View larger
1SDA101196R1 ABB XT7H 1250 Ekip Touch Meas.LSIG 1250 4pFF
1SDA101196R1
101196
ABB
1 Pcs.
Automation > Power circuit-breaker for trafo/generator/installation protection
Molded case "Isomax-Tmax"
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
ABB 1SDA101196R1 circuit breaker provides high-capacity current monitoring and interruption for complex power systems. Industrial distribution networks depend on such precision trip units to maintain system integrity under heavy electrical loads.
Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- ABB EcoSolutions: Yes
- ABB Site Meeting Group Waste To Landfill Target: UL 2799 Zero Waste To Landfill Validation available
- End Of Life Disassembling Instructions: 9AKK108468A2357
- Environmental Product Declaration - EPD: 9AKK108468A1895
- Extended Product Lifetime: Product Modularity
- Recyclability Rate of the Product acc. to EN45555: Design for Closing Resource Loops - Standard EN45555 - 64.1 %
- REACH Declaration: 9AKK108466A1425
- RoHS Declaration: 9AKK108466A1424
- RoHS Information: Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
- Conflict Minerals Reporting Template (CMRT): 9AKK108467A5658
- Toxic Substances Control Act - TSCA: 9AKK108467A8326
- SCIP: 24e058ef-832e-4ee2-92be-39162275f305 Italy
- Simplified SCIP: 0a303f50-b412-4dd9-95fb-8c883509bad0 Netherlands
- Ambient Air Temperature: Operation -40 ... 125 °C
- Environmental Information: 9AKK108467A6707
- Order Code US and Canada: XT7HE412ESFF000XXX
More info
▲| ABB EcoSolutions | |
|---|---|
| ABB EcoSolutions | Yes |
| ABB Site Meeting Group Waste To Landfill Target | UL 2799 Zero Waste To Landfill Validation available |
| End Of Life Disassembling Instructions | 9AKK108468A2357 |
| Environmental Product Declaration - EPD | 9AKK108468A1895 |
| 9AKK108468A4404 | |
| Extended Product Lifetime | Product Modularity |
| Recyclability Rate of the Product acc. to EN45555 | Design for Closing Resource Loops - Standard EN45555 - 64.1 % |
| Material Compliance | |
| REACH Declaration | 9AKK108466A1425 |
| RoHS Declaration | 9AKK108466A1424 |
| RoHS Information | Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019 |
| Conflict Minerals Reporting Template (CMRT) | 9AKK108467A5658 |
| Toxic Substances Control Act - TSCA | 9AKK108467A8326 |
| SCIP | 24e058ef-832e-4ee2-92be-39162275f305 Italy |
| Simplified SCIP | 0a303f50-b412-4dd9-95fb-8c883509bad0 Netherlands |
| 29cf93aa-163f-4853-a74d-7d87ad642e6b Croatia | |
| 03ac0c4d-2ed6-4259-ab58-d2b22f156d6d Belgium | |
| 8d1afa7c-6e56-4d9e-b0ea-fd77af3426a4 Bulgaria | |
| 6ae49f6e-7ba9-49b9-8c8d-7b43ff62159b France | |
| 45c9eed6-e7e3-4e2a-9a19-f2984bf432ef Sweden | |
| 7c682a2d-9f4e-4f90-ae98-f6c6442f2064 Poland | |
| 856004b8-bcba-41da-b13c-abe8aaf9f112 France | |
| 88773c1b-f79d-4c03-8d97-ebe899375ebf Portugal | |
| c3221916-5aea-4cf2-bea1-1d003f7b5b46 Germany | |
| 7cd9cb23-31d3-4f1f-98d0-680ffc2a4655 Spain | |
| 53b5adb9-4381-468e-9dea-e54e0e3eb291 Hungary | |
| 04148ad7-8041-495d-b099-86a02986b353 Germany | |
| daf39b90-73fa-4584-9e41-40792f524005 Poland | |
| a67cfef6-de18-41ca-b6bb-ab432b6336ba Norway | |
| 64ad1203-8f8b-467c-8a9b-5232f999a720 Finland | |
| 94d49f3d-fa7a-4b1e-b838-77dda8d6234e Germany | |
| c44d8792-ebde-4cfa-b72a-4bb44d78b68d Belgium | |
| af12a80e-db68-4951-a658-800e5a5548fa Germany | |
| aaffda17-6a6c-48b0-bee6-5cf96ab70d01 Denmark | |
| 6506a995-c679-4137-b7ff-f480344739be Germany | |
| 21984119-1d20-4f85-b65d-33070389e508 Poland | |
| be8d74d8-dda9-4ad3-9dea-67877c71cd34 Czech Republic | |
| 29ac8c9a-552e-4e51-9e0b-02ffc5c58547 Greece | |
| f8ffdd51-45df-4a67-8e65-e3a27d75a72b Estonia | |
| c06f8e2c-3c06-4219-8aff-d6d184ed8371 Sweden | |
| c46dee05-c31d-4d55-8415-212fedd42b19 Hungary | |
| Environmental | |
| Ambient Air Temperature | Operation -40 ... 125 °C |
| Environmental Information | 9AKK108467A6707 |
| Ordering | |
| Order Code US and Canada | XT7HE412ESFF000XXX |
| EAN | 8056221014991 |
| Minimum Order Quantity | 1 piece |
| Customs Tariff Number | 85362090 |
| Dimensions | |
| Product Net Width | 280 mm |
| Product Net Height | 268 mm |
| Product Net Depth / Length | 166 mm |
| Product Net Weight | 12.5 kg |
| Container Information | |
| Package Level 1 Units | box 1 piece |
| Package Level 1 Width | 360 mm |
| Package Level 1 Height | 350 mm |
| Package Level 1 Depth / Length | 360 mm |
| Package Level 1 Gross Weight | 14 kg |
| Package Level 1 EAN | 8056221014991 |
| Additional Information | |
| Circuit Breaker Type to be Associated | Power Distribution |
| Product Main Type | SACE Tmax XT |
| Product Name | Moulded Case Circuit Breaker |
| Product Type | Automatic Circuit Breaker |
| Version | F |
| CAD Dimensional Drawing | 1SDH002065A1390 |
| 1SDH002065A1338 | |
| Technical | |
| Current Type | AC |
| Electrical Durability | 3000 cycle |
| 60 cycles per hour | |
| Mechanical Durability | 10000 cycle |
| 60 cycles per hour | |
| Number of Poles | 4P |
| Order Multiple | 1 piece |
| Power Loss | at Rated Operating Conditions per Pole 57 W |
| Rated Current (In) | 1250 A |
| Rated Impulse Withstand Voltage (Uimp) | 8 kV |
| Rated Insulation Voltage (Ui) | 1000 V |
| Rated Operational Voltage | 690 V AC |
| Rated Service Short-Circuit Breaking Capacity (Ics) | (220 V AC) 100 kA |
| (230 V AC) 100 kA | |
| (240 V AC) 100 kA | |
| (380 V AC) 70 kA | |
| (415 V AC) 70 kA | |
| (440 V AC) 65 kA | |
| (500 V AC) 50 kA | |
| (525 V AC) 50 kA | |
| (690 V AC) 42 kA | |
| Rated Short-time Withstand Current Low Voltage (Icw) | 20 kA |
| Rated Ultimate Short-Circuit Breaking Capacity (Icu) | (220 V AC) 100 kA |
| (230 V AC) 100 kA | |
| (240 V AC) 100 kA | |
| (380 V AC) 70 kA | |
| (415 V AC) 70 kA | |
| (440 V AC) 65 kA | |
| (500 V AC) 50 kA | |
| (525 V AC) 50 kA | |
| (690 V AC) 42 kA | |
| Rated Uninterrupted Current (Iu) | 1250 A |
| Release | Ekip Touch Measuring LSIG |
| Release Type | EL |
| Short-Circuit Performance Level | H |
| Standards | IEC60947-2 |
| Sub-type | XT7 |
| Terminal Connection Type | Front |
| Certificates and Declarations | |
| Data Sheet, Technical Information | 1SDC210100D0206 |
| 1SDC210099D0206 | |
| Declaration of Conformity - CE | 9AKK107046A9648 |
| EU Data Act Compliance Declaration | 1SDH002560A1001 |
| Mechanical Drawings | 1SDH002013A1101 |
| Wiring Diagram | 1SDM000002A1001 |
| Instructions and Manuals | 1SDH002013A1001 |
| 1SDH002013A1002 | |
| 1SDH001821A1001 | |
| External Classifications and Standards | |
| ETIM 9 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| ETIM 10 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| Object Classification Code | Q |
| WEEE Category | 5. Small Equipment (No External Dimension More Than 50 cm) |
| eClass | V11.1 : 27370409 |