict Minerals Reporting Template (CMRT) | 9AKK108468A3363 |
| WEEE Category | 5. Small Equipment (No External Dimension More Than 50 cm) |
| WEEE B2C / B2B | Business To Consumer |
| Environmental | |
| Ambient Air Temperature | Operation -25 ... 55 °C |
| Storage -40 ... 70 °C | |
| Reference Ambient Air Temperature | 30 °C |
| Degree of Protection | Terminals IP20 |
| Housing IP40 | |
| Pollution Degree | 2 |
| Environmental Conditions | 28 cycles |
| with 55 °C / 90-96 % | |
| and 25 °C / 95-100 % | |
| Resistance to Vibrations | 20 Cycles with Load 0.8 In: 5g or 0.2mm 5 … 150 Hz |
| Resistance to Shock acc. to IEC 60068-2-27 | 30g 2 shocks 13 ms |
| Dimensions | |
| Width in Number of Modular Spacings | 3 |
| Product Net Width | 52.5 mm |
| Product Net Height | 85 mm |
| Product Net Depth / Length | 69 mm |
| Product Net Weight | 240 g |
| Built-In Depth (t2) | 69 mm |
| Dimension Diagram | 9AKK107046A6174 |
| Engineering | |
| EPLAN Data | 9AAC190691_EPLAN |
| Ordering | |
| Package Level 1 Units | box 1 piece |
| Package Level 1 Gross Weight | 0.270 kg |
| E-Number (Finland) | 3211098 |
| E-Number (Norway) | 1683235 |
| Certificates and Declarations | |
| Declaration of Conformity - CE | 9AKK107046A6529 |
| IMQ Certificate | 9AKK107046A6177 |
| KC Certificate | 9AKK108466A5926 |
| VDE Certificate | 9AKK107046A6968 |
| Installation | |
| Instructions and Manuals | 9AKK107046A6173 |
| 9AKK106930A8986 | |
| Mounting Type | DIN-Rail |
| Mounting Position | Any |
| Popular Downloads | |
| Data Sheet, Technical Information | 9AKK107046A7200 |
| Mechanical Drawings | 9AKK107046A6174 |
| 9AKK107046A6175 | |
| External Classifications and Standards | |
| ETIM 9 | EC002695 - Earth leakage circuit breaker with auxiliary device |
| ETIM 10 | EC002695 - Earth leakage circuit breaker with auxiliary device |
| eClass | V11.0 : 27142213 |
| Object Classification Code | F |
| Standards | IEC/EN 62606 |
| IEC/EN 61009-1 | |
| IEC/EN 61009-2-1 | |