View larger
2CCG001318R0001
001318
ABB
1 Pcs.
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
| Technical | |
|---|---|
| Rated Operational Current (Ie) | 125 A |
| Rated Ultimate Short-Circuit Breaking Capacity (Icu) | (415 V AC) 50 kA |
| (440 V AC) 30 kA | |
| (500 V AC) 10 kA | |
| (690 V AC) 4.5 kA | |
| Rated Service Short-Circuit Breaking Capacity (Ics) | (240 / 415 V AC) 40 kA |
| Number of Protected Poles | 4 |
| Number of Poles | 4P |
| Number of Earth Leakage Circuit Breakers (ELCBs) | 1 |
| Operating Characteristic | Instantaneous |
| Release Type | B |
| Accessories Available | Yes |
| Electrical | |
| Short-Circuit Current Rating (SCCR) | 300 mA |
| Tripping Characteristic | B |
| Rated Operational Voltage | acc. to IEC 60947-2 690 V AC |
| Rated Current (In) | 125 A |
| Rated Residual Current | 300 mA |
| Maximum Breaking Capacity | 50 kA |
| Rated Frequency (f) | 50 … 60 Hz |
| Power Loss | 55.1 W |
| Material Compliance | |
| RoHS Declaration | 9AKK108468A1488 |
| RoHS Information | Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019 |
| RoHS Date | 20230517 |
| REACH Declaration | 9AKK108470A9089 |
| REACH Information | True - contains substances > 0.1 mass percentage |
| REACH Date | 20250313 |
| Conflict Minerals Reporting Template (CMRT) | 9AKK108468A3363 |
| WEEE Category | 5. Small Equipment (No External Dimension More Than 50 cm) |
| WEEE B2C / B2B | Business To Business |
| Dimensions | |
| Product Net Width | 227.5 mm |
| Product Net Height | 108.2 mm |
| Product Net Depth / Length | 82.3 mm |
| Product Net Weight | 1757 g |
| Ordering | |
| Package Level 1 Units | box 1 piece |
| Package Level 1 Gross Weight | 1757 g |
| E-Number (Norway) | 1628653 |
| Certificates and Declarations | |
| Declaration of Conformity - CE | 9AKK108468A1488 |
| Declaration of Conformity - UKCA | 9AKK108468A1489 |
| Installation | |
| Instructions and Manuals | 9AKK108467A9515 |
| Popular Downloads | |
| Data Sheet, Technical Information | 9AKK107991A8329 |
| External Classifications and Standards | |
| ETIM 9 | EC002281 - Distributor assembly with combination RCCB/MCB |
| ETIM 10 | EC002281 - Distributor assembly with combination RCCB/MCB |
| Standards | IEC 60947-2 |
| Feature Name | Feature Value |
|---|---|
| Rated current (EF000227) | 125 A |
| Rated fault current (EF002358) | 300 mA |
| Number of protected poles (EF005548) | 4 |
| Concurrently switching neutral conductor (EF005997) | Yes |
| Release characteristic (EF000889) | B |
| Breaking capacity (EF005617) | 50 kA |
| Number of earth leakage circuit breakers (EF005540) | 1 |
| Height (EF000040) | 108.2 mm |
| Width (EF000008) | 227.5 mm |
| Depth (EF000049) | 82.3 mm |