View larger
2CDE601102R0110 ABB Prot. EPD24-E4 1-10 Electronics
2CDE601102R0110
601102
ABB
1 Pcs.
Automation > Device circuit breaker
Other modular devices
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
The Abb 2CDE601102R0110 ABB Prot. EPD24-E4 1-10 Electronics is an electronic protection device designed to safeguard industrial control systems and sensitive electronics against overloads and short circuits. Units of this type are integrated into electrical distribution panels to provide selective channel protection and ensure continuous operational uptime for automated machinery. Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- Number of Auxiliary Contacts NO: 1
- Number of Channels: 4
- Signal Indication Fault (LED): Red
- Fault Reset: Manual
- Status Indicator: Yes
- Additional Information: Backup fuse for EPD24 not required
- Recommended Screw Driver: Screw Slot
- Accessories Available: Yes
- Output: Power MOSFET Switching Output (Positive Switching) without Galvanic Isolation
- Remarks: Parallel connection of outputs not permissible
- Electromagnetic Compatibility (EMC): Emission - Class B
- Wire Stripping Length: Auxiliary Circuit 8 mm
- Delay Time for Switching On: Cascaded After Power on with 24 VDC Channel 1 100 ms
- Operating Humidity (RH amb ): 96 hrs/95% RH/40 °C
- Operational Derating: Derating 60 °C ... 70 °C: 2 %/K per channel output
- Rated Current According to Temperature: 9AKK108468A1268
More info
▲| Technical | |
|---|---|
| Output Signal | Group signal output 13-14; Operating condition: 13; Potential-free normally open contact max. 30 V DC/200 mA, min. 10 V DC/1 mA. |
| Number of Auxiliary Contacts NO | 1 |
| Number of Channels | 4 |
| Signal Indication Fault (LED) | Red |
| Fault Reset | Manual |
| Remote | |
| Status Indicator | Yes |
| Additional Information | Backup fuse for EPD24 not required |
| Recommended Screw Driver | Screw Slot |
| Accessories Available | Yes |
| Output | Power MOSFET Switching Output (Positive Switching) without Galvanic Isolation |
| Remarks | Parallel connection of outputs not permissible |
| Electromagnetic Compatibility (EMC) | Emission - Class B |
| Immunity - Class A | |
| Wire Stripping Length | Auxiliary Circuit 8 mm |
| For N Terminals 8 mm | |
| Input Circuit 18 mm | |
| Output Circuit 10 mm | |
| Delay Time for Switching On | Cascaded After Power on with 24 VDC Channel 1 100 ms |
| Cascaded After Power on with 24 VDC Channel 2 200 ms | |
| Cascaded After Power on with 24 VDC Channel 3 300 ms | |
| Cascaded After Power on with 24 VDC Channel 4 400 ms | |
| Operating Humidity (RHamb) | 96 hrs/95% RH/40 °C |
| Operational Derating | Derating 60 °C ... 70 °C: 2 %/K per channel output |
| Rated Current According to Temperature | 9AKK108468A1268 |
| Undervoltage Trip Device | Hysteresis typ. 2 V |
| OFF at typ. Uin < 16 V DC | |
| ON at typ. Uin > 19 V DC | |
| Signal Indication Load Circuit > 80 % | Green / Orange |
| Electrical | |
| Tripping Characteristic | Electronic Time Controlled |
| Rated Voltage (Ur) | 24 V DC |
| Rated Insulation Voltage (Ui) | Output Circuit 30 V DC |
| Output Voltage (Uout) | typ. per 1 A: 0.012 V |
| Current Range | 1 A |
| 2 A | |
| 3 A | |
| 4 A | |
| 5 A | |
| 6 A | |
| 8 A | |
| 10 A | |
| 7 A | |
| 9 A | |
| Power Loss | at Rated Load 5.6 W |
| Design | |
| Housing Material | Moulded |
| RAL Number | RAL 7012 - Basalt Grey |
| Color | dark grey |
| Technical UL/CSA | |
| Connecting Capacity Auxiliary Circuit UL/CSA | Flexible 24-16 AWG |
| Rigid 24-16 AWG | |
| Material Compliance | |
| RoHS Declaration | 9AKK107492A1906 |
| RoHS Information | Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019 |
| RoHS Date | 20230404 |
| REACH Declaration | 9AKK107492A1906 |
| REACH Information | False - does not contain substances > 0.1 mass percentage |
| REACH Date | 20251028 |
| Conflict Minerals Reporting Template (CMRT) | 9AKK108468A3363 |
| WEEE Category | 5. Small Equipment (No External Dimension More Than 50 cm) |
| WEEE B2C / B2B | Business To Consumer |
| Environmental | |
| Ambient Air Temperature | Operation -25 ... +70 °C |
| Storage -40 ... +70 °C | |
| Degree of Protection | IP20 |
| Protection Class | Grounded or Insulated (Class III) |
| Pollution Degree | 2 |
| Resistance to Vibrations | 20 Cycles with Load 0.8 In: 2g 10 ... 500 ... 10 Hz |
| Dimensions | |
| Product Net Width | 25 mm |
| Product Net Height | 130 mm |
| Product Net Depth / Length | 108 mm |
| Product Net Weight | 0.175 kg |
| Dimension Diagram | 9AKK108467A0009 |
| Engineering | |
| EPLAN Data | 9AAC171943_EPLAN |
| Ordering | |
| Package Level 1 Units | box 1 piece |
| Package Level 1 Gross Weight | 0.303 kg |
| Certificates and Declarations | |
| CSA Certificate | 9AKK108468A2242 |
| cULus Certificate | 9AKK108468A2242 |
| cUR Certificate | 9AKK108467A1167 |
| Declaration of Conformity - CE | 9AKK108467A7547 |
| Declaration of Conformity - UKCA | 9AKK108468A0011 |
| Installation | |
| Instructions and Manuals | 9AKK108467A7088 |
| Mounting on DIN Rail | TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715 |
| Mounting Position | vertical |
| Popular Downloads | |
| Data Sheet, Technical Information | 9AKK108467A7088 |
| Time-Current Characteristic Curve | 9AKK108467A8028 |
| External Classifications and Standards | |
| ETIM 9 | EC003538 - Device circuit breaker |
| ETIM 10 | EC003538 - Device circuit breaker |
| UNSPSC | 39121601 |
| eClass | V11.0 : 27141901 |
| IDEA Granular Category Code (IGCC) | 4813 >> Circuit breakers |
| Object Classification Code | F |
| Standards | CSA 22.2 |
| UL 2367 recognized | |
| UL 508 listed | |
| Certification Agency | CSA |
| UL | |
| Standardization Body | UL |
| CSA | |