View larger
1SDA104469R1
104469
ABB
1 Pcs.
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
| ABB EcoSolutions | |
|---|---|
| ABB EcoSolutions | Yes |
| ABB Site Meeting Group Waste To Landfill Target | UL 2799 Zero Waste To Landfill Validation available |
| End Of Life Disassembling Instructions | 9AKK108468A2361 |
| Environmental Product Declaration - EPD | 9AKK108471A0821 |
| Material Compliance | |
| REACH Declaration | 9AKK108466A1425 |
| RoHS Declaration | 9AKK108466A1424 |
| RoHS Information | Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019 |
| Conflict Minerals Reporting Template (CMRT) | 9AKK108467A5658 |
| Toxic Substances Control Act - TSCA | 9AKK108467A8326 |
| SCIP | 5348fa8c-fe92-4541-bffd-cd31033a90ac Italy |
| Simplified SCIP | 0cbb1003-9315-40a9-b179-7624edd821d4 Germany |
| 2e682305-5f0f-4458-b8ab-93def1f07474 Hungary | |
| 2ddd2e81-56a9-4bf1-80df-f7e4aa08eef2 Norway | |
| 723eb9b7-0a6e-4795-aa23-a91790991fa8 Poland | |
| 15699129-99cc-40a3-a5ff-96d4170b5440 Finland | |
| 1e19deff-cd54-4bba-a959-7744be72d54f Sweden | |
| 6117860c-6c93-4b64-b8e1-676a96c601f1 Germany | |
| 0b785035-ebf8-4ed1-a5b9-8478131a05bc Germany | |
| d801f1ee-1cd0-435d-96e6-171d3639ac1d Estonia | |
| f14eaef8-8199-4201-b293-f1b8b78c922f Belgium | |
| 4b636094-fa68-4713-bd7e-9c2412534b9a Denmark | |
| 3c491259-745d-4a5c-89c3-0c3475a11814 Germany | |
| 3f12c98b-398d-4252-8a2b-fefcb3129d81 Germany | |
| 2a7635af-5758-44df-b7a9-8da18ddcde62 Poland | |
| c3572713-2153-4759-b699-d8bf68d500a7 Poland | |
| 69cf4a29-c648-4b72-a67f-3f18ee02d22f Czech Republic | |
| 58738951-32af-43f3-a4c7-71b8c6b7ef8b Netherlands | |
| c1a86b49-4909-41e7-a57b-f44975b601e5 Croatia | |
| 255ade06-bb09-4a85-b983-5c003a114734 Portugal | |
| b1eed294-0734-409b-859b-22087937972f Bulgaria | |
| 43c63760-5d3b-4f02-bba2-ee0c4e70bbf9 Sweden | |
| 18001df4-8d38-4e06-a27d-6993e0eb0c90 Greece | |
| 59b1b652-0d1b-4151-802d-cab4813e04a6 France | |
| 0a0b4591-52dc-4685-8a18-87f73887c687 Hungary | |
| 99926840-59c2-4c40-a883-7d0c2cfce4cc Spain | |
| f1633e98-84ec-4d82-abbd-25a10c32fb27 Belgium | |
| 25e3b476-a88d-4960-9247-515668ba86e6 France | |
| Environmental | |
| Environmental Information | 9AKK108467A6707 |
| Ordering | |
| Order Code US and Canada | 92HREHAF000A000000XX |
| EAN | 8056221026307 |
| Minimum Order Quantity | 1 piece |
| Customs Tariff Number | 85362090 |
| Dimensions | |
| Product Net Width | 317 mm |
| Product Net Height | 425 mm |
| Product Net Depth / Length | 383 mm |
| Product Net Weight | 48 kg |
| Container Information | |
| Package Level 1 Units | box 1 piece |
| Package Level 1 Width | 515 mm |
| Package Level 1 Height | 610 mm |
| Package Level 1 Depth / Length | 515 mm |
| Package Level 1 Gross Weight | 53 kg |
| Package Level 1 EAN | 8056221026307 |
| Additional Information | |
| Product Main Type | SACE Emax 2 |
| Product Name | Air Circuit Breaker |
| Product Type | Air Circuit Breaker |
| Version | W |
| Technical | |
| Current Type | AC |
| Electrical Durability | Ue = 900 V 2000 cycle |
| 30 cycles per hour | |
| Mechanical Durability | 25000 cycle |
| 60 cycles per hour | |
| Number of Poles | 3P |
| Power Loss | 176 W |
| Rated Current (In) | 1250 A |
| Rated Impulse Withstand Voltage (Uimp) | acc. to IEC 60947-2 12 kV |
| Rated Insulation Voltage (Ui) | AC 1000 V |
| Rated Operational Voltage | 900 V AC |
| Rated Service Short-Circuit Breaking Capacity (Ics) | (800 V AC) 65 kA |
| (900 V AC) 65 kA | |
| Rated Short-time Withstand Current Low Voltage (Icw) | for 1 s 65 kA |
| for 3 s 65 kA | |
| Rated Ultimate Short-Circuit Breaking Capacity (Icu) | (800 V AC) 65 kA |
| (900 V AC) 65 kA | |
| Rated Uninterrupted Current (Iu) | 1250 A |
| Rated Voltage (Ur) | 900 V |
| Release | Ekip Touch LSIG |
| Release Type | EL |
| Remarks | E9 |
| Short-Circuit Performance Level | H |
| Standards | IEC |
| Sub-type | E2.2 |
| Suitable for IT Networks | Yes, 900V |
| Terminal Connection Type | Rear flat Horizontal |
| Certificates and Declarations | |
| Data Sheet, Technical Information | 1SDC200023D0209 |
| Declaration of Conformity - CE | 9AKK107680A4888 |
| Instructions and Manuals | 1SDH001000R0002 |
| Instructions and Manuals (Part 2) | 1SDH001316R1002 |
| External Classifications and Standards | |
| ETIM 9 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| ETIM 10 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| Object Classification Code | Q |
| WEEE Category | 5. Small Equipment (No External Dimension More Than 50 cm) |
| eClass | V11.1 : 27370409 |
| Feature Name | Feature Value |
|---|---|
| Rated permanent current Iu (EF001389) | 1250 A |
| Rated voltage (EF003977) | 900 V |
| Overload release current setting (EF002336) | 1250 A |
| Adjustment range short-term delayed short-circuit release (EF007129) | 12500 A |
| Adjustment range undelayed short-circuit release (EF007131) | 1875.0 A |
| Integrated earth fault protection (EF007296) | Yes |
| Type of electrical connection of main circuit (EF006819) | Connection at separate chassis part |
| Device construction (EF008240) | Built-in device slide-in technique (withdrawable) |
| Suitable for DIN rail (top hat rail) mounting (EF007250) | No |
| DIN rail (top hat rail) mounting optional (EF008904) | No |
| Number of auxiliary contacts as normally closed contact (EF001377) | 0 |
| Number of auxiliary contacts as normally open contact (EF001376) | 0 |
| Number of auxiliary contacts as change-over contact (EF003531) | 4 |
| With switched-off indicator (EF007006) | Yes |
| With integrated under voltage release (EF001390) | No |
| Number of poles (EF001391) | 3 |
| Position of connection for main current circuit (EF006671) | Connection at separate chassis part |
| Type of control element (EF006976) | Push button |
| Complete device with protection unit (EF008906) | Yes |
| Motor drive integrated (EF006697) | No |
| Motor drive optional (EF007386) | Yes |
| Degree of protection (IP) (EF005474) | IP30 |