View larger
2CCG001222R0001 ABB Int. aut. S803P-B125 3p 125A B 50kA
2CCG001222R0001
001222
ABB
1 Pcs.
Automation > Miniature circuit breaker (MCB)
Industrial
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
Abb 2CCG001222R0001 is a heavy-duty automatic circuit breaker designed to manage high fault currents and protect industrial electrical systems from dangerous overcurrents. It delivers reliable isolation and switching performance in demanding energy distribution setups.
Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- ABB EcoSolutions: Yes
- EcoSolutions Profile: 9AKK108471A1082
- Recyclability Rate of the Product acc. to EN45555: Design for Closing Resource Loops - Standard EN45555 - 86.29 %
- ABB Site Meeting Group Waste To Landfill Target: No non-hazardous waste is sent to a landfill
- End Of Life Disassembling Instructions: 9AKK108470A2575
- Environmental Product Declaration - EPD: 9AKK108470A1695
- Rated Ultimate Short-Circuit Breaking Capacity (I cu ): (415 V AC) 50 kA
- Rated Service Short-Circuit Breaking Capacity (I cs ): (240 / 415 V AC) 40 kA
- Contact Position Indication: ON / OFF / TRIP
- Energy Limiting Class: 3
- Number of Protected Poles: 3
- Number of Poles: 3P
- Tightening Torque: 3.5 N·m
- Release Type: B
- Actuator Marking: I / O
- Recommended Screw Driver: Pozidriv 2
More info
▲| ABB EcoSolutions | |
|---|---|
| ABB EcoSolutions | Yes |
| EcoSolutions Profile | 9AKK108471A1082 |
| Recyclability Rate of the Product acc. to EN45555 | Design for Closing Resource Loops - Standard EN45555 - 86.29 % |
| ABB Site Meeting Group Waste To Landfill Target | No non-hazardous waste is sent to a landfill |
| End Of Life Disassembling Instructions | 9AKK108470A2575 |
| Environmental Product Declaration - EPD | 9AKK108470A1695 |
| 9AKK108470A1696 | |
| Technical | |
| Rated Ultimate Short-Circuit Breaking Capacity (Icu) | (415 V AC) 50 kA |
| (440 V AC) 30 kA | |
| (500 V AC) 10 kA | |
| (690 V AC) 4.5 kA | |
| (375 V DC) 30 kA | |
| Rated Service Short-Circuit Breaking Capacity (Ics) | (240 / 415 V AC) 40 kA |
| Contact Position Indication | ON / OFF / TRIP |
| Energy Limiting Class | 3 |
| Number of Protected Poles | 3 |
| Number of Poles | 3P |
| Tightening Torque | 3.5 N·m |
| Release Type | B |
| Actuator Marking | I / O |
| Recommended Screw Driver | Pozidriv 2 |
| Accessories Available | Yes |
| Connecting Capacity | Flexible 1...50 mm² |
| Rigid 1...70 mm² | |
| Wire Stripping Length | 19 mm |
| Electrical | |
| Tripping Characteristic | B |
| Rated Operational Voltage | acc. to IEC 60898-1 400 V AC |
| acc. to IEC 60947-2 690 V AC | |
| Rated Insulation Voltage (Ui) | acc. to IEC/EN 60664-1 690 V |
| Rated Impulse Withstand Voltage (Uimp) | 6 kV |
| Input Voltage Type | AC/DC |
| Rated Current (In) | 125 A |
| Rated Short-Circuit Capacity | (400 V AC) 15 kA |
| Frequency (f) | 50/60 Hz |
| Rated Frequency (f) | 50/60 Hz |
| Power Loss | Total 28.2 W |
| at Rated Operating Conditions per Pole 9.4 W | |
| Overvoltage Category | III |
| Material Compliance | |
| RoHS Declaration | 9AKK108468A0836 |
| RoHS Information | Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019 |
| RoHS Date | 20230505 |
| REACH Declaration | 9AKK108470A9089 |
| REACH Information | False - does not contain substances > 0.1 mass percentage |
| REACH Date | 20250313 |
| Conflict Minerals Reporting Template (CMRT) | 9AKK108468A3363 |
| WEEE Category | 5. Small Equipment (No External Dimension More Than 50 cm) |
| WEEE B2C / B2B | Business To Business |
| Environmental | |
| Ambient Air Temperature | Operation -40 ... 70 °C |
| Storage -40 ... 70 °C | |
| Reference Ambient Air Temperature | 30 °C |
| Degree of Protection | IP20 |
| Pollution Degree | 3 |
| Dimensions | |
| Width in Number of Modular Spacings | 5 |
| Product Net Width | 90.0 mm |
| Product Net Height | 95.0 mm |
| Product Net Depth / Length | 82.5 mm |
| Product Net Weight | 765 g |
| Built-In Depth (t2) | 82.5 mm |
| Engineering | |
| EPLAN Data | 9AAF605105_EPLAN |
| Ordering | |
| Package Level 1 Units | box 1 piece |
| Package Level 1 Gross Weight | 800 g |
| E-Number (Finland) | 3217351 |
| E-Number (Norway) | 1629246 |
| E-Number (Sweden) | 2101417 |
| Certificates and Declarations | |
| CB Certificate | 9AKK108468A1243 |
| CCC Certificate | 9AKK108468A8539 |
| CEBEC Certificate | 9AKK108468A1244 |
| Declaration of Conformity - CE | 9AKK108468A0836 |
| Declaration of Conformity - UKCA | 9AKK108468A0837 |
| DNV GL Certificate | 2CCC413018D0201 |
| ESTI Certificate | 9AKK108468A2302 |
| KC Certificate | 9AKK108468A8755 |
| LR Certificate | 9AKK108468A8541 |
| RINA Certificate | 9AKK108469A1379 |
| VDE Certificate | 9AKK108468A6941 |
| Installation | |
| Instructions and Manuals | 2CCC413016M0008 |
| Mounting on DIN Rail | TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715 |
| TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715 | |
| Mounting Position | Any |
| Popular Downloads | |
| Data Sheet, Technical Information | 9AKK108468A9560 |
| 9AKK108468A9561 | |
| 9AKK108468A9562 | |
| External Classifications and Standards | |
| ETIM 9 | EC000042 - Miniature circuit breaker (MCB) |
| ETIM 10 | EC000042 - Miniature circuit breaker (MCB) |
| UNSPSC | 39121603 |
| eClass | V11.0 : 27141901 |
| IDEA Granular Category Code (IGCC) | 4899 >> Miniature circuit breaker (MCB) screw-in model |
| Object Classification Code | F |
| Standards | IEC/EN 60947-2 |
| UL 1077 | |