View larger
1SDA104367R1 ABB E2.2H/E9 2000 Ekip Dip LSI 4p FHR
1SDA104367R1
104367
ABB
1 Pcs.
Automation > Power circuit-breaker for trafo/generator/installation protection
Rack "Megamax-Emax"
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
ABB E2.2H/E9 2000 Ekip Dip LSI 4p FHR is an air circuit breaker designed to manage high-current power distribution and protect industrial networks against electrical faults. Electronic trip units inside these breakers ensure selective fault interruption. Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- ABB EcoSolutions: Yes
- ABB Site Meeting Group Waste To Landfill Target: UL 2799 Zero Waste To Landfill Validation available
- End Of Life Disassembling Instructions: 9AKK108468A2361
- Environmental Product Declaration - EPD: 9AKK108471A0821
- Extended Product Lifetime: Lifetime Extension Services are Offered
- REACH Declaration: 9AKK108466A1425
- RoHS Declaration: 9AKK108466A1424
- RoHS Information: Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
- Conflict Minerals Reporting Template (CMRT): 9AKK108467A5658
- Toxic Substances Control Act - TSCA: 9AKK108467A8326
- SCIP: 18fcf107-aec2-4ce5-b3f3-9679a9983173 Italy
- Simplified SCIP: 91b63614-cf0a-483d-b425-d6073d3de4c7 Croatia
- Environmental Information: 9AKK108467A6707
- Order Code US and Canada: 9BHTEKBB000A000000XX
- EAN: 8015644064471
- Minimum Order Quantity: 1 piece
More info
▲| ABB EcoSolutions | |
|---|---|
| ABB EcoSolutions | Yes |
| ABB Site Meeting Group Waste To Landfill Target | UL 2799 Zero Waste To Landfill Validation available |
| End Of Life Disassembling Instructions | 9AKK108468A2361 |
| Environmental Product Declaration - EPD | 9AKK108471A0821 |
| Extended Product Lifetime | Lifetime Extension Services are Offered |
| Material Compliance | |
| REACH Declaration | 9AKK108466A1425 |
| RoHS Declaration | 9AKK108466A1424 |
| RoHS Information | Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019 |
| Conflict Minerals Reporting Template (CMRT) | 9AKK108467A5658 |
| Toxic Substances Control Act - TSCA | 9AKK108467A8326 |
| SCIP | 18fcf107-aec2-4ce5-b3f3-9679a9983173 Italy |
| Simplified SCIP | 91b63614-cf0a-483d-b425-d6073d3de4c7 Croatia |
| 44981e4e-c838-492e-a4d6-872d1de5331c Sweden | |
| e1c60f24-d138-43f7-9a6c-3761d260af19 Netherlands | |
| 8640baec-092f-4c5b-8f29-865396200649 Finland | |
| 76fb96e6-82a7-4b42-855b-864f63862adb Portugal | |
| 3a7da235-6376-4dc6-9f44-7c1cb503b684 Germany | |
| 1ba5bf03-1c78-4bbe-8c52-f12eaf99a83d Germany | |
| e8d8c96b-2ee4-4742-a4e1-e001922857f1 Norway | |
| 9da2b0ec-049f-4038-b50f-c85bb6af2043 France | |
| 2e068648-d7f3-4c3d-99ab-b864a6117124 Bulgaria | |
| 7188ed21-3fda-4f4e-a76e-3b3e6b3b1b20 Hungary | |
| 9be66ac5-fa98-45e5-a994-88a3c23feff1 Germany | |
| 3000cd07-bb20-432c-9be1-b7e5b82e2b64 Germany | |
| 81c9e9cb-80d7-43fe-bbc8-3101be001827 Poland | |
| b225a965-dbb6-42ad-9af8-11b699a8e9e6 Belgium | |
| e1c60f24-d138-43f7-9a6c-3761d260af19 Netherlands | |
| f7ca735d-8115-4ed5-a8dc-00674161e675 Greece | |
| 76fb96e6-82a7-4b42-855b-864f63862adb Portugal | |
| 70633484-f1b0-425a-9861-de722e25a5ba Poland | |
| 1058de68-7e78-4f03-a90e-b6525e26f49c Spain | |
| 4447c0f2-d41c-47d1-8b22-85fdb5d7007e France | |
| 026bcb23-582e-4d3e-a23f-467d2675ac48 Hungary | |
| b225a965-dbb6-42ad-9af8-11b699a8e9e6 Belgium | |
| edc42d91-cdf7-4975-a742-8904a4f06831 Poland | |
| 9da2b0ec-049f-4038-b50f-c85bb6af2043 France | |
| 26b29ddc-4b15-4c41-a57e-560e5f3c37e1 Sweden | |
| 3000cd07-bb20-432c-9be1-b7e5b82e2b64 Germany | |
| 9be66ac5-fa98-45e5-a994-88a3c23feff1 Germany | |
| 44981e4e-c838-492e-a4d6-872d1de5331c Sweden | |
| 76f7f5f3-1948-4bcd-bb82-548697e9163f Estonia | |
| 1058de68-7e78-4f03-a90e-b6525e26f49c Spain | |
| 4447c0f2-d41c-47d1-8b22-85fdb5d7007e France | |
| 70633484-f1b0-425a-9861-de722e25a5ba Poland | |
| f7d74a4e-4fc7-4a2e-8961-c8a14463b65a Czech Republic | |
| 7188ed21-3fda-4f4e-a76e-3b3e6b3b1b20 Hungary | |
| 76f7f5f3-1948-4bcd-bb82-548697e9163f Estonia | |
| 23fe308f-90be-4c6b-b700-0f80c3519e5c Belgium | |
| 91b63614-cf0a-483d-b425-d6073d3de4c7 Croatia | |
| cb899487-395e-48a9-84a3-be730912d1c7 Germany | |
| 8640baec-092f-4c5b-8f29-865396200649 Finland | |
| 81c9e9cb-80d7-43fe-bbc8-3101be001827 Poland | |
| 40f01ab4-0404-48d1-a3a3-7d70d854bbc9 Denmark | |
| 026bcb23-582e-4d3e-a23f-467d2675ac48 Hungary | |
| f7ca735d-8115-4ed5-a8dc-00674161e675 Greece | |
| f7d74a4e-4fc7-4a2e-8961-c8a14463b65a Czech Republic | |
| edc42d91-cdf7-4975-a742-8904a4f06831 Poland | |
| 1ba5bf03-1c78-4bbe-8c52-f12eaf99a83d Germany | |
| 26b29ddc-4b15-4c41-a57e-560e5f3c37e1 Sweden | |
| 40f01ab4-0404-48d1-a3a3-7d70d854bbc9 Denmark | |
| 3a7da235-6376-4dc6-9f44-7c1cb503b684 Germany | |
| cb899487-395e-48a9-84a3-be730912d1c7 Germany | |
| 2e068648-d7f3-4c3d-99ab-b864a6117124 Bulgaria | |
| 23fe308f-90be-4c6b-b700-0f80c3519e5c Belgium | |
| e8d8c96b-2ee4-4742-a4e1-e001922857f1 Norway | |
| Environmental | |
| Environmental Information | 9AKK108467A6707 |
| Ordering | |
| Order Code US and Canada | 9BHTEKBB000A000000XX |
| EAN | 8015644064471 |
| Minimum Order Quantity | 1 piece |
| Customs Tariff Number | 85362090 |
| Dimensions | |
| Product Net Width | 366 mm |
| Product Net Height | 371 mm |
| Product Net Depth / Length | 270 mm |
| Product Net Weight | 53 kg |
| Container Information | |
| Package Level 1 Units | box 1 piece |
| Package Level 1 Width | 515 mm |
| Package Level 1 Height | 610 mm |
| Package Level 1 Depth / Length | 515 mm |
| Package Level 1 Gross Weight | 53 kg |
| Package Level 1 EAN | 8015644064471 |
| Additional Information | |
| Product Main Type | SACE Emax 2 |
| Product Name | Air Circuit Breaker |
| Product Type | Air Circuit Breaker |
| Version | F |
| Technical | |
| Current Type | AC |
| Electrical Durability | Ue = 900 V 2000 cycle |
| 30 cycles per hour | |
| Mechanical Durability | 25000 cycle |
| 60 cycles per hour | |
| Number of Poles | 4P |
| Power Loss | 212 W |
| Rated Current (In) | 2000 A |
| Rated Impulse Withstand Voltage (Uimp) | acc. to IEC 60947-2 12 kV |
| Rated Insulation Voltage (Ui) | AC 1000 V |
| Rated Operational Voltage | 900 V AC |
| Rated Service Short-Circuit Breaking Capacity (Ics) | (800 V AC) 65 kA |
| (900 V AC) 65 kA | |
| Rated Short-time Withstand Current Low Voltage (Icw) | for 1 s 65 kA |
| for 3 s 65 kA | |
| Rated Ultimate Short-Circuit Breaking Capacity (Icu) | (800 V AC) 65 kA |
| (900 V AC) 65 kA | |
| Rated Uninterrupted Current (Iu) | 2000 A |
| Rated Voltage (Ur) | 900 V |
| Release | Ekip Dip LSI |
| Release Type | EL |
| Remarks | E9 |
| Short-Circuit Performance Level | H |
| Standards | IEC |
| Sub-type | E2.2 |
| Suitable for IT Networks | Yes, 900V |
| Terminal Connection Type | Rear flat Horizontal |
| Certificates and Declarations | |
| Data Sheet, Technical Information | 1SDC200023D0209 |
| Declaration of Conformity - CE | 9AKK107680A4888 |
| Instructions and Manuals | 1SDH001000R0002 |
| External Classifications and Standards | |
| ETIM 9 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| ETIM 10 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| Object Classification Code | Q |
| WEEE Category | 5. Small Equipment (No External Dimension More Than 50 cm) |
| eClass | V11.1 : 27370409 |