View larger
1SDA100991R1 ABB XT7L 1000 Ekip M Dip I In 1000A 3p F F
1SDA100991R1
100991
ABB
1 Pcs.
Automation > Power circuit-breaker for trafo/generator/installation protection
Molded case "Isomax-Tmax"
Product condition, packaging, certifications and applicable manufacturer warranty terms are confirmed with the quotation.
Request a Quote
Pricing and availability are confirmed for each enquiry. Send this part and we will reply with price and lead time.
Request QuoteProduct Overview
Engineered for high-power motor and distribution protection, the Abb XT7L 1000 Ekip M Dip I In 1000A 3p F F moulded case circuit breaker interrupts fault currents effectively. It is commonly integrated into demanding industrial switchboards to maintain operational safety. Pricing, availability and lead time are confirmed per enquiry through an RFQ.
- ABB EcoSolutions: Yes
- ABB Site Meeting Group Waste To Landfill Target: UL 2799 Zero Waste To Landfill Validation available
- End Of Life Disassembling Instructions: 9AKK108468A2357
- Environmental Product Declaration - EPD: 9AKK108468A1895
- Extended Product Lifetime: Product Modularity
- Recyclability Rate of the Product acc. to EN45555: Design for Closing Resource Loops - Standard EN45555 - 64.1 %
- REACH Declaration: 9AKK108466A1425
- RoHS Declaration: 9AKK108466A1424
- RoHS Information: Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
- Conflict Minerals Reporting Template (CMRT): 9AKK108467A5658
- Toxic Substances Control Act - TSCA: 9AKK108467A8326
- SCIP: a9529a46-10c1-4897-a110-ec6ccffed39f China
- Simplified SCIP: 77dee3b0-2981-4ac6-ac68-baffac1aa546 France
- Ambient Air Temperature: Operation -40 ... 125 °C
- Environmental Information: 9AKK108467A6707
- Order Code US and Canada: XT7LE310DKFF000XXX
More info
▲| ABB EcoSolutions | |
|---|---|
| ABB EcoSolutions | Yes |
| ABB Site Meeting Group Waste To Landfill Target | UL 2799 Zero Waste To Landfill Validation available |
| End Of Life Disassembling Instructions | 9AKK108468A2357 |
| Environmental Product Declaration - EPD | 9AKK108468A1895 |
| 9AKK108468A4404 | |
| Extended Product Lifetime | Product Modularity |
| Recyclability Rate of the Product acc. to EN45555 | Design for Closing Resource Loops - Standard EN45555 - 64.1 % |
| Material Compliance | |
| REACH Declaration | 9AKK108466A1425 |
| RoHS Declaration | 9AKK108466A1424 |
| RoHS Information | Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019 |
| Conflict Minerals Reporting Template (CMRT) | 9AKK108467A5658 |
| Toxic Substances Control Act - TSCA | 9AKK108467A8326 |
| SCIP | a9529a46-10c1-4897-a110-ec6ccffed39f China |
| Simplified SCIP | 77dee3b0-2981-4ac6-ac68-baffac1aa546 France |
| 42905641-4aed-41aa-aa91-cc16dcfa9b18 Denmark | |
| 89d903fb-1243-44ce-9aef-9c447af6b52d Norway | |
| f8081e1b-e571-464b-8941-62f33fe341a8 Belgium | |
| c8e9a6c7-264e-4b4b-843d-ebb4c8280634 Croatia | |
| 2da01f29-d2bb-4f73-b7ed-236fedbeac8e Hungary | |
| c428f71e-a95a-44a5-81e0-693586f14140 Greece | |
| 9106a157-a302-4f8d-a7bc-dc6ac353beba Germany | |
| 57b22d7b-73c9-4ba2-86d4-d2cdb4982b35 Sweden | |
| 7de00a82-74f6-4c5d-94e6-1eec78c94796 Poland | |
| 69bf3812-dc09-48ed-9270-09418bfcfeae Spain | |
| cee9c869-2c27-4db5-92a6-56aa3097a167 Poland | |
| 406e83ad-6fe7-437b-803a-0fba96b16d01 Estonia | |
| 827e8021-3bf1-4c22-813d-4ffbb94f1409 Hungary | |
| cf7c96e6-bfa0-4ed5-85bb-ce132a824f51 Bulgaria | |
| 0e3a4f99-ff6e-4c4f-8423-79ed3358c4cf Portugal | |
| c1d492ca-94d4-4bfc-bdc8-429c990db46b Germany | |
| 5b500577-54c5-4b07-8f6a-a7e9552c0fc5 Sweden | |
| 2064bbe2-dd5c-44e9-8e2e-22e51dcd408a Poland | |
| f044e7dc-f398-4942-a5e9-7d3e2aad0a82 Czech Republic | |
| 8f1cb283-1e72-46e5-a9cf-0932a718c9d3 Netherlands | |
| d3260be2-9dd5-4952-8079-8859d35afa45 Belgium | |
| 628fa5aa-6bfc-4950-8720-57c2fd9bd8fa France | |
| 0d4fad5e-7d7d-4ba1-a880-fc9dfbb41c85 Germany | |
| d09490f1-6dc4-439e-a375-4b1ee3cb4a88 Finland | |
| a950e8d1-2f9c-4ad4-ad10-47af10735692 Germany | |
| fa4a0d69-0477-409d-9552-ce57478e2836 Germany | |
| Environmental | |
| Ambient Air Temperature | Operation -40 ... 125 °C |
| Environmental Information | 9AKK108467A6707 |
| Ordering | |
| Order Code US and Canada | XT7LE310DKFF000XXX |
| E-Number (Norway) | 4380688 |
| EAN | 8056221010450 |
| Minimum Order Quantity | 1 piece |
| Customs Tariff Number | 85362090 |
| Dimensions | |
| Product Net Width | 210 mm |
| Product Net Height | 268 mm |
| Product Net Depth / Length | 166 mm |
| Product Net Weight | 9.7 kg |
| Container Information | |
| Package Level 1 Units | box 1 piece |
| Package Level 1 Width | 280 mm |
| Package Level 1 Height | 350 mm |
| Package Level 1 Depth / Length | 360 mm |
| Package Level 1 Gross Weight | 11.2 kg |
| Package Level 1 EAN | 8056221010450 |
| Additional Information | |
| Circuit Breaker Type to be Associated | Motor Protection |
| Product Main Type | SACE Tmax XT |
| Product Name | Moulded Case Circuit Breaker |
| Product Type | Automatic Circuit Breaker |
| Version | F |
| CAD Dimensional Drawing | 1SDH002065A1336 |
| 1SDH002065A1338 | |
| Technical | |
| Current Type | AC |
| Electrical Durability | 3000 cycle |
| 60 cycles per hour | |
| Mechanical Durability | 10000 cycle |
| 60 cycles per hour | |
| Number of Poles | 3P |
| Order Multiple | 1 piece |
| Power Loss | at Rated Operating Conditions per Pole 37 W |
| Rated Current (In) | 1000 A |
| Rated Impulse Withstand Voltage (Uimp) | 8 kV |
| Rated Insulation Voltage (Ui) | 1000 V |
| Rated Operational Voltage | 690 V AC |
| Rated Service Short-Circuit Breaking Capacity (Ics) | (220 V AC) 200 kA |
| (230 V AC) 200 kA | |
| (240 V AC) 200 kA | |
| (380 V AC) 120 kA | |
| (415 V AC) 120 kA | |
| (440 V AC) 100 kA | |
| (500 V AC) 85 kA | |
| (525 V AC) 65 kA | |
| (690 V AC) 50 kA | |
| Rated Short-time Withstand Current Low Voltage (Icw) | 20 kA |
| Rated Ultimate Short-Circuit Breaking Capacity (Icu) | (220 V AC) 200 kA |
| (230 V AC) 200 kA | |
| (240 V AC) 200 kA | |
| (380 V AC) 120 kA | |
| (415 V AC) 120 kA | |
| (440 V AC) 100 kA | |
| (500 V AC) 85 kA | |
| (525 V AC) 65 kA | |
| (690 V AC) 50 kA | |
| Rated Uninterrupted Current (Iu) | 1000 A |
| Release | Ekip M Dip I |
| Release Type | EL |
| Short-Circuit Performance Level | L |
| Standards | IEC60947-2 |
| Sub-type | XT7 |
| Terminal Connection Type | Front |
| Certificates and Declarations | |
| Data Sheet, Technical Information | 1SDC210100D0206 |
| 1SDC210099D0206 | |
| Declaration of Conformity - CE | 9AKK107046A9648 |
| EU Data Act Compliance Declaration | 1SDH002560A1001 |
| Mechanical Drawings | 1SDH002013A1101 |
| Wiring Diagram | 1SDM000002A1001 |
| Instructions and Manuals | 1SDH002013A1001 |
| 1SDH002013A1002 | |
| External Classifications and Standards | |
| ETIM 9 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| ETIM 10 | EC000228 - Power circuit-breaker for trafo/generator/installation protection |
| Object Classification Code | Q |
| WEEE Category | 5. Small Equipment (No External Dimension More Than 50 cm) |
| eClass | V11.1 : 27370409 |